Power On/Off
Power On/Off
the blower is turned On and Off. If lights are on and this button is pressed
the lights will also power off.
Lights Off/Dim/Bright
Lights Off/Dim/Bright
0 is off, I is dim, and II is bright.
Models AK6500, AK6536, AK6542, AK2500, AK2536 hoods are filter-less with a self cleaning feature.
The centrifugal blower system automatically liquifies cooking residue in its internal housing. Cooking
residues are often automatically liquified and can accumulate in the residue cups from everyday use.
Nevertheless, grease from cooking could also dry and adhere in the internal housing. Running the
self clean function periodically will flush out accumulated residue in the range hoods internal housing.
Cleaning should be performed approximately once a month under normal usage of 1 hour per day.
The hood may need to be cleaned more often depending on cooking habits.
Use a non-abrasive grease cutting detergent such as Simple Green or 409.
Remove safety grilles.
Turn the blower on the lowest speed setting.
With nozzle on “spray”, squirt the detergent directly
into the blower wheels 15 to 20 times for each wheel.
Allow blower to run on low speed for 5 to 10 minutes.
Turn blower off, re-install the safety grilles, remove
residue cups and clean cups with mild detergent or in
dishwasher.
WARNING
Use extreme caution while cleaning the hood when safety grilles are removed.
Beware of blowers catching onto hair, loose clothing and fingers. NEVER leave
children unattended.