10. Readout Data logger

The EDC modules have an internal memory (data 

logger). The readout of the data which are not 

already transmitted in the above data telegrams is 

carried out by means of the optical head and related 

software.

Datalogger

EDC wM-Bus

EDC LoRaWAN

TM

Annual due date 
values

max. 16

2

Monthly values 

18  
plus 18 half-
monthly values

18  
plus 18 half-
monthly values

Daily values 

96

32

Quarter-hour values

96

--

11. Smart Metering functions

Self-monitoring

The module has an integrated battery status moni-

toring.

Tampering detection

It will be detected as soon as the scanning coils of 

the EDC module are affected by a magnet. In the 

event memory date and time of the event will be 

memorized.

Dismounting of module and meter detection

The detection is possible at all meters with grey 

register cap. A hall sensor detects here as soon as the 

EDC module was dismounted from the register. The 

event memory stores the date and  time of the event.

Leakage detection

If over a period of 24 h (96 quarter hour values) the 

flow value is never zero, than this indicates a leak. 

The EDC module sets corresponding bits.

If the flow rate remains zero during one quarter of an 

hour (before reaching 96 quarters of an hour with no 

flow) the algorithm restarts.

If 96 quarters of an hour were running with flow, 

leakage remains set until during 8 quarters of an 

hour in a row the flow remains zero. The event 

memory stores the date and time of the event.

Meter Stop detection (blockade)

If no meter progress will be detected by the EDC 

module over a period of 4 weeks, meter stop 

(blockade) is detected. The blockade deemed to be 

revoked if a meter reading difference of > 10 liters 

occurs in a quarter of an hour.

Meter oversized detection

Meter is oversized when the flow rate never exceed 

0,1*Q

3

 (10% of Q

3

). This is averaged over a 15-minute 

period. It is counted how many times the flow rate 

of 10% of Q

3

 is not achieved. If the flow rate is not 

reached after 30 days “meter oversized” is detected.

If once a flow rate of > 10% from Q

3

, averaged, is 

reached by a quarter of an hour, the detection is per-

manently disabled and the status "meter oversized" 

deleted. The event memory stores the date and time 

of the event.

Meter undersized detection

If the flow rate is continuously higher as Q

3

 (perma-

nent flow) over a 6-hour period, this  indicates an 

undersizing of the meter and the message “meter 

undersized” will be detected. This is averaged over a 

15-minute period. The event memory stores the date 

and time of the event.

Pipe burst detection

For EDC modules with M-Bus and Pulse: “Pipe burst” 

is detected when the flow rate has exceeded a given 

value (> 30% of Q

3

) during a 30-minute  period. This 

is averaged over a 15-minute period.

The event memory stores the date and time of the 

event.

Reverse water flow detection (wrong assembly)

If after installing, the EDC module detects that the 

meter is running backwards each ¼ hour for 12 

hours , reverse water flow is detected (wrong 

 

assembly). If the meter runs forward for 4 hours,  

the message shall be considered as finished.

Содержание Electronic Data Capture Module

Страница 1: ...lerstandsnachbildung aufgrund einer mechanischen Impulsz hlung Die Abtastung der Modulatorscheibe des Z hlwerks erfolgt elektro nisch und ohne R ckwirkung auf das Z hlwerk Die Elektronik erkennt auftr...

Страница 2: ...Moduls Einstellung der Impulsl nge ms Einstellung der Ausgangs Impulswertigkeit Bei der wM Bus Variante erfolgt die Aktivierung des Funksignals automatisch sobald die Funktion pulse enabled eingeschal...

Страница 3: ...tatusinformation 1 Statusinformation 2 Datentelegramm OMS konform Sendeintervall 20 Sek wM Bus herstellerspezifisches Telegramm Sendeinter vall 15 Sek Datentelegramminhalte LoRaWANTM Telegramminhalt I...

Страница 4: ...odus B2 Vorw rts und R ck w rtspulse Flie richtung offen vorw R ckw rtspulse werden durch Unterdr ckung der ent sprechenden Anzahl von Vorw rtspulsen ausgeglichen Funktion der Ausg nge der Impulsmodul...

Страница 5: ...Wenn ber einen Zeitraum von 4 Wochen kein Z hlerfortschritt vom EDC Modul erkannt wird wird Z hlerstillstand Blockade erkannt Die Blockade gilt als aufgehoben wenn in einer Viertelstunde eine Z hlerst...

Страница 6: ...ler zur ckgef hrt werden Unsere Gesch ftsprozesse sehen in der Regel vor dass wir bzw die von uns eingesetzten Fachfirmen Altger te inklusive Batterien und sonstigem Zubeh r nach deren Austausch bzw E...

Страница 7: ...counting The pulse detection of the register s modulator disc occurs electronically and without retroaction on the reg ister The electronics detects reverse pulses which will be computed internally so...

Страница 8: ...odule Setting of the pulse length ms Setting of the output pulse value Activation of the wireless M Bus radio signal per forms automatically as soon as the function pulse enabled is activated and the...

Страница 9: ...interval 20 sec wM Bus manufacturer specific data telegram Transmission interval 15 sec Data telegram contents LoRaWANTM Telegram contents Interval Packet Serial number DevEUI EDC module once at join...

Страница 10: ...orward pulses Reverse pulses Mode B2 Forward and reverse pulses Flow direction open forward Reverse pulses are reduced by the corresponding number of forward pulses Function of the pulse modules outpu...

Страница 11: ...date and time of the event Meter Stop detection blockade If no meter progress will be detected by the EDC module over a period of 4 weeks meter stop blockade is detected The blockade deemed to be revo...

Страница 12: ...possible if old equipment which contains batteries or other acces sories are disposed Therefore please contact the department of your lo cal authority which is responsible for waste disposal Alternat...

Отзывы: