3.3  Product Specification Junction Box                             

Dimensions (W/H/D):

120 mm / 78 mm / 104.5 mm

Weight:

0.35 kg

Ingress Protection:

IP-67

Temperature Operating:

-50 to + 90 °C

Figure 11: Junction Box - 12-way with screen (optional)

Содержание PHONTECH SR 8300 MkII

Страница 1: ...USER MANUAL 8300 MkII Sound Reception System MARITIME COMMUNICATION SYSTEMS...

Страница 2: ...it 4000019415 P 8301 MkII Microphone Unit 4000019416 Junction Box for Microphone Unit 4000019634 8300 MkII Sound Reception Kit 4000019470 Publication Log Rev Date Author Status Comments 1 0 13 8 2019...

Страница 3: ...Electrical Connections 16 5 Operating Instructions 18 5 1 Operational Modes 18 5 1 1 Normal Mode 18 5 1 2 Manual Listen Mode 19 5 1 3 Calibration Detection Mode 20 5 1 4 LED Test Mode 20 5 2 Network O...

Страница 4: ...ting 37 6 1 Calibration and Testing 37 7 Maintenance 37 8 Test and Maintenance Records 38 9 Troubleshooting 39 9 1 Microphone Surveillance Failure 39 9 2 LED Surveillance Failure 39 9 3 Foghorn Detect...

Страница 5: ...mission IMO International Maritime Organization IP Internet protocol address ISO The International Organization for Standardization kB s Kilobytes per second kHz Kilohertz LED Light emitting diode MED...

Страница 6: ...nterfaces Part 1 Single talker and multiple listeners IEC 61162 2011 450 Maritime navigation and radio communication equipment and systems Digital interfaces Part 450 Multiple talkers and multiple lis...

Страница 7: ...appears on the display with an accuracy of 10 degrees The 8300 MkII has adaptive background noise canceling to filter out unwanted sounds though advanced digital signal processing Multiple display un...

Страница 8: ...s required according to the International Regulations for Preventing Collisions at Sea 1972 The system works by listening and detecting the direction of a foghorn The 8300 MkII system is always listen...

Страница 9: ...85 kg Temperature Operating 15 to 55 C Temperature Storage 15 to 55 C Humidity 93 40 C Ingress Protection IP 22 console mounted Compass Safe Distance 2 2 m Interfaces 100 Mbit Ethernet Mute closing co...

Страница 10: ...10 User Manual 8300 MkII Sound Reception System Figure 5 P 8300 MkII dimensions top depth width Figure 6 P 8300 MkII dimensions...

Страница 11: ...upply Voltage Powered by 8300 MkII 5VDC Dimensions W H D 317 mm 338 mm 317 mm Weight 3 95 kg Temperature Operating 25 to 55 C Temperature Storage 25 to 70 C Humidity 93 40 C Ingress Protection IP 56 C...

Страница 12: ...12 User Manual 8300 MkII Sound Reception System Figure 10 P 8301 MkII Mounting Bracket Figure 9 P 8301 MkII Dimensions Mounting Bracket...

Страница 13: ...Sound Reception System 3 3 Product Specification Junction Box Dimensions W H D 120 mm 78 mm 104 5 mm Weight 0 35 kg Ingress Protection IP 67 Temperature Operating 50 to 90 C Figure 11 Junction Box 12...

Страница 14: ...n appropriate location bearing the following in mind Install the microphone unit in a location far away from noise and any mechanical vibration sources The microphone unit should not be installed next...

Страница 15: ...web interface Figure 14 8300 MkII dimensions screw hole positioning To mount the P 8300 MkII Display Unit 1 Find the appropriate location for mounting bridge or similar structure 2 Degrease the conso...

Страница 16: ...isplay unit When connecting the microphone unit to the display unit the cable must be terminated in the 11 pin microphone connector on the back of the display unit The cable must be shielded and conta...

Страница 17: ...d can be supplied by Zenitel 3 To comply with EMC requirements all cable shields must be safely connected to the chassis as shown 4 The mute signal to the P 8300 MkII display unit A closing contact no...

Страница 18: ...the volume control Differences in the level of the input can be perceived in the clarity of the signal compared to the background noise As a reference the expected level for a whistle with a fundamen...

Страница 19: ...at all times in this mode To activate the manual listen mode do the following 1 In the normal mode press and hold the control button for 5 seconds NOTE When active the light around the control button...

Страница 20: ...e control button is not pressed or rotated for 30 seconds Use the calibration detection mode to adjust the offset display You would for example do this to adjust the offset of an incorrectly mounted P...

Страница 21: ...39 192 0 9 60009 USR2 239 192 0 10 60010 USR3 239 192 0 11 60011 USR4 239 192 0 12 60012 USR5 239 192 0 13 60013 USR6 239 192 0 14 60014 USR7 239 192 0 15 60015 USR8 239 192 0 16 60016 NOTE These tran...

Страница 22: ...ured transmission group such that the slave s can receive them The SRS sentence has three additional parameters Description Type Direction of the detection An integer between 0 and 359 inclusive Score...

Страница 23: ...VOL proprietary sentence 5 2 1 3 HBT Sentence The P 8300 MkII sends a heartbeat HBT sentence once every 60 seconds This sentence is sent to the MISC transmission group It is equal to the standard HBT...

Страница 24: ...atus parameter at the end of the sentence NOTE Refer to IEC 61162 1 standard for more information regarding the two variants and the DDC sentence NOTE The two dashes before the DDC message represents...

Страница 25: ...g watchdog because all required tests have not been passed Mask Message informs that the unit will restart due to a failing watchdog test Mask is replaced with a bitmask in hex that identifies the fai...

Страница 26: ...oubleshooting NOTE You can adjust the display timing in seconds in the web interface 5 6 Detecting a Sound Signal When the P 8300 MkII detects a sound signal and determines the direction of the signal...

Страница 27: ...n System 5 7 Detecting Multiple Sound Signals The P 8300 MkII is able to detect multiple sound signals simultaneously Figure 25 Detecting multiple sound signals 0 and 310 Figure 26 Detecting multiple...

Страница 28: ...t the volume do the following 1 Press and release the control button to select the volume adjust mode 2 Rotate the knob clockwise to increase and counterclockwise to decrease the volume To adjust the...

Страница 29: ...ss into any web browser The default IP address is 172 31 0 100 with a netmask of 255 255 255 0 You will be prompted to enter your username and password the first time you access the web interface The...

Страница 30: ...30 User Manual 8300 MkII Sound Reception System Figure 29 Home screen status OK acknowledge messages Figure 30 Home screen status Failed Acknowledge messages...

Страница 31: ...log protocol By enabling the syslog network logging the Phontech 8300 MkII display unit will send information and error messages over the Ethernet network Syslog messages can either be sent to the IEC...

Страница 32: ...32 User Manual 8300 MkII Sound Reception System Figure 31 Network settings overall configuration...

Страница 33: ...ns but are more susceptible to false detections To configure the signal to noise ratio 1 Use the slider or manually type in a value 2 Click the Save settings button Figure 32 Audio settings signal to...

Страница 34: ...Format or structural error in the TAG block TAG checksum Checksum errors in the TAG block TAG syntax Syntax error in the TAG block such as illegal characters or fields TAG framing Framing errors in t...

Страница 35: ...t be connected to the microphone unit but will receive detections and sound from the master unit over Ethernet There may be multiple slave units in an installation Alignment offset Use this setting to...

Страница 36: ...36 User Manual 8300 MkII Sound Reception System Figure 34 Additional options including maintenance update firmware reset and reboot...

Страница 37: ...ptions for the 8300 MkII are completed in the Additional options page of the web interface The maintenance options are as follows Upgrade or view the current firmware version Perform a factory reset T...

Страница 38: ...38 User Manual 8300 MkII Sound Reception System Date M T Signature Inspection M Maintenance T Test 8 Test and Maintenance Records Record all test and maintenance activities below...

Страница 39: ...onnected to the display unit on the left side of the Mute connection A description of all the connectors is displayed on the back of the unit If the web interface indicates that all microphones are do...

Страница 40: ...300 MkII and are unclear about your warranty period contact Zenitel All Zenitel products are warranted against factory defects in materials and or workmanship during the warranty period unless otherwi...

Страница 41: ...by an authorized Zenitel service agent CAUTION Improper maintenance may destroy the functionality and or performance of this product Spare Parts Keep the original packaging If the 8300 MkII needs to...

Страница 42: ...tel The company s Quality Assurance System is certified to meet the requirements in NS EN ISO 9001 Zenitel reserves the right to modify designs and alter specifications without notice ZENITEL PROPRIET...