Zena 150 series Скачать руководство пользователя страница 8

4

the generator to its normal operating speed to allow the cooling fan to remove most excess
moisture from inside the case.  If available, compressed air can be used to good advantage
at this time to assist in the process of “drying” the generator.

4) After

 

Operating

 

in

 

Wet

 

Conditions

Excess water should be removed from the Welding Power Generator by operating the
vehicle’s engine briefly to allow the cooling fan to remove most excess moisture from
inside the case.  Excess water can be removed from the Control Handle’s internal
components by simply hanging the Control Handle so that its electrode holder points
“down”.  Moisture trapped in the handle or its components will drain out or evaporate.

D. DO

 

NOT…

!

use spray lubricants of any sort on any component; or

!

operate the unit in very dusty and or dirty conditions without insuring that cooling air
reaching the unit is as dust and/or contaminant free as possible; or

!

allow antifreeze compounds to contact system components without cleaning the
affected component with fresh water; or

!

allow accumulations of grease and/or dirt to form on system components; or

!

apply any sort of paint to any system component; or

!

clean system components with aerosol brake cleaners, carburetor cleaners, spray
degreasers, or other chemicals except as noted above in “Cleaning” above.

Содержание 150 series

Страница 1: ...ings Road Elmwood TN 38560 Phone 615 897 2011 Fax 615 897 2023 www zena net ZENA mobile welding system Power Generator Testing Cleaning for All ZENA Mobile Welders Utilizing Factory Installed ZENA Ser...

Страница 2: ...r modifications at any time without prior notice Copyright 2005 2007 2008 by ZENA Incorporated All rights reserved No part of this publication may be reproduced in any form or by any means without the...

Страница 3: ...1 ZENA Power Generator Care Maintenance 3 A Lubrication 3 B Wet Conditions 3 C Cleaning 3 D DO NOT 4 Cleaning Slip Rings Brushes 5 Step 1 Inspection Cleaning PRIOR to Removal from Drive Motor 5 Step...

Страница 4: ......

Страница 5: ...htness should be rechecked after the first few of hours of operation Electrical Function You can easily check for a component failure in the Power Generator by following the following procedure Discon...

Страница 6: ...using the generator in a charging generating application this is done by temporarily and briefly connecting one of the two control terminals to ground and the other to a source of DC voltage between...

Страница 7: ...with a high mineral content it should be rinsed off with fresh water as soon as possible after exposure Remove excess rinse water from the Welding Power Generator by using compressed air if available...

Страница 8: ...ging the Control Handle so that its electrode holder points down Moisture trapped in the handle or its components will drain out or evaporate D DO NOT use spray lubricants of any sort on any component...

Страница 9: ...ld detergent14 which is effective at removing cleaning grease oil After cleaning the generator should be rinsed with fresh water Excess water should then be removed by operating the generator s drive...

Страница 10: ...embly outside of the case the brushes can be easily pushed back into place by hand and then held in place by a straightened paper clip As the brush assembly is reinstalled the wire is threaded through...

Страница 11: ...case bolts are inserted and tightened Insert the four case bolts removed previously making sure if reassembling a model SR200 series generator not to forget to position the generator s four stainless...

Страница 12: ...telephone if available that we can uses if it is necessary to contact you IF YOU DO HAVE TO RETURN AN ITEM insure it and make sure that it is packed carefully and properly use our packaging materials...