Technical data multidata

Temperature range 

°C  1 - 150

Temperature difference range 

K   3 - 120

Display 

 

 Multifunctional LCD, 8-digit, floating

Display unit  

 

MWh, kWh, GJ, MJ

Interface flow sensor 

 

Models with contact pulsers or active pulser

 

 

(no Namur or Opto), passive max. 1Hz / active max. 100 Hz

Temperature sensor connection 

 

PT500, optional PT100, PT1000

Max. cable length 2-wire 

 

12,5 m (PT500), 2,5 m (PT100), 20 m (PT1000)

Max. cable length 4-wire 

 

20 m

Interfaces 

 

optical, optionally ZR-Bus, M-Bus, RS-232, 

 

 

remote readout outputs

Ambient temperature  

°C  5 - 55

Power supply  

 

Battery 3.6 V Lithium, optionally mains supply 230 V

Battery lifetime  

 

6 years, optionally 11 years

Protection class  

 

IP 54 / IP 65, acc. to DIN 40050

Mechanical/electro-magnetic class    

M1/E1

Accuracy class  

 

3

Measuring cycle dynamic 

 

40s/30s/10s

Содержание 08765432

Страница 1: ...multidata Installation and operating manual Electronic energy calculator for heat meters with 2 inputs outputs optionally with M Bus RS 232 and RS 485 All that counts EnergyMetering...

Страница 2: ...EU The duration of initial verification validity in Ger many remains 5 years for heat meters After this period has expired the measuring device may no longer be used for billing in commercial use The...

Страница 3: ...or 5 Symbol Status Event Flow existent Attention Check system device for errors Data transmission Emergency operation Exchange device External power supply Code Error Event 1 Short circuit return sens...

Страница 4: ...ure sensor connection PT500 optional PT100 PT1000 Max cable length 2 wire 12 5 m PT500 2 5 m PT100 20 m PT1000 Max cable length 4 wire 20 m Interfaces optical optionally ZR Bus M Bus RS 232 remote rea...

Страница 5: ...ance approx 10 nF Input resistance approx 850 kOhm 100 Hz Version fmax 30 Hz Pulse duty factor 1 1 Input capacitance approx 2 5 nF Input resistance approx 850 kOhm fmax 1 Hz Pulse duty factor 1 1 to 1...

Страница 6: ...nds to the last position of the as sociated display value Example Output 1 energy output Energy display XXXXX XX MWh Last position 0 01 MWh 10 kWh Output pulse 10 KWh The calculator can be ordered wit...

Страница 7: ...lose valves and release pressure before instal lation General Information Take care of the display must readable at all times to avoid malfunctions due to other interfer ences do not install fluoresce...

Страница 8: ...e sensor cables are marked with colors red supply blue return Do not buckle extend or shorten the wires Do only use paired sensors with the same se rial number on it At 2 wire systems the cable length...

Страница 9: ...time can be checked in the display level 3 After having reached the date the battery has to be replaced if needed Operation test Check the calculator for any error codes in the display after installat...

Страница 10: ...TR 71 GND 72 Tx 73 Rx 74 RS 485 UB 71 GND 72 A 73 B 74 Switch Connection 2 wire Connection 4 wire If water meters with a potential free reed contact are connected to the inputs the connection can be m...

Страница 11: ...number Serial number input 1 Serial number input 2 Energy main display Cooling in change iover versions Volume Volume external input 1 Volume external input 2 Segment test Supply temperature Return t...

Страница 12: ...ated resp switches to the sub menu Hold down the button H un til the device switches to an other level or switches back from the sub menu Note Depending on your meter s model its displays can differ i...

Отзывы: