9
Additional settable parameters:
■
Reset logger values
■
Reset status bits (manipulation, errors)
4. Wall mounting
Install wall bracket with the enclosed wall plugs and
screws as shown below on a flat wall surface. Slide
PDC over the wall bracket to the PDC clicks.
Dismounting of the PDC from the wall bracket: Use
screwdriver or similar tool to push the upper strap
of the wall bracket backwards and then pull the
PDC downwards.
Dimensions (LxWxH):
127mm x 40,6mm x 42mm
Data telegram contents (wM-Bus)
The EDC module can be delivered
with various data telegrams:
Telegram content
Typ A*
Typ B* Typ C**
Current value
✓
✓
✓
Current date
✓
✓
Due date values
✓
✓
Current value
✓
✓
✓
Another 11 monthly values
✓
Status information 1
✓
✓
✓
Status information 2
✓
✓
✓
* Data telegram according OMS Spec.
** wM-Bus, manufacturer specific data telegram
LoRaWAN
TM
radio telegram
Protocol content
Interval
Serial number
(DevEUI)
once when logging into the
LoRaWAN
TM
network
Device-specific informa-
tion (firmware version,
LoRaWAN-version, device
type)
six-monthly
Due date value and date
[01.01.]
every year on due date
Unit of the medium, serial
number and if necessary
manufacturer of the con-
nected pulse meter per
input channel
2. Day after first
commissioning and
every six months
Szenario 1 (monthly)
Protocol content
Interval
Monthly value (previous month),
actual date and time
monthly
(beginning)
Mid-monthly value, current date
and time
monthly
(middle)
Scenario 2 (daily)
Protocol content
Interval
Daily values (previous day)
daily
Status information, actual date
and time
monthly