6 Testing
Testing should be done as required.
6.1 Calibration and Testing
Testing of the operational functionality of the 8300 MkII is done using a foghorn.
NOTE:
The 8300 MkII automatically and continuously tests both the display and microphone unit.
In the event of an error, the error will be displayed by the LEDs in the web interface or in the syslog server
(if configured).
Foghorn activity should be in 3-second bursts with at least 10 seconds between each burst.
NOTE:
If the microphone unit is not correctly mounted, the display unit can compensate for this by adding an
offset to the detections.
Check the calibration mode or additional options.
7 Maintenance
All maintenance options for the 8300 MkII are completed in the
Additional options
page of the web interface. The
maintenance options are as follows:
•
Upgrade or view the current firmware version.
•
Perform a factory reset.
To perform a firmware upgrade:
1. Click the
Update firmware
button.
2. Select the firmware upgrade package in the dialog box
NOTE:
When the firmware upgrade is complete, the unit will automatically restart
To perform a factory reset:
1. Click the
Factory reset
button.
2. Click
Yes
in the dialog box.
NOTE:
All configuration options will be reset to the factory default, including the network IP address setting.
The default network IP address (172.31.0.100) must be entered manually in a web browser to regain access to
the web interface.
If the original default address was not changed, the web interface will refresh automatically.
When the reset is complete, the unit will automatically restart.
To perform a reboot:
• Click the
Reboot
button.