background image

Reassembly

9

These instructions should be thoroughly
read and understood before starting
reassembly.

General instructions that should be

observed to ensure correct reassembly 
of the pump are as follows:

• Using a solvent such as

trichloroethane or chloroethene Nu, 
clean all parts that are to be used in the
reassembled pump.

WARNING

: Use extreme care when using

any solvent. Prolonged contact with the
liquid or inhalation of the vapor can cause
serious health problems.

• During and between each of the

assembly steps, 

manually turn the

metering gears to ensure that they are
free turning. 

If binding occurs at any time

during assembly, 

determine 

the cause

and 

correct it before 

proceeding further. 

A tiny nick, burr or foreign particle can
extensively damage a valuable part if
allowed to remain. Never use excessive
force in assembling or turning a pump. If
properly aligned, the pieces will fit easily
into the plate, and the drive shaft will turn
freely. 

All seals, O-rings and fasteners

must be replaced with new parts prior
to assembly.

• Use a soft-jawed vise to hold the

pump during reassembly.

• Before installing screws, lubricate

their threads with DAG Dispersion 154,
Felpro C-100, or similar heat-resistant
lubricant, and torque to prescribed values
as shown on the table on page 10.

1) On 3.0 cc/rev and smaller pumps,

place a gear key on each shaft and slide
each gear onto its shaft, engaging the key.

2) Slide the gear shafts into the center

plate, taking care not to damage the gear
teeth. On 3.0 cc/rev and smaller pumps,
note that each shaft has a larger diameter
end. These larger ends must be on oppo-
site sides of the pump for the bearing
grooves to align properly.

3) Gently slide the gear shafts so that

the rear ends of the shafts protrude from
the rear of the center plate. On the 3.0
cc/rev and smaller pumps, take care not
to slide the shafts out of the gears and
allow the keys to drop out of the shafts.

4) Slide a bearing onto the drive shaft,

taking special care to select a bearing
with the proper groove configuration (and
with the proper ID on the 3.0 cc/rev and
smaller pumps). Slide the matching bear-
ing onto the driven shaft, taking care to
select a bearing with the proper groove

configuration. Set the flats on the circum-
ference of the bearings against each
other, and gently slide the bearings and
shafts into the center plate. Slide them far
enough through the center plate to allow
the drive shaft to protrude out on the front
side and allow the front bearings to be
installed. See D-bearing orientation
schematic on page 8.  

5) Install the front bearings in the

same manner as the rear bearings, and
slide the bearings and shafts back into
the center plate so that the gears are
roughly in the center of the center plate.

6) For the 20 cc/rev and smaller

pumps, the bearings should be allowed to
protrude very slightly above the face of
the center plate before the cover plates
are installed. This will allow the bearings
to fit flush against the cover plates as
there are no bearing screws on these
smaller pumps. For 20 cc/rev and smaller
pumps, insert the bearing locating keys
on each side.

7) At this point make certain again

that there is no foreign matter on the faces
of the cover plates or on the faces of the
center plate. An accidental smudge of
thread lubricant can cause the small
pumps to bind.

8) Place the front cover plate on the

pump (and center on pump), checking
one more time that the configuration of the
bearing grooves is correctly oriented for
the inlet and discharge ports of the pump.
Insert the lubricated cover plate screws
into the pump and tighten them finger
tight only. Repeat for the rear cover plate.

9) On the 40 cc/rev and larger pumps,

insert the bearing retainer screws and
tighten them finger tight at this time.  

10 Torque down the cover plate

screws in a crisscross pattern, taking
them first to 1/4 the recommended torque
value, then to 1/2, to 3/4 and finally to
their full recommended torque value.

11) Torque down the bearing retainer

screws in the same manner as the cover
plate screws. (Install C-Rings if applicable.)

12) Fit the Rheoseal seal housing to

the shaft. Loosely install but do not torque
down the seal housing screws, as this will
allow the lip seal to properly center the
housing.

13) Install the lip seals, using the

special Zenith installation tools as follows
to prevent damaging the seal. Install the
lip seals with the open face toward the
body of the pump. Slide the installation

Содержание Pumps

Страница 1: ...Zenith Pumps Installation Care and Maintenance Zenith Polymer Extrusion Gear Pumps PEP II Series Gear Pumps...

Страница 2: ...critical issues in the diverse plastics industry The Zenith gear pump optimizes the extrusion process by allowing the screw to melt and homogenize the polymer As the pump generates the needed pressur...

Страница 3: ...and bottom of the center plate for the mounting of heat plates and for the mounting of the pump to its stand Thermocouple wells 1 8 27 NPT are located on the body of the pump A Zenith Rheoseal assembl...

Страница 4: ...1 KEY EXTERNAL PUMP PUMP DIMENSIONS MAX APPROX CAPACITY A B C D E F G H I J TORQUE WEIGHT 0 16 3 000 3 000 2 860 1 400 2 400 1 960 0 750 1 4 1 500 0 125 80 9 0 3 3 000 3 000 2 860 1 400 2 400 1 960 0...

Страница 5: ...I J TORQUE WEIGHT 5 3 250 3 250 3 250 1 125 2 875 2 125 0 500 1 4 1 875 0 750 1225 10 10 4 000 4 000 4 000 1 188 3 375 2 615 0 625 5 16 2 344 1 000 2085 18 20 4 750 5 000 5 000 1 188 3 750 3 300 0 75...

Страница 6: ...ture thread lubricant such as DAG Dispersion 154 Felpro C 100 or equivalent 2 Place the top heat plate on the pump then place the insulation jacket on top of the heat plate Install and tighten the bol...

Страница 7: ...nces As with any other Zenith pumps PEP II pumps may be returned to Zenith for complete rehabilitation as necessary This procedure may be desirable if only a few pumps are involved If a large number o...

Страница 8: ...te assembly Again soaking the parts in lubricating penetrating oil or other non damaging solution will help ease the disassembly Do not force the parts out one side with a hammer or arbor press 7 Slid...

Страница 9: ...he driven shaft taking care to select a bearing with the proper groove configuration Set the flats on the circum ference of the bearings against each other and gently slide the bearings and shafts int...

Страница 10: ...gently press the lip seal into the Rheoseal housing Do not attempt to press on the lip seal with screwdriver or other pointed object as this will damage the seal Do not press the lip seal all the way...

Страница 11: ...rrent and speed settings Check all drive couplings 3 Process conditions changed Check process conditions for proper melt temperature pres sures viscosities and materials 4 Entrained particle Disassemb...

Страница 12: ...y of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the final selection of the products and systems...

Отзывы: