3
Specifications
SEM-00011F 20101006
Specifications
PERFORMANCE
Discharge Volume
3.0 gal/m / 11.4 L/m
Pump Head Pressure
2000 psi / 138 bar
Temperature Rise
120˚F @ 2.0 gal/m / 49˚C @ 7.6 L/m
Temperature Limit (optional)
210˚F / 99˚C
Combustion Smoke/Bacharach
Scale
#1 OR #2 SMOKE
Carbon Monoxide Allowed
0.01%
Draft/Stack Installation
0.2” – 0.04” WC READING
Heat Input
172,200 Btu/Hr / 43,394 Kcal/Hr
GENERAL
Minimum Inlet Water Pressure
over 65 psi may require water inlet regulator
10 psi / 0.68 bar
Stack Size
8” OD / 203.2 mm OD
Weight
420 Lbs / 191 Kg
Fuel Tank Capacity
4.5 gal / 17 L
Pump to Coil Hose
p/n Y01-00016
Spray Tip
(#4.0 - 15˚) p/n JA0-15040-2
Discharge Hose Assembly
3/8” x 50’ 4000psi
P/N K02-03150E5
Belt
p/n R02-00229
Trigger Gun & Wand
p/n J06-00158-B
- Trigger Gun
p/n J06-00158
- Trigger Wand
p/n J06-00104EZ
Coil
Standard Coil & SS Wrapper
14”OD x ½”ID x 95’ Schedule 40
p/n W216RS-05207
Coil Back Pressure (New)
5 psi / 0.34 bar
Coil Back Pressure Requiring
Descaling
50 psi / 3.40 bar
Содержание Pressure Washers
Страница 1: ...Servic e Manua l Servic e Manua l g distribu c com 6 ...
Страница 20: ...20 Buner Breakdown Burner Breakdown ...
Страница 22: ...22 Burner Specs ...