background image

3L9 Extractors

Manual for Installation, Use and Maintenance

Customer Care Department  •  The             Group Ltd.  •  Harby Road  •  Langar  •  Nottinghamshire  •  NG13 9HY

T

 : 01949 862 012   

F

 : 01949 862 003   

E

 : [email protected]   

W

 : www.cda.eu

Passionate about style

Summary of Contents for 3L9

Page 1: ...rs Manual for Installation Use and Maintenance Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style ...

Page 2: ...ty EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services Disposing of a household appliance separately avoids possible negative consequences for the environment and health It also enabl...

Page 3: ... the intensive function is on To cancel the intensive function touch the speed level key and the extractor will return to the previous speed level The timer The extractor is equipped with a timer that allows the extractor to run for 15 minutes before switching off automatically To activate the timer touch key E The timer indicator will show on the centre of the display when the timer is on Please ...

Page 4: ...ol in for two seconds at positions one two or three as shown in figure 4 To turn on the light Press the remote control in to switch on the light to the highest level as shown in figure 5 To cycle through the light settings high medium low off press the remote control in repeatedly To change the battery The battery will last for approximately 12 months depending on usage To change the battery remov...

Page 5: ...must be reset by touching the speed level key for approximately five seconds until the filters indicator light switches off To remove the grease filter follow the steps below Pull open the handle on the grease filter as shown in fig 8 It will release at the handle side Then lower the grease filter to remove it completely To replace the grease filter repeat the steps in reverse Please note Cleaning...

Page 6: ... refit the new bulb taking care not to touch the glass of the bulb Fingerprints will lead to premature failure of the bulb Replacing the ambient lighting side lamps In normal use the LED ambient lighting should not require replacement and is intended to last the lifetime of the product In the event that these lights fail to operate please contact our service department for repair Fig 10 F F G G B ...

Page 7: ...t should be measured from the top of the hotplates or burners Where the extractor is to be installed above a non CDA hob the instructions supplied with the hob may dictate that the height required above the hob is greater than 650mm IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm Mounting The Extractor 1 Using the s...

Page 8: ...ractor is required to be 650mm above the hotplates Measure the height of the ceiling and then the hotplate height from the floor The length of the wire supports should be calculated as follows Length of cable Ceiling height 350 650 Hotplate height Adjust the cables to the approximate required length X in Fig 15 These can be adjusted after install if required Ensure that the cable is looped back th...

Page 9: ...t the extractor is level Using 2 x 8mm spanners the extractor can be levelled using the adjustment system Fig 17 9 Mount the mains connection box S to the ceiling support plate using the 2 supplied screws D and proceed to connect the appliance to the mains supply as shown below Once complete secure the connection box lid with the 2 screws If you are in doubt as to how to connect the appliance to t...

Page 10: ...t trapped 12 Fit the 2 decorative curved panels M1 and M2 to the body of the extractor as shown note these can be installed offset as shown or at the same level as preferred Insert the screws X into the body leaving approximately 3mm protruding Hang the panels onto the body as shown finally tightening the screws to secure the chimney using a stubby screwdriver or spanner Fig 20 Fig 19 A A B C G Fi...

Page 11: ...ith the coloured markings identifying the terminals connecting to the fuse spur proceed as follows The wire which is coloured green and yellow must be connected to the terminal marked E Earth or coloured green The wire which is coloured blue must be connected to the terminal marked N Neutral or coloured black The wire which is coloured brown must be connected to the terminal marked L Live or colou...

Page 12: ...Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style To contact our Customer Care Department or for Service please contact us on the details below ...

Reviews: