E2/E4
Indicates water tank full or
possibly the incorrect wiring
of plug
User needs to pull out the rubber
stopper which is located at the bottom
of the unit, to drain the water away.
Check that the plug has been wired
correctly.
E3
Pipe temperature sensor
failed
Replace pipe temperature sensor (the
unit can also work without
replacement.)