MID - Declaration of Conformity

zelsius® C5-ISF is produced and 

tested in compliance with the Euro-

pean Measuring Instruments Direc-

tive 2014/32/EU (MID). According to 

this directive, devices are no longer 

carrying an initial verification stamp, 

but rather the year of the device’s 

declaration of conformity (recogniz

-

able on the front of the device, for ex-

ample: M19=2019). The MID controls 

the use of measuring device up to the 

moment they are placed on the mar-

ket resp. their first putting into use. 

After this, the national regulations 

for devices subject to compulsory 

verification apply within the EU. The 

duration of initial verification validity 

in Germany remains 5 years for heat 

meters. After this period has expired, 

the measuring device may no longer 

be used for billing in commercial use. 

The regulations resp. validity period 

may vary in other countries of the EU. 

If you have questions, please direct 

them to 

[email protected]

The declaration of conformity is 

attached to each measuring instru-

ment. The latest information about 

this product can be downloaded 

from 

 www.zenner.com 

Safety instructions

Electro-magnetic interference

zelsius® C5-ISF fulfils the national 

and international requirements for 

interference resistance. To avoid 

malfunctions due to other interfer-

ences, do not install fluorescent 

lamps, switch cabinets or electric 

devices such as motors or pumps in 

the immediate vicinity of the meter. 

Cables leaving the meter should not 

be laid parallel to live cables (230 V) 

(minimum distance 0.2 m).

Care instructions

Clean plastic surfaces with a damp 

cloth only. Do not use any scouring 

or aggressive cleaning agents! The 

device is maintenance-free during 

the service life. Repairs may only be 

carried out by the manufacturer or 

authorized service partners.

Installation manual

Safety instructions for installation

Read these instructions carefully right 

up to the end before starting to mount 

the device! The installation has to be 

done by qualified professional per

-

sonnel. The current laws and regula-

tions have to be observed, especially 

the PTB technical guidelines K8 und 

K9, EN1434 part 1+6, (in Germany also 

AGFW directive FW202, FW510 and 

FW218). At devices with M-Bus the 

general rules of technology and the 

respective regulations for electrical 

installations have to be followed. 

Caution with discharge of hot water 

during the installation – scalding 

danger!

 Do not carry the meter by the 

cables.

The maximum heating water tem-

perature at the flow sensor may not 

exceed 90 °C. For heating systems 

with a lack of temperature mixing 

resp. with temperature stratification 

a straight pipeline of min. 10 x DN has 

to be provided upstream of the meter. 

No straight lengths of pipe required. 

It is important to ensure adequate sys

-

tem pressure to avoid cavitation.

With combined heat and cooling 

measuring or only cooling measuring 

the calculator has to be mounted on 

the wall for protection of external con-

densation (for Germany and Austria: 

in the case of cooling and combined 

heat / cooling meters, the cooling 

registers are not  calibrated and may 

not be used for billing purposes in 

commercial transactions. For this 

purpose, devices with a separate type-

examination certificate are currently 

required).

All manuals and user guides at all-guides.com

Содержание zelsius C5-ISF

Страница 1: ...and 3 inputs outputs qp 0 6 1 5 2 5 m h GB PDF Download Notice d installation Istruzioni per il montaggio Notice d installation et d utilisation 26 Compteur lectronique d nergie thermique et de frigor...

Страница 2: ...DFS 5 Einbau des Kugelhahns 5 Montage W rme K ltez hler 5 Montage Temperaturf hler 5 Einbau in Bestandstauchh lsen 6 Inbetriebnahme 6 Impulsein und ausg nge optional 7 M Bus optional 8 Programmierung...

Страница 3: ...idung von Kavitation bar 0 3 Nenndruck Spitzendruck PS PN 16 16 IP Schutzklasse 54 65 f r K ltez hlung und kombinier te W rme K ltez hlung Einbaulage horizontal horizontal um 90 gekippt vertikal Fall...

Страница 4: ...ind 0 2 m Pflegehinweise Kunststoffoberfl chen nur mit feuch tem Tuch reinigen Keine scheuern den oder aggressiven Reinigungsmit tel einsetzen Das Ger t ist ber die Einsatzdauer wartungsfrei Repa ratu...

Страница 5: ...igung kontrollieren Neuen Durchflusssensor flie rich tungs und lagerichtig einbauen Rechenwerk des W rmez hlers in die gew nschte Ableseposition drehen Montage Temperaturf hler Die Montage der Tempera...

Страница 6: ...nformer Temperaturf hler f r W rmez hler in Bestandstauchh lsen ver ffent licht in den PTB Mitteilungen 119 2009 Heft 4 eingesetzt werden Die Regelung hat nach aktuellem Stand den Geltungszeitraum bis...

Страница 7: ...erts Typische Beschaltung Der Anschlu eines externen Widerstandes kann notwendig sein um die Strombegrenzung zu gew hrleisten Inbetriebnahmeprotokoll gem PTB Richtlinie TR K9 ausf llen Hinweis Nur f r...

Страница 8: ...die ber eine integrierte Funkschnittstelle mit Antenne verf gen sind zur besseren Erkennbarkeit auf der Oberschale je nach Ausf hrung mit folgenden Symbolen gekennzeichnet wM Bus Beispiel Ausgang 1 E...

Страница 9: ...hfluss im Sendeintervall Daten wireless M Bus LoRaWAN Frequenzband 868 MHz 868 MHz Funkprotokoll wireless M Bus EN 13757 4 und gem Open Metering Standard OMS unterschiedliche Protokoll inhalte m glich...

Страница 10: ...ie vom letzten Stichtag bis heute Aktueller Monatsverbrauch W rmeenergie Aktueller Monatsverbrauch K lteenergie Aktuelles Monatsvolumen Maximaler Durchfluss Maximaler Monats Durchfluss Maximale Leistu...

Страница 11: ...sverh ltnisse durchlaufen E 20 E 25 E 30 E 35 E 40 E 45 E 50 P 20 P 25 P 30 P 35 P 40 P 45 P 50 E 0 E Ethylenglykol P Propylenglykol E 0 Wasser ohne Glykol Zusatz Bei Erreichen des gew nschten Wertes...

Страница 12: ...ung R cklauff hler Temperaturf hler pr fen 5 Kurzschluss Vorlauff hler Temperaturf hler pr fen 6 Unterbrechung Vorlauff hler Temperaturf hler pr fen 7 Batteriespannung Ger t austauschen 8 Hardwarefehl...

Страница 13: ...er mitnehmen und fachgerecht entsorgen Sofern dies bez glich keine andere vertragliche Regelung getroffen wurde k nnen alternativ die Altger te und Zubeh r auch bei unserer Betriebsst tte in D 09619 M...

Страница 14: ...the ball valve 17 Mounting heat cooling energy meter 17 Installation of the temperature sensors 17 Installation with existing immersion sleeves 18 Commissioning 18 Pulse inputs and outputs optional 19...

Страница 15: ...0 3 Nominal pressure peak pressure PS PN 16 16 IP protection class 54 65 for heating and cooling energy metering Installation position horizontal horizontal tipped through 90 vertical Heat carrier med...

Страница 16: ...ons Clean plastic surfaces with a damp cloth only Do not use any scouring or aggressive cleaning agents The device is maintenance free during the service life Repairs may only be carried out by the ma...

Страница 17: ...g position Installation of the temperature sensors The installation of the tempera ture sensors should be prefer ably symmetrical and as direct installation Do not remove the temperatur sensor if alre...

Страница 18: ...Installation with existing immersion sleeves In Germany the C5 can be put into use in connection with existing im mersion sleeves in accordance with the article Putting into use of MID homologated tem...

Страница 19: ...en sure an integrated current limiter Example Output 1 energy output Energy display XXXXX XXX Last position 0 001 MWh 1 kWh Output pulse 1 kWh U 3 30 V Imax 20 mA GND Pulse V Out white yellow green b...

Страница 20: ...Radio optional General information zelsius energy meters which have an integrated radio interface with an antenna are marked for better visibil ity on the upper cover with one of the following symbol...

Страница 21: ...l Data wireless M Bus LoRaWAN Frequency 868 MHz 868 MHz Radio protocol Wireless M Bus EN 13757 4 and according to the Open Metering Standard OMS different radio telegram contents are possible accordin...

Страница 22: ...g energy difference from last due date to now Heat energy difference from 1 of this month to now Cooling energy difference from 1 of this month to now Volume difference from 1 of this month to now Max...

Страница 23: ...hes With each short press on the button the following loop for different mixing ratios runs E 20 E 25 E 30 E 35 E 40 E 45 E 50 P 20 P 25 P 30 P 35 P 40 P 45 P 50 E 0 E ethylene glycol P propylene glyc...

Страница 24: ...uit supply sensor Check sensors 6 Interruption supply sensor Check sensors 7 Battery voltage Exchange device 8 Hardware error Exchange device 9 Hardware error Exchange device 10 Error in the measuring...

Страница 25: ...waste disposal via ZENNER is possible Your local or municipal authority or the local waste disposal company can give you information relating the collec tion points for your used equipment ZENNER will...

Страница 26: ...compteur d nergie thermique frigorifique 29 Connection des sondes de temp rature 29 Indications relatives au montage des doigts de gants existants 30 Mise en service 30 Entr es et sorties pour impulsi...

Страница 27: ...imale pour viter la cavitation bar 0 3 Pression nominale Pression maximale PS PN 16 16 Indice de protection 54 65 pour la mesure combin e de frigorie et d nergie thermique de frigorie Position d insta...

Страница 28: ...u r seau lectrique 230 V distance minimale 0 2 m Conseils d entretien Nettoyez les surfaces plastiques uniquement avec un chiffon humide N utilisez pas de d tergents abrasifs ou agressifs L appareil e...

Страница 29: ...eur de volume adaptateur Employez uniquement des mat riaux d tanch it neufs et sans d faut pas de chanvre ou simi laire Nettoyez les surfaces d tan ch it et assurez vous qu elles ne soient pas endomma...

Страница 30: ...vec type de sonde de temp rature TS 45 5 voir plaque signal tique sur le c ble les deux sondes doivent toujours tre mont es dans l agent caloporteur Le montage dans un doigt de gant n est pas autoris...

Страница 31: ...nt d une r sistance externe peut s av rer n cessaire pour garantir la limitation du courant U 3 30 V Imax 20 mA GND Pulse V Out blanc jaune vert marron impulsion Attendez pour la mise jour de l affich...

Страница 32: ...it s Les compteurs d nergie zelsius qui disposent d une interface radio int gr e avec l antenne sont marqu sur le capot sup rieur par le symbole suivant pour une meilleure visibilit wM Bus Exemple Sor...

Страница 33: ...nsmission Sp cifications wireless M Bus LoRaWAN Fr quence 868 MHz 868 MHz Protocole radio wireless M Bus EN 13757 4 et conforme Open Metering Stan dard OMS diff rents protocolles de donn es possibles...

Страница 34: ...re Energie la date rep re Energie frigorifique la date rep re Volume D bit Temp rature aller Temp rature retour Diff rence de temp rature Puissance instantan e Energie thermique Diff rence date date d...

Страница 35: ...ective les diff rentes proportions de m langes sont parcourues en boucle E 20 E 25 E 30 E 35 E 40 E 45 E 50 P 20 P 25 P 30 P 35 P 40 P 45 P 50 E 0 E Ethyl neglycol P Propyl neglycol E 0 Eau sans addit...

Страница 36: ...it sonde aller V rifier sondes de temp rature 6 Interruption sonde retour V rifier sondes de temp rature 7 Tension pile Remplacer l appareil 8 Erreur du mat riel Remplacer l appareil 9 Erreur du mat r...

Страница 37: ...votre appareil usag Les points de reprise de vos appareils usag s sont disponibles par exemple la mairie locale aupr s des d chetteries locales Zenner assure dans tous les cas une limination professi...

Страница 38: ...la a sfera 41 Installazione del contatore di calore raffrescamento 41 Installazione delle sonde di temperatura 41 Installazione con manicotti ad immersione esistenti 42 Messa in funzione 42 Ingressi u...

Страница 39: ...Pressione nominale pressione di picco PS PN 16 16 Classe di protezione IP 54 65 per la misurazione dell energia di riscaldamento e raffrescamento Posizione di installazione orizzontale orizzontale inc...

Страница 40: ...one durante gli anni di validit della taratura Le riparazioni possono essere eseguite solo dal produttore o da partner di assistenza autorizzati Manuale di installazione Indicazioni di sicurezza relat...

Страница 41: ...are la volumetrica nuova in base alla direzione di flusso e alla posizione Girare la parte elettronica del con tatore nella posizione di lettura desiderata Installazione delle sonde di tempe ratura L...

Страница 42: ...re installate direttamente nel fluido NON consentita l installa zione in pozzetti Installazione con manicotti ad im mersione esistenti Secondo l articolo Installazione della sonda MID per contatori di...

Страница 43: ...ne di corrente U 3 30 V Imax 20 mA GND Pulse V Out bianco giallo verde mar rone impulso Attendere l aggiornamento della temperatura sul display Al termine della messa in funzione apporre i sigilli con...

Страница 44: ...accia radio integrata con un antenna sono con trassegnati per una migliore visibilit sul coperchio superiore con uno dei seguenti simboli wM Bus Esempio Uscita 1 uscita energia elettrica Indicatore d...

Страница 45: ...tenza nell intervallo di trasmissione Dati wireless M Bus LoRaWAN Frequenza 868 MHz 868 MHz Protocollo radio wireless M Bus EN 13757 4 secondo Open Metering Stan dard OMS Possibili diversi protocolli...

Страница 46: ...di raffrescamento dall ultimo giorno fisso d azzeramento fino ad oggi Calore differenza dal 1 di questo mese ad oggi Raffrescamento differenza dal 1 di questo mese ad oggi Volume differenza dal 1 di q...

Страница 47: ...r il seguente elenco di numeri per diverse concentrazioni di miscele glicolate E 20 E 25 E 30 E 35 E 40 E 45 E 50 P 20 P 25 P 30 P 35 P 40 P 45 P 50 E 0 E glicole etilenico P glicole propilenico E 0 a...

Страница 48: ...torno Controllo delle sonde di temperatura 5 5 Controllo delle sonde di temperatura 6 Interruzione sonda della mandata Controllo delle sonde di temperatura 7 Voltaggio difforme della batteria Sostitui...

Страница 49: ...ata utile e che li smaltiscano in maniera corretta Per ulteriori informazioni potete contattare la ns sede al seguente numero telefonico 051 198 733 80 ZENNER assicurer sempre di informarvi sul corret...

Страница 50: ...Notice All manuals and user guides at all guides com...

Страница 51: ...All manuals and user guides at all guides com...

Страница 52: ...er bernehmen wir keine Haftung ZRI_SAP155769_191028 ZENNER International GmbH Co KG R merstadt 6 66121 Saarbr cken Germany Telefon 49 681 99 676 30 Telefax 49 681 99 676 3100 E Mail info zenner com In...

Отзывы: