TABLE. ELECTRICAL SYSTEM TROUBLESHOOTING (cont'd)
Trouble
Cause
Remedy
STARTER
Motor fails to operate.
Low battery charge.
Defective or improper
wiring or loose
connections.
Defective starter solenoid
or control switch.
Check and recharge if
necessary.
Refer to electrical wiring
diagram and check all
wiring.
Replace faulty unit.
Low motor and cranking
speed.
Worn, rough, or improperly
lubricated motor or starter
gearing.
Same electrical causes as
listed under "Motor fails to
operate".
Disassemble, clean,
inspect, and relubricate,
replacing ball bearings if
worn.
Same remedies listed for
these troubles.
ELECTRICAL LOADS (AMPS)
Equipment
Continuous
Intermittent
Battery solenoid
Voltage Regulator
Clock
Hour meter
Fuel Gauge
Fuel Pressure
Oil Temperature
Voltmeter
Ammeter
Aux. fuel pump
Flap Actuator
Trim Actuator
(if applicable)
Stall Warning
Options
Turn and Bank
Position Lights
Strobes
Instrument Lights
Landing Lights
Pitot Heat
.65
3.0
.1
.1
.1 (ea)
.1
.1
.1
.1
.1
2.0 (ea)
7.0
.33 (ea)
10.0
5.0
5.0
1.0
.1
7.0 (ea)
10.8
Oct-00