3. ANNEX I. COMMUNICATION OBJECTS 

 

 

SECTION  

 
NUMBER  

 

SIZE  

IN/OUT  

 
FLAGS 

 

 

 
 

RANGE 

 

 

NAME  

 

DESCRIPTION  

VALUES  

 
   1st TIME 

 
 

RESET

 

 

0  

3 bytes  

I/O  

WT  

RANGE  

1ª V

0:00 

EZ  

Last

 

Time  

Current time  

 

1  

3 bytes  

I/O  

WT  

 

01/01/2000 

Last 

Date  

Current date  

 

2  

1byte  

O  

T  

 

Indifferent 

Indifferent 

Scenes  

One only object used by device  

           GENERAL

 

3  

2bytes  

O  

RT  

0ºC    
60ºC

 

Indifferent 

Indifferent  

Temperature  

Internal sensor value  

 

4  

1bit  

 

 

 

Display lighting  

1=Light the Display; 0=No 
action  

 

1bit 

 

Indifferent 

Indifferent 

Touch blocking 

1=Touch Disabled; 0=Touch 
free 

 

6 - 17 

1bit  

O  

T  

 

Indifferent  

Indifferent  

[Home x Box x] Binary control  

1-bit generic control  

 

 

1bit 

O  

T  

 

Indifferent  

Indifferent  

[Home x Box x]  Light on/off  

0=Off; 1=On  

 

 

1bit 

O  

T  

 

Indifferent  

Indifferent  

[Home x Box x] Move shutter  

0=Up; 1=Down  

 

 

1bit 

O  

T  

 

Indifferent  

Indifferent  

[Home x Box x] Security control  

0=Deactivate; 1=Activate  

 

 

1bit 

 

Indifferent 

Indifferent 

[Home x Box x] Simulation Channel 

0=Off; 1=On 

 

 

1bit 

 

Indifferent 

Indifferent

 

[Home x Box x] Fan control 

 

0=Down; 1=Up

 

 

 

 

1bit 

 

Indifferent 

Indifferent 

[Home x Box x] Mode control 

 

0=Cool; 1=Heat 

 

 

 

1bit 

 

Indifferent 

Indifferent 

[Home x Box x] Swing control 

 

1=Swing; 0=Stop/Step 

 

 

18 – 29  

1bit  

I  

WU  

 

0  

Last  

[Home x Box x] Binary Indicator  

1-bit generic indicator  

 

 

1bit 

I  

WU  

 

0  

Last  

[Home x Box x] Light Indicator  

0=Off; 1=On  

HOME AND HOME 2  

 

1bit 

I  

WU  

 

0  

Last  

[Home x Box x] Security Indicator  

0=Disarmed; 1=Armed  

 

1bit 

WU 

 

 

 

[Home x Box x] Mode control 

0=Cool; 1=Heat 
 

 

1bit 

WU 

 

 

 

[Home x Box x] Swing indicator 

 

1=Swing; 0=Stop/Step 
 

30-41 

1 bit 

 

Indifferent 

Indifferent 

[Home x Box x] Stop shutter 

0 or 1 -> Stop 

 

1 bit 

 

Indifferent 

Indifferent 

[Home x Box x] Presence simulation 

0=Disabled; 1=Enabled 

42-53 

4bits  

O  

T  

 

Indifferent  

Indifferent  

[Home x Box x]  Light dimming  

4-bits dimmer control  

 

54-65 

1byte  

O  

T  

 

Indifferent  

Indifferent  

[Home x Box x]  Precise Light dimming  

1-byte dimmer control  

 

 

 

 

Indifferent 

Indifferent 

[Home x Box x] 1 byte control 
 

1 byte generic control 
 

 

 

 

 

Indifferent 

Indifferent 

[Home x Box x] Mode control 
 

0=Aut;1=Heat;3=Cool;9=Fan; 
14=Dry 

 

66-77 

1byte  

I  

WU  

 

0  

Last  

[Home x Box x] Light Indicator  

0%=Off; 100%=On  

 

 

 

I  

WU  

 

0  

Last  

[Home x Box x] Shutter position  

0%=Top; 100%=Bottom  

 

 

 

I  

WU 

 

0  

Last 

[Home x Box x] Mode indicator 

0=Auto; 1=Heat; 
14=Dry;9=Fan;3=Cool 

 

 

 

WU 

 

 

 

[Home x Box x] Fan Indicator 

0%: Auto; 1-33%: Minimum; 34-
66%: Medium; >67%: 
Maximum 

 

 

 

WU 

 

 

 

[Home x Box x] Fan Indicator 

0=Auto; 1=Minimum; 
2=Medium; 3=Maximum 

 

 

 

WU 

 

 

 

[Home x Box x] 1 byte Indicator 

1 byte generic indicator  

 

78-89  

2bytes  

O  

T  

-20ºC to 

95ºC 

Indifferent  

Indifferent  

[Home x Box x] Temperature control  

from -20ºC to 95ºC 

 

 

90-101  

2bytes  

I  

WU  

-20ºC to 

95ºC 

25ºC  

Last  

[Home x Box x] Floating point Indicator 

From -273ºC to 670760ºC 
From 0 to 670760 m/s 
From 0% to 670760% 
From 0 lux to 670760 lux 
From -670760 to 670760 
 

 

 

WU 

 

 

 

[Home x Box x] Temperature indicator 

from -20ºC to 95ºC 

 

 
 

 
 

 
 

 
 

 
 

 
 

 

 
 
 

 
 

 

 
 

 
 

 

Содержание InZennio Z38i

Страница 1: ...INZENNIO Z38i KNX Touch Panel ZN1VI TP38i Edition 2 1 Version 2 1 PRODUCT MANUAL...

Страница 2: ...CALIBRATION 12 2 2 7 TEMPERATURE SENDING PERIOD 13 2 2 8 PASSWORD 13 2 3 PAGES 14 2 3 1 HOME AND HOME 2 PAGES 15 2 3 1 1 BINARY CONTROL 16 2 3 1 2 LIGHT CONTROL 17 2 3 1 3 SHUTTER CONTROL 19 2 3 1 4 C...

Страница 3: ...4 1 2 LONG PRESS 46 2 4 1 3 THRESHOLD TIME 46 2 4 1 4 RESPONSE DELAY 47 2 4 1 5 BLOCK 47 2 4 2 SWITCH SENSOR 47 2 4 2 1 RISING EDGE 48 2 4 2 2 FALLING EDGE 48 2 4 2 3 SENDING OF 0 DELAY 48 2 4 2 4 SEN...

Страница 4: ...Control 5 Functions Schedule Programming 4 Functions Climate Control 6 Functions Technical Alarms 6 Functions Display Parameters IR Receiver built in Remote Control 4 Binary Inputs for Voltage free p...

Страница 5: ...be enabled and its hierarchy Figura 1 1 Schematic page organization HOME PAGE MENU PAGE Specific pages access HOME 2 PAGE SCENES 1 SCH PROGRAMMING CLIMA SCENES 2 SCH PROGRAMMING CLIMA SCENES 3 SCH PR...

Страница 6: ...age this will be the starting point once the necessary boxes have been enabled to access the most commonly required functions The Home 2 page is just like the Home one as far as functionality and pote...

Страница 7: ...ead the device Datasheet included in the original package of the device and also available at http www zennio com 2 ETS CONFIGURATION To begin with the panel configuration it is necessary to import in...

Страница 8: ...ameterized They will be explained in the following sections General to configure the general options of the panel and IR control Pages to enable and customize each of the functioning windows Home 1 Ho...

Страница 9: ...wn Luminosity attenuation level Completely Dark After 45 seconds Auto Dimming the own auxiliary light on the display will remain OFF until a new touch on it is made Low Luminosity After 45 seconds Aut...

Страница 10: ...ices in the installation for their corresponding values in order to update the display indicators If this option is enabled Yes the Delay field appears where to parameterize the time in seconds the pa...

Страница 11: ...off down Right on up With this configuration the pair button on the left of the box will send the order to switch off move down last and lower whereas the right button will send the orders to switch...

Страница 12: ...d associate this IR controller zone to any of the Home or Home 2 pages Note I Buttons arrangement on the remote controller is similar to the Home Home 2 boxes structure to make its control easier Note...

Страница 13: ...ault password is 1234 In the field Allow password changing one can choose whether the password can be modified in the panel itself or not If this change is not allowed the password can only be changed...

Страница 14: ...d changing from the panel 2 3 PAGES This parameterization section details the enabling and configuration of the different pages of the InZennio Z38i including the submenus they offer Figure 2 4 Pages...

Страница 15: ...so that a user can easily access the most common used functions when controlling an installation As well as the pages every box on Home and Home 2 pages has a parametrizable field Name This field all...

Страница 16: ...ROL This is a generic control to communicate all those devices susceptible to be by sending a single bit 0 or 1 The following options will appear Button 1 Always enabled by default Short press By pres...

Страница 17: ...nsmit data independently both of them also share the same Communication Object The way to parrameterize this button is exactly the same as for Button 1 Indicator By activating this parameter a status...

Страница 18: ...l reduce or increase the brightness on the controlled lamps Dimming step Seven different regulation levels are available for this duty A long press on the display buttons will reduce or increase the b...

Страница 19: ...press on any of the two buttons will increase or reduce gradually 10 the brightness level Indicator This will inform users about the brightness percentage applied at any time Icon An icon can be assoc...

Страница 20: ...n be associated to the page box Indicator By activating this parameter users can insert an indicator between both buttons to get estimation in percentage terms of the shutter position 2 3 1 4 CLIMATE...

Страница 21: ...pe corresponding the selected option This characteristic also allows controlling external climate systems 2 3 1 5 1 BYTE CONTROL This is a generic control to communicate all those devices susceptible...

Страница 22: ...imum Value and Maximum Value Short press Rise or lower one single point in the range with every short key press Long press Rise or lower 10 points in the range with every long key press Icon A pair of...

Страница 23: ...e to know how Example Guess it is defined the Scene Night programming the Panel with parameters and group addresses via ETS Turn all the lights Off Turn Off the Heating and the A C Systems Activate th...

Страница 24: ...whether to carry out an absolute temperature control positive values or a temperature control through a temperature offset positive and negative values to be added to the current temperature when rec...

Страница 25: ...IS RECEIVED This box should be enabled when users need to know when a 0 has been received through the specific Communication Object ACTION WHEN VALUE 1 IS RECEIVED This box should be enabled when use...

Страница 26: ...f the value represented In this particular case enabling a box as Floating Point indicator integrators can select the type of data represented on the display choosing among Temperature C Range 273 C 6...

Страница 27: ...to the bus unless the correct password is entered Icon A pair of icons can be associated to the page box Indicator By activating this parameter a status indicator will be inserted between both button...

Страница 28: ...r the ON OFF within the parameterized limits Note This simulation can be enabled disabled through the display or through an object and once activated this will only be running during the parameterized...

Страница 29: ...xes available Climate 6 boxes available To enable these pages just go to the Main Menu PAGES when Editing Parameters 2 3 2 1 SCENES This specific page has 5 configurable boxes as shown below Figure 2...

Страница 30: ...he Timers are associated to the On Off of the devices in the KNX installation and any specific page enabled to scenes control will have available four boxes each enabled page to this purpose Figure 2...

Страница 31: ...ute when the ON programming set by the user is fulfilled Only for Timer OFF The Scene Number Off box will appear where it is needed to write the scene number to execute when the OFF programming set by...

Страница 32: ...nd the timers page 3 this way Box 3 linked to scene number 11 Only for ON In case that all these timers send their own scene at the same time the only scene that will be sent is the one linked to the...

Страница 33: ...s done from Specific Pages 1 2 3 and 4 after being enabled to this purpose It is possible to control the two internal thermostats of the panel through these specific Climate pages For this aim it is n...

Страница 34: ...ing on off of the system are enabled On Off Sending and On Off Reception Moreover a new 1 bit object appears Activity indicator to be associated through a same group address to the 1 bit control varia...

Страница 35: ...tively the setpoint temperature to be set and the current setpoint of the climate system Short or long pressings over the box are allowed to set the desired setpoint the temperature will change in 0 5...

Страница 36: ...ry Fan Cool Note This second option can only be selected to control Air Conditioning Systems Depending on the selected option one of these pairs of communication objects will be enabled 1 bit objects...

Страница 37: ...tage is received from the system with the following ranges 0 Auto 1 33 Min 34 66 Med 67 100 Max Integer indicator Two new communication objects are available Clima x Fan Sending 1 bit object to the to...

Страница 38: ...eption which could be linked to the 1 bit objects in charge of the control of functions of the climate system that allows a binary control for example for controlling the Comfort prolongation of the t...

Страница 39: ...devices will be cyclically monitored by enabling this parameter This parameter assures two features the detection of incidents in the minor time possible and the security that the device of detection...

Страница 40: ...gain to the bus its normal status If cyclical monitoring is enabled it will be the own device which sends this status when danger disappears 2 3 4 CONFIGURATION This is a specific page where the user...

Страница 41: ...ower failure this will show the time it had just before the incident Note I When a Power bus failure occurs please have on mind the delay this implies to correct it Note II There are different KNX dev...

Страница 42: ...o events Note I It is necessary to press continuously the button for a few seconds to apply the Reset correctly Note II Take into account that after the reset a few seconds delay could take place resp...

Страница 43: ...n Open Contact 2 4 1 PUSH BUTTON A push button connected to an input consists of a device which allows or not the current flow while this is being pushed in normal conditions push buttons contacts are...

Страница 44: ...two consecutive sends in the Cyclical Sending SHUTTER CONTROL This function results on sending 1 bit to the bus in order to control the shutters RESPONSE The corresponding Control Object may be used t...

Страница 45: ...I If the option up down switched is chosen to short press stop shutter action will not be able to be done in any point of the trajectory with other short key press over the same input DIMMER CONTROL T...

Страница 46: ...d Once selected the DIMMER CONTROL option it is necessary to set this parameter See figure 2 6 to know the available dimming steps SENDING OF A SCENE This function results on sending a 1 byte Scene Co...

Страница 47: ...he input turns into the enabled state again without taking into consideration the actions carried out while being disabled 2 4 2 SWITCH SENSOR A Switch Sensor connected to an input consists of an elec...

Страница 48: ...value 0 through the Switch Sensor Edge communication object when this value has been detected on an incoming edge 2 4 2 4 SENDING OF 1 DELAY Time to wait before sending value 1 through the Switch Sen...

Страница 49: ...tantly to the bus If not cyclically sending is needed please select value 0 in this field 2 4 2 7 BLOCK This parameter uses the object Block This object will disable the input When receiving a 1 throu...

Страница 50: ...es by properly linking the objects associated to the specific Climate page with the specific objects of the thermostat to be monitored and controlled Figure 2 14 Thermostat 1 Configuration To obtain t...

Страница 51: ...ght Indicator 0 Off 1 On HOME AND HOME 2 1bit I WU 0 Last Home x Box x Security Indicator 0 Disarmed 1 Armed 1bit I WU Home x Box x Mode control 0 Cool 1 Heat 1bit I WU Home x Box x Swing indicator 1...

Страница 52: ...de sending 1 Comfort 2 Standby 3 Economy 4 Protection 150 153 1 byte I WTU Clima x Special Mode reception Value returned by the machine 154 157 1 bit I T Clima x Setpoint offset sending 0 Decrease 1 I...

Страница 53: ...pecial Mode x x Comfort Standby Economy or Protection 0 Off 1 On 200 201 1 bit I W 0 1 0 Last Tx Window status input 0 Closed 1 Opened 202 203 1 bit I W 0 1 0 0 Tx Comfort prolongation 0 Nothing 1 Tim...

Страница 54: ...ZENNiO AVANCE Y TECNOLOG A www zennio com 54 ZENNIO TECHNICAL DOCUMENTATION BECOME USER http zennioenglish zendesk com TECHNICAL SUPPORT...

Отзывы: