background image

 
 
 
 
 
 
 
 
 

  ZS-6822A  Series   

  LAN/DIO  Adapter

   

 

instruction manual

 

 
 
 
 
 
 
 
 
 
 
 
 
 

1st edition 

 
 
 
 
 

 

2-13-37 Honmachi, Fuchu City, Tokyo 183-0027 

Phone: +81-42-368-2126 Fax: +81-42-364-0067 

URL 

https://www.zenisu.co.jp/

 

Содержание ZS-6822A Series

Страница 1: ...1 ZS 6822A Series LAN DIO Adapter instruction manual 1st edition 2 13 37 Honmachi Fuchu City Tokyo 183 0027 Phone 81 42 368 2126 Fax 81 42 364 0067 URL https www zenisu co jp...

Страница 2: ...ce Installer 6 5 How to install COM Port Redirector 9 5 1 Installation of COM Port Redirector 9 5 2 Virtual COM port setting 11 6 Operation 14 6 1 Transfer data method 14 6 2 Control Signals 15 6 3 In...

Страница 3: ...on to data a control line is provided to synchronize with an external device 3 Specifications 3 1 Operating environment Equipment with LAN port 3 2 LAN Standard IEEE802 3 Media type 10BASE T or 100BAS...

Страница 4: ...Small case low price Data connector 50 core flat cable 50 core flat cable Power supply DC4 75V to 5 25V 100mA or less DC4 75V to 5 25V 100mA or less Usage environment Temperature 0 C to 50 C Humidity...

Страница 5: ...5 3 5 Appearance and dimensional drawing ZS 6822AP PC board type ZS 6822AS small case type Dimensional drawing ZS 6822AP ZS 6822AS...

Страница 6: ...evice Installer If a warning message is displayed click OK ZS 6822A can be recognized the following screen will be displayed MAC address on the warranty card matches the displayed hardware address If...

Страница 7: ...7 Enter the value of the address you wish to set in the IP Address section and click Next When the following screen appears click Assign...

Страница 8: ...8 After a while the following screen is displayed and the setting is completed Click Finish It will be successful if the IP address has been changed correctly Quit Device Installer...

Страница 9: ...s www lantronix com products com port redirector This chapter is not necessary when writing user application programs in TCP IP or UDP IP 5 1 Installation of COM Port Redirector Downloaded from our HP...

Страница 10: ...tion and click the Next button Unless otherwise specified the installation destination can be left as is Click the Next button Installation will start Installation will start If the following screen a...

Страница 11: ...11 Close button Click the OK button Installation is now complete 5 2 Virtual COM port setting From the start menu select Lantronix CPR Manager to start it A screen like the one below will appear...

Страница 12: ...ill be added in Com Ports on the left side of the screen so select it and click Search For Devices the search is complete double click the item displayed in the Device List at the bottom of the screen...

Страница 13: ...13 After completing the settings select Com Port Save Setting The following screen will be displayed so select Yes The settings are now complete Close and exit the application...

Страница 14: ...de is used for data transfer and one character is converted to 4 bit binary code 4 bit binary LAN data 8 4 2 1 HEX 0 0 0 0 0 0 0 0 1 1 0 0 1 0 2 0 0 1 1 3 0 1 0 0 4 0 1 0 1 5 0 1 1 0 6 0 1 1 1 7 1 0 0...

Страница 15: ...3 to D0 of port 4 6 2 Control Signals A control signal is provided to synchronize with the connected device Signal name signal direction explanation STB OUT The adapter completes receiving all data fr...

Страница 16: ...data will remain in the missing area pulse output After receiving the data from the PC send the data to the port set for output Set data in 4 bit units in the order of high order and low order Output...

Страница 17: ...ve logic of the port 6 4 1 R command function Data is read from all ports that are set as inputs For example if 4 input ports are set the R command will send 8 bytes of data from the ZS 6822A format R...

Страница 18: ...at Dxxxx CR LF After D set port port port and port in this order x writes I for IN for input and O for OUT for output return value OK CR LF Setting complete NG CR LF Input output setting error setting...

Страница 19: ...continuous output The pulse width at the time of pulse output is set by the P command format Ux CR LF x is a number 0 for continuous output and 1 for pulse output return value OK CR LF Setting comple...

Страница 20: ...D6 29 30 D6 D7 31 32 D7 IN LAH 33 34 5V OUT STB 35 36 5V OUT TRG 37 38 5V OUT CLR 39 40 5V NC 41 42 GND NC 43 44 GND NC 45 46 GND NC 47 48 GND NC 49 50 GND Note PIN 34 36 38 and 40 are NC in the forme...

Страница 21: ...nder normal conditions of use in accordance with the instruction manual and other notes In the following cases the product will be repaired for a fee even during the warranty period Malfunction or dam...

Отзывы: