Important Safety Notice

3

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

NOT FOR USE IN OUTDOOR COOKING ENVIRONMENTS.

CAUTION

To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,

attics, crawl spaces or garages.

OPERATION

Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers 

and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, 

maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to 

negligence and the warranty of the unit automatically expires due to improper maintenance.

*NOTE: Please check www.brisasrangehoods.com for revisions before doing any custom work.

ELECTRICAL REQUIREMENTS

Important:

Observe all governing codes and ordinances.
It is the customer’s responsibility:

-  To contact a qualified electrical installer.

-  To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 

latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and 

all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the 

ground path is adequate.
Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure the range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269

 

** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit 

protected by a 15 or 20 ampere circuit breaker or time delay fuse.  Wiring must be 2 wire with ground.  Please also refer to 

Electrical Diagram on product.

A cable locking connector (not supplied) might also be required by local codes.  Check with local requirements, purchase 

and install appropriate connector if necessary.
BML-E30BG - Max. 325 Watts, 2.7 Amps
BML-E36BG - Max. 325 Watts, 2.7 Amps

Cancer and Reproductive Harm - www.P65Warnings.ca.gov

WARNING

Prop. 65 Warning for California Residents

Содержание brisas BML-E30BG

Страница 1: ...Use Care and Installation Guide Model number Serial Number OCT20 0301 XP022528 1 BML E30BG BML E36BG...

Страница 2: ......

Страница 3: ...rance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 11 Ductless Recirculating 12 FEATURES CONTROLS Touch Controls 13 MAINTENANCE Hood and Filter Cleaning 14 Lights 15 ACT CONVERSION 16...

Страница 4: ...EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out im...

Страница 5: ...in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances...

Страница 6: ...ARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Duct cover extension accessory Recirculating kit accessory A B Front o...

Страница 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 8: ...d too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s h...

Страница 9: ...s using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options...

Страница 10: ...IDE TOP of HOOD TOP SUPPORT FRAME top view 10 3 8 23 15 16 29 15 16 35 3 16 25 9 16 23 7 8 3 1 2 10 3 4 1 3 4 11 5 8 4 5 8 Min Ducted 28 Min Recirc 29 Maximum 37 top of electrical box 13 3 4 5 1 6 C L...

Страница 11: ...screws 2 screws for each support frame arm FIG A 2 3 Lift support frame assembly up to the ceiling making sure the the word front on the top support frame faces the front of the hood where the contro...

Страница 12: ...support frame FIG F Slide hood towards the narrow end of key holes to lock in place Hand tighten each of the 4 screws to secure hood to bottom of support frame Install 1 4mm x 12mm long safety screw i...

Страница 13: ...If using hood in ductless recirculating mode you must install the air diverter plate to the Top Support Frame prior to assembling the duct covers Turn to page 12 for more details 10 Secure Top Duct Co...

Страница 14: ...ng and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filters charcoal filter brack...

Страница 15: ...and regulations To verify the maximum fan CFM With hood off press and hold the power button for five seconds If all three fan speed indicators illuminate default maximum CFM If two speed level indicat...

Страница 16: ...an cotton cloth or micro fiber cloth and buff in the direction of the stainless steel grain Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to filter out residue...

Страница 17: ...d accessories page for part s and contact information To replace LED light strip 1 Remove aluminum mesh filters 2 Remove light panel by two screws 3 Disconnect LED light strip quick connector 4 Push i...

Страница 18: ...nother clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if your installer enabled ACT With hood off press and hold the p...

Страница 19: ...17 Wiring Diagrams Fan 315W Lamp LED 5W 2 Total Max 325W 2 7A Voltage 120V 60Hz Power consumption UL file number E127334 THERMALLY PROTECTED Model BML E30BG BML E36BG Fan On Off Lights...

Страница 20: ...brating 1 The motor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood 4 The switch...

Страница 21: ...eplacement Parts LED Light Strip 5W Z0B0043 Aluminum Mesh Filter 50200043 Optional Accessories Recirculating Kit BRC 0007 Replacement Charcoal Filter Z0F C094 Duct Cover Extension up to 12 ceiling B1C...

Страница 22: ...ranty All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHAL...