![Zenair CH2000 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/zenair/ch2000/ch2000_service-manual_3341215073.webp)
ZENAIR CH2000 SERVICE MANUAL
________________________________________________________________________
STALL WARNING - Right bottom of Fig. 23
The stall warning system consists of an electric buzzer located behind the roll over bar on
the cabin ceiling, and activated by the airflow closing the contact on the right wing leading
edge when the aircraft operates at a high angle of attack near the stall of the wing.
If the buzzer does not operate when lifting the contact: check the contact, the buzzer and
the breaker for proper operation.
The contact element on the wing leading edge is replaced by removing the blind rivets and
pulling it out. Reinstall with blind rivets at the same location to obtain the warning
(buzzer) 5 kts above the stall speed.
LANDING LIGHT REPLACEMENT - Located in the right wing Leading edge, near the
wing tip.
1. Remove the polycarbonate cover.
2. Remove the four screws of the retaining ring.
3. Change light bulb (GE #4509).
4. Reassemble and install in reverse order.
10.6
3 Apr 95