MID - Initial verification

zelsius

®

 C5-CMF is produced and tested in 

compliance with the new European measuring 
instruments  directive  (MID).    According  to  this 
directive, devices are no longer carrying an initial 
verification stamp, but rather the year of the de-
vice’s declaration of conformity (recognizable on 
the front of the device, for example: M12). The 
MID controls the use of heat meters up to the 
moment they are placed on the market resp. their 

first putting into use. After this, the national regu-
lations for devices subject to compulsory verifica-
tion apply within the EU.
The duration of initial verification validity in Ger-
many remains 5 years for heat meters. After this 
period has expired the measuring device may 
no longer be used for billing in commercial use. 
The regulations resp. validity period may vary in 
other countries of the EU. ZENNER International 
GmbH & Co. KG declares that this product with 

Technical data calculator

Temperature range

°C

0…105

Temperature difference range

K

3…80

Display

  LCD 8-digit + additional character

Ambient temperature

°C

 5...55

Minimum temperature diffence

K

3

Resolution temperature

°C

0,01

Measurement frequency

s

adjustable ex works beginning with  2s, standard 30s

Unit to read the heat consumption

Standard MWh; optionally kWh, GJ

Data storage

1 x daily

Due date values 

Storage of all monthly values during the entire operating time

Maximum value storage

extensive storage of flow rate, performance and other parameters

Interface

Standard

optical interface (ZVEI, IrDA)

optional

M-Bus, wM-Bus, RS485, radio

Supply

3,6 V lithium battery (different capacities)

Battery lifetime

years

> 6, opt. > 11 (changeable during the operating time)

Protection class

IP54

EMC

C

Ambient conditions / 

climatic influencing

(valid for complete compact meter)

- climatic

Highest permissible ambient temperature 55°C

Lowest permissible ambient temperature  5°C

Humidity class IP54

- mechanical

  class  

M1

- electromagnetic 

  class

E1

Содержание zelsius C5-CMF

Страница 1: ...sius C5 CMF Installation and operating manual electronic compact heat meter with coaxial measuring capsule CMF M Bus wM Bus and 3 inputs outputs optional qp 0 6 1 5 2 5 m3 h EnergyMetering All that counts ...

Страница 2: ...0 100 Starting flow horizontally ca l h 5 5 7 Pressure loss at qp bar 0 25 bar Temperature range C 10 C θq 90 C Minimum pressure avoiding of cavitation bar 0 3 Measurement accuracy class 3 Connecting interface M60 IST TE1 Nominal pressure PS PN 16 Nominal diameter DN depending on the connecting interface Installation position horizontally or vertically no upside down installation Installation retu...

Страница 3: ...onal GmbH Co KG declares that this product with Technical data calculator Temperature range C 0 105 Temperature difference range K 3 80 Display LCD 8 digit additional character Ambient temperature C 5 55 Minimum temperature diffence K 3 Resolution temperature C 0 01 Measurement frequency s adjustable ex works beginning with 2s standard 30s Unit to read the heat consumption Standard MWh optionally ...

Страница 4: ...mp cloth only Do not use any scouring or aggressive cleaning agents The device is maintenance free during the service life Repairs can only be made by the manufacturer The most up to date information about this prod uct and of our installation notice can be found at www zenner com Pulse inputs and outputs optional By meters with pulse inputs the pulse value can be called up in the display see the ...

Страница 5: ...rm 1434 3 and operates with 2400 baud fixed The two conductors can be connected in any order to the M Bus network colour connection signification brown M Bus 1 M Bus Line 1 white M Bus 2 M Bus Line 2 Dimensions Height compact version H 50 mm Height combiversion H1 H2 H 65 mm Measure X is depending from the used concentric flow meter IST M60 TE1 Connecting sizes Nominal flow qp m h 0 6 1 5 2 5 Nomi...

Страница 6: ...pstream of the meter It is important to ensure adequate system pres sure to avoid cavitation To mount the heat computer of the C5 CMF in combi version on the wall the supplied mounting adapter has to be used The review of the ap proval can be identified definitely in the display menu Level 3 ZENNER recommends to use direct temperature measurement and not to use immersion sleeves The measuring caps...

Страница 7: ...e fitted into the groove Use only new and flawless sealing material Use only new and flawless sealing material Remove the protective cap 1 from the new measuring capsule 5 and then screw into the EAS 4 Tighten measuring capsule up to the metallic stop with a hook wrench for example accord ing to DIN 1810 A 68 75 mm Turn heat calculator to desired reading position Information The best measuring res...

Страница 8: ...display advances and the tem peratures displayed correspond with the actual temperatures see the display overview Wait for the temperature display to be updated 1 2 sec Secure the measuring capsule and the EAS with the enclosed sealing material against un authorised removal Fill in the putting into use report in accordance with PTB Directive TR K9 Load Asymmetric sensor installation for zelsius wi...

Страница 9: ...eck sensors 2 Temperature out of measuring range Check sensors 3 Short circuit return sensor Check sensors 4 Interruption return sensor Check sensors 5 Short circuit supply sensor Check sensors 6 Interruption supply sensor Check sensors 7 Battery voltage Exchange device 8 Hardware error Exchange device 9 Hardware error Exchange device 100 Hardware error Exchange device 800 Wireless interface Excha...

Страница 10: ...difference from last due date to now Cooling energy difference from last due date to now Heat energy difference from 1 this month to now Cooling energy Segment test End of the battery Error status System Date Maximal Flow Cooling energy difference from 1 this month to now Volume difference from 1 this month to now Due date cooling energy Energy Last due date Date last due date Volume Supply temper...

Страница 11: ...r status System Date m System Time Operation hours Primary M Bus address lue Certification model Firmware version wer sioning Function Output 3 Function Output 2 Function Output 1 Opto readout energy Pulse value Input 1 Pulse value Input 2 Pulse value Input 3 Level 4 Legend Press the button briefly S to switch through the display from top to bottom When you have reached the last menu item the devi...

Страница 12: ... or other accessories are disposed Therefore please contact the department of your local authority which is responsible for waste disposal Alternatively a waste disposal via ZENNER is possible Your local or municipal authority or the local waste disposal company can give you informa tion relating the collection points for your used equipments Attention Do not dispose of the devices with domestic w...

Отзывы: