Zenith Hydro Tap Installation and Operating Instructions - 81467 - February 2005
Page 3 of 20
Read These Warnings First
Safety
Do not allow young children, handicapped or infirm persons, to use the Zenith
HydroTap without supervision.
Refrigerant
The Zenith HydroTap Chilling unit contains 134A refrigerant under pressure. No
part of the unit should be exposed to a naked flame. Maintenance of the
refrigeration unit must be carried out by an accredited service provider or
qualified refrigeration mechanic.
Qualifications
If any power cord or plug is damaged it must be repaired only by a qualified
technician. To avoid hazards, all installation procedures must be carried out by
a suitably qualified tradesperson. The power cord and general power outlet
must be in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water may discharge through a vent outlet at
the mouth of the tap. If the tap is not installed using the Font pedestal, ensure
the tap body is located so the tap outlet safely drains into the sink bowl area.
NOTE:
On startup, the controls take the system through a calibration process
which causes the unit to over-boil for a period of 90 secs. This is normal
operation, once this mode is completed the system reverts back to normal
operation.
Lifting
Take care when lifting the Zenith HydroTap undersink unit. Some units may exceed
safe lifting limits. Do not lift without assistance. The weights of the units are
given in the table under the heading “Installation Requirements”. Do not lift the
unit by the doors.
Airflow
The ambient temperatures this unit should operate within are 5ºC - 35ºC. Proper
air circulation must be provided. The system will operate satisfactorily only if
the recommended air gaps are provided, these are 65mm min rear clearance
and 50mm side clearance. An air vent is provided with each unit for high usage
applications, this must be installed in the top half of the cupboard door as a
matter of course. An optional fan kit is available and should be used to ensure
adequate ventilation. Make sure that the ventilation grilles of the undersink unit
are not obstructed.
Altitude (not HT boiling only series)
The Zenith HydroTap is equipped with a self-calibrating program which caters for
altitude adjustment.
Filter For models : BC, BD, BF
The Zenith HydroTap filter control is preset to 6000 Litres to provide trouble-free
flow and operation in most installations. Local water quality conditions may
require an alteration to this capacity. In areas where the water has a high
concentration of sediment, the preset litre capacity may be shortened to avoid
poor flow, taste or odour situations. In areas where the water quality is above
average, lengthening the preset capacity may be desirable, but not essential. If
any of these changes is needed, follow the instructions on page 11 or contact
your Zenith Service Provider.
Zip Hydrotap undersink assembly.
The appliance must be placed in a
horizontal position, as shown above.
The power point must be located within
reach of it’s cable. The appliance must be
positioned so that the plug is accessable.
Содержание HydroTap B100
Страница 17: ...Zenith Hydro Tap Installation and Operating Instructions 81467 February 2005 Page 17 of 20 Notes ...
Страница 18: ...Page 18 of 20 Zenith Hydro Tap Installation and Operating Instructions 81467 February 2005 Notes ...
Страница 19: ...Zenith Hydro Tap Installation and Operating Instructions 81467 February 2005 Page 19 of 20 Notes ...