ZENER 8000-V Installation Manual
_
54
IM00165
Your ZENER 8000-V Setup Notes
Copy this page or complete in pencil
Date: ……………………………………
Site designator: ……………………………………………..
Serial No: ………………..……………
Parameter
User
Default
A06 Application:
<none>
B01 MOTOR VOLTS
*
B02 MOTOR AMPS
*
B03 MOTOR Hz
*
B04 MOTOR RPM
*
C01 MIN Hz
0
C02 MAX Hz
*
C030 ACCEL TIME
10.0 secs
C031 DECEL TIME
10.0 secs
C032 S TIME
0.01secs
C033 DUAL RAMP
DISABLED
C040 FLUX PLUS
0.00%
C041 HiSpd Flux+
DISABLED
C05 SLIP COMP %
0.00%
C06 AUDIBLE FREQ
AUTO
D01 CURRENT LIM
*
D020 I2t
*
D021 I2t zero Hz
*
D022 I2t CNR Hz
10.0 Hz
D03 REVERSE
DISABLED
D04 DC INPUT
DISABLED
D05 1 Phase Inpt
DISABLED
D060 SKIP SPEED
30 Hz
D061 SKIP RANGE
0 Hz
E01 COAST STOP
DISABLED
E02 DYNAMIC BRK
DISABLED
E030 ARs ALLOWED
0
E031 AR CLR TIME
1200 secs
E04 Reset by PF
DISABLED
E05 Motor Resync
DISABLED
E06 LC CONTROL
DISABLED
E0701 SOLAR FXN
DISABLED
E070 RUN MODE
OFF
E071 Restart DC
550V
E072 Restart DLY
60 secs
E073 Lo Radiance
530V
E074 Hi Radiance
CONSOLE
E075 Vmp Volts
550V
E076 Display var
PV-A
E077 Lo Solar t
0 secs
Parameter
User
Default
E078 SFC time
1 sec
E079 SFC Ext sel
OFF
F010 REMOTE REF
AI(10,11)
F011 REMOTE Inpt
6
(see
I11
)
D4(5)
F0120 MODE1 REF
AI(10,11)
F0121 MODE1 Inpt
OFF
F0122 MODE1 text
"U MODE 1"
F0123 MODE1 cfg
Reference only
F0130 MODE2 REF
AI(10,11)
F0131 MODE2 Inpt
OFF
F0132 MODE2 text
"U MODE 2"
F0133 MODE2 cfg
Reference only
F02 LOCAL
CONSOLE
F030 ESO REF
F105 Preset 6
F031 ESO Input
6
(see
I08)
OFF
F032 ESO RAMP
10.0 secs
F040 JOGFWD REF
F105 Preset 6
F041 JOGFWD Inpt
6
(see
I09)
OFF
F050 JOGREV REF
F105 Preset 6
F051 JOGREV Inpt
6
(see
I10)
OFF
F060 Sel Method
Multiplexed
F061 USER REF 1
AI(10,11)
F062 USER REF 2
CONSOLE
F0630 Selector 1
OFF
F0631 Selector 2
OFF
F0632 Selector 3
OFF
F0633 Selector 4
OFF
F0634 Selector 5
OFF
F0635 Selector 6
OFF
F0636 Selector 7
OFF
F0637 Selector 8
OFF
F070 AI Function
Average fxn
F071 AI in 0 sel
ZERO_REF
F072 AI in 1 sel
ZERO_REF
F073 AI in 2 sel
ZERO_REF
F080 PERSISTENT
DISABLED
F081 STOP RESET
DISABLED
F09 COMMS PRESET
60.00%
F1001 PRESET1 units
%
6
Alias name for the parameter
Содержание 8000-V
Страница 1: ...ZENER VARIDRIVE SOLUTIONS ZENER 8000 V Installation Manual Document IM00165 Printed 27 February 2019...
Страница 6: ...Contents iv IM00165...
Страница 32: ...ZENER 8000 V Installation Manual _ 26 IM00165 Extended Features Option Wiring...
Страница 68: ...ZENER 8000 V Installation Manual _ 62 IM00165...
Страница 69: ...ZENER 8000 V Installation Manual IM00165 63...