ICX 500 Gateway
Doc.no.A100K12202
Page 7
Console Port
RS232
RJ-45
ICX-500 RS232 port is the RJ45 part of the dual connector
RS232/USB used for the integration with third party system
over serial bus communication
USB
USB A
USB micro-B
ICX-500 features one USB A and one USB micro-B connector
*For Future Applications
Fault Relay
3 pole terminal
block
Fault relay is used to indicate system status together with Fault
LED
SD Card
Micro SD Card
Used for external storage or system recovery (Behind
protection lid)
Factory
Default
Button
Tact switch
Used for resetting ICX-500 to factory default settings (Behind
protection lid)
2.2. Network
The ICX-500 Gateway has two RJ-45 ethernet ports for IP communication. Ethernet port 0 (Eth
0) is by default configured as a management port, allowing connection to the embedded web
server (ICX Web) and connection of the PC configuration tool AlphaPro.
Default IP addresses:
•
Eth0: Static IP address 169.254.1.5
•
Eth1: Obtains IP address automatically (DHCP)
2.3. Start up and initial configuration
•
Power up the IXC-500 Gateway
•
Watch the LEDs. During start-up the Power LED and the Fault LED will be lit. The system
uses approx. 20 seconds to start up. When up and running, the green status LED will start
flashing.
•
The ICX-500 comes with an embedded web server (ICX Web), which provides functions for
system configuration, monitoring and upgrade. Initial connection is done by connecting a
laptop to Eth port 0, open a web browser (e.g. Firefox or Chrome), and log on to the web
server using IP address 169.254.1.5. (Default Username/Password = admin/alphaadmin).
Zenitel recommends do not change Default IP and username and password of Eth port 0.
•
Once initial configuration is done use Eth port 1 for connecting to Local Network.