Read and Save These Instructions

CARE OF FILTER

-

For greatest efficiency the permanent 

type aluminum foil filter should be removed and cleaned periodically.

To clean, the filter should be soaked in hot water and detergent, then 

thoroughly rinsed.

CARE OF EXTERIOR SURFACE

- Your Exhaust Unit is 

a beautifully finished addition to your kitchen. Clean with a mild deter-

gent to reserve its lasting beauty.

DO NOT

 use abrasive cleansers.

Distributor

Before  you  begin,  read  the  following  instruc-

tions completely and carefully. If followed, they 

will simplify the installation.

IMPORTANT:  OBSERVE ALL GOVERNING 

CODES AND ORDINANCES

SAVE THESE INSTRUCTIONS FOR THE 

LOCAL ELECTRICAL INSPECTOR'S USE

W

ARNING!!

       TO REDUCE THE RISK OF 

FIRE, ELECTRICAL  SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

 Use 

this unit only in the manner intended by the manufacturer. If you 

have  questions,  contact  the  manufacturer.  Before  installation 

and before servicing or cleaning unit, switch off power at ser-

vice panel and lock service panel to prevent power from being 

switched  on  accidentally.  When  the  service  disconnecting 

means cannot be locked, securely fasten a prominent device, 

such as a tag, to the service panel.

Installation work and electrical wiring must be done by quali-

fied person(s) in accordance with the National Electrical Code 

and  all  applicable  codes  and  standards,  including  fire  rated 

construction. When cutting or drilling into wall or ceiling, do not 

damage  electrical  wiring  and  other  hidden  utilities.  Use  only 

metal ductwork or ducted fans, routed to the outdoors.

Use with approved cord connection kit only.

ELECTRICAL  GROUNDING

  -  Permanently  ground  this 

unit in accordance with the latest National Electrical Code and 

applicable local codes and ordinances.

A  permanent ground connection should be made to the unit 

using a conductor of appropriate size from a grounded continu-

ous  metallic  cold  water  pipe,  a  grounded  lead  in  the  service 

panel,  or  a  properly  driven  and  electrically  grounded  ground 

rod. Do not ground to a gas supply pipe.

W

ARNING!! 

Sufficient air is needed for proper combus-

tion and exhausting of gases through the flue (chim-

ney) of fuel burning equipment to prevent back draft-

ing.  Follow  the  heating  equipment  manufacturer's  guidelines 

and safety standards such as those published by the National 

Fire Protection Association (NFPA), and the American Society 

for  Heating,  Refrigeration  and  Air  Conditioning  Engineers 

(ASHRAE), and the local code authorities.

C

AUTION!!

  For  general  ventilating  use  only.  Do  not 

use  to  exhaust  hazardous  or  explosive  materials  and 

vapors.

Form OME-004 02/06 628019A

©2006 Omega National Products, LLC.

Page 1

I

NTENDED FOR DOMESTIC COOKING ONLY

Division of Broan-NuTone LLC

Summary of Contents for 90026WHI1

Page 1: ...the service panel Installation work and electrical wiring must be done by quali fied person s in accordance with the National Electrical Code and all applicable codes and standards including fire rate...

Page 2: ...e junction cover 8 Seal holes around ventilating pipe and wir ing passing through ceilings or walls with caulking or insulation to prevent air loss 9 Install decorative range hood cover WARNING To red...

Page 3: ...t the fol lowing parts are needed 90354DUC1 Kit includes all parts required for this installation as shown below Optional Custom Wood Grille kit Unassembled Accommodates sizes to 6 x 10 90353OUF2 Oak...

Page 4: ...date EXCLUSIONS This warranty does not cover consumable parts such as charcoal filters and light bulbs This warranty does not apply if this product has been subjected to faulty installation misuse ab...

Page 5: ...se de l appareil et les travaux d lectricit doivent tre effectu s par des personnes qualifi es conform ment la r glementation en vigueur notamment les normes de la con struction ayant trait la protect...

Page 6: ...z jamais les l ments de surface allum s haute temp rature Les d bordements peu vent causer de la fum e et occasionner des coulements de graisse inflammables L huile doit tre chauff egraduellement bass...

Page 7: ...isation au trav ers de soffit les pi ces suivantes sont n cessaires 90354DUC1 Le kit inclut toutes les pi ces exig es pour cette installation comme mon tr ci dessous Page 7 Grille en M tal Collier R g...

Page 8: ...ommence la date d achat original Afin d tablir la date d achat original gardez l acte de vente dat le ch que d command ou toute autre vidence de la date originale d achat EXCLUSIONS Cette garantie ne...

Page 9: ...l Installation work and electrical wiring must be done by quali fied person s in accordance with the National Electrical Code and all applicable codes and standards including fire rated construction W...

Page 10: ...ctions according to the latest National Electrical Code and appli cable local ordinances 9 Replace junction cover 10 Seal holes around ventilating pipe and wir ing passing through ceilings or walls wi...

Page 11: ...onal parts required should be pur chased as needed To install this unit ductless through soffit the fol lowing parts are needed 90355DUC1 Kit includes all parts required for this installation as shown...

Page 12: ...nal purchase Rangaire will provide at no charge replacement parts for any parts of your kitchen ventilating equipment other than consumable parts which are defective in material or workmanship The rep...

Page 13: ...l et les travaux d lectricit doivent tre effectu s par des personnes qualifi es conform ment la r glementation en vigueur notamment les normes de la con struction ayant trait la protection contre les...

Page 14: ...bo te de jonc tion 10 Bouchez les trous autour du conduit de ven tilation et des c bles passant au travers de plafonds ou de murs avec du calfeutrage ou du mat riau isolant pour emp cher la perte d a...

Page 15: ...est inclus avec l unit 90039WHI1 Enraisond unegrandevari t d installations les pi ces additionnelles n cessaires devrant tre achet es selon besoin Pour installer cette unit sans canalisation au trav e...

Page 16: ...E OMEGA NATIONAL PRODUCTS LLC Pi ces Pendant une p riode d un 1 an apr s date d achat original Rangaire fournira aucuns frais des pi ces de rechange pour toutes les pi ces de votre quipement d a ratio...

Reviews: