Visible Tundish

Vent line

Installation Procedures 

Continued

Step 3 – Connecting

THE FOLLOWING PROCEDURE IS TO BE DONE BY AN AUTHORISED 

INSTALLER ONLY.

a) Plumbing

For exposed plumbing connection, connect the cold water inlet pipe 

from the base of the heater directly to the 1/2” or 12.7 mm compression 

fittings.
For concealed plumbing connections, connect the cold water pipe 

through the rear of the chassis using a 1/2” or 12.7 mm capillary elbow 

(# 63 Swivel Elbows).
Cold water pipes must be flushed before connection to the inlet. Any 

clogging due to sediment or fines will adversely affect the operation of 

the heater.
It is recommended that the heater be installed with a stop cock which 

allows it to be isolated from the mains supply for servicing as requried 

by AS3500. 

Water pressure requirements:

 

Minimum - 70 kPa, maximum - 700 kPa.

Warning: If pressure is likely to exceed 700 kPa, a pressure 

limiting valve must be installed in the cold water supply line. Zenith 

recommends a valve rated at 350 kPa for this application. 

b) Venting

A vent at the base of the heater must be plumbed to a safe visible 

location as, under certain conditions, it may discharge cold or boiling 

water and/or steam.
For exposed vent plumbing, connect vent outlet from the base of heater 

to a 1/2” or 12.7 mm pipe which has a continuous fall, is no more than 3 

metres long, has no more than 3 right angle bends, and discharges to a 

waste water drain.
For concealed vent plumbing, connect plumbing to the vent outlet 

from the heater rear using a elbow protruding 45 mm from the wall.
Alternatively attach a tun dish to the wall as shown and plumb away to 

waste.
Tun Dish part numbers:  

Wall Mounted Tun Dish- 99017NZ and Benchtop Tun Dish- 99018NZ.

c) Electrical

Do not turn the power ON yet. Power is only to be turned on after the 

cover and the tap is fitted and the unit is filled with water. 

This unit is designed for connection to 220-240 volt AC power supply 

via either a concealed electrical connection or an exposed electrical 

connection.
For an exposed electrical connection, the pre-fitted flex and plug 

cable is plugged into the PCB as shown. Use a standard 

10 amp 220- 

240 volt power outlet within 1500 mm from the heater with adequate 

power for the unit.

Concealed power and water 

are connected through rear.

Electrical

 

Exposed power and water 

are connected through base.

Содержание Econoboil 301642

Страница 1: ...804544NZ 03 17 v1 00 Page 1 of 12 Zenith Econoboil Installation and Operating Instructions 301642 Zenith Econoboil 1 5 litre White 303642 Zenith Econoboil 3 0 litre White 305642 Zenith Econoboil 5 0...

Страница 2: ...al capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety For products sold in...

Страница 3: ...er supply Do not use strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5 C when the heater...

Страница 4: ...ion the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less tha...

Страница 5: ...g A vent at the base of the heater must be plumbed to a safe visible location as under certain conditions it may discharge cold or boiling water and or steam For exposed vent plumbing connect vent out...

Страница 6: ...top and bottom Lock nut Installation Procedures Continued For a concealed electrical connection disconnect the pre fitted flex and plug cable at the PCB connector and discard Connect the concealed po...

Страница 7: ...ust be manually returned Pull handle down for water flow than release Tap Operation Zenith Econoboil is fitted with a two way safety tap for instant boiling water For instant boiling water gently pull...

Страница 8: ...Earthing Continuity Verification Warning this appliance must be earthed Following remedial service the earthing continuity of the heater must be checked by a qualified technician using an appliance te...

Страница 9: ...Zenith Econoboil Installation Operating Instructions 804544NZ 03 17 v1 00 Page 9 of 12 Wall Mounting Template Dimensions ROG QOHW 9HQW WHUQDO 3OXPELQJ OHFWULFDO LULQJ QWHUQDO 3OXPELQJ 3RVLWLRQLQJ SLQ...

Страница 10: ...4454NZ Cistern Tank 15 94455NZ Ball Valve assy 16 94456NZ Cistern Gasket 17 94457NZ Cistern Lid EB AB 18 93118NZ Elbow Stem 1 4 19 90100NZ Grommet Cistern to Tank 20 94458NZ Overload 21 94459NZ Side r...

Страница 11: ...Zenith Econoboil Installation Operating Instructions 804544NZ 03 17 v1 00 Page 11 of 12 Exploded View Diagram...

Страница 12: ...out prior notice Images in this booklet have been modified and may not be true representations of the finished goods The standard cup referred to in this publication is 167 ml 6 fl oz 2017 Zenith Heat...

Отзывы: