The vacuum cleaner starts at the same power level it had
been working before it was turned off. Set the desired power
value (this function is only available in vacuum cleaners type
919.0) by pressing the power adjustment b/-
(9)
.
The vacuum cleaner is equipped with a power
level memory function. It is only available
in type 919.0 models. When you turn off the
vacuum cleaner using the ON/OFF button
(8), the power level is going to be stored in
memory. After the vacuum cleaner is turned
on next time, it is going to start working at the
same power level it had been working before it
was turned off.
The vacuum cleaner is equipped with the
adjustment function for LED brightness of
the power level indicator (10) and the clogged
air inlet indicator (12) situated on the control
panel. This function is available only in
vacuum cleaners type 919.0. To set demanded
brightness of LEDs you should simultaneously
press the power adjustment buttons + and –
(9), and then holding them down you should
turn on the vacuum cleaner by pressing the
“ON / OFF” button (8). The LED for power
levels 1, 3, and 5 turn on, and the motor
stays turned off. Next by pressing the power
adjustment b/– (9) you can respectively
increase or decrease the brightness of power
level indicator (10), and the clogged air inlet
indicator (12). It is not possible to change LED
brightness for the pump operation indicator
(6). After setting a desired LED brightness, it is
necessary to turn off the vacuum cleaner using
the ON/OFF button (8). In this way you leave
the LED brightness adjustment function mode,
and the set LED brightness level is stored.
The vacuum cleaner is equipped with a power
limiting function should the inlet opening be
clogged or the SAFBAG dust bag full. It is
manifested by a pulsing limitation of the motor
power and the lighting up of the clogged air
inlet indicator (12) while the vacuum cleaner
is operating at full power (type 919.0). In such
a case switch off the vacuum cleaner by
pressing the on/off button (8), unplug the
appliance and clear the tubes or replace the
SAFBAG dust bag.
SAFBAG dust bag disassembly/assembly
1
Remove the filtration unit from the container and pull out
the SAFBAG holder
(21)
.
2
Lift the SAFBAG tab and slide the dust bag from the
holder guide.
3
Slide the new SAFBAG tab all the way into the holder
guide as directed by the arrow printed on the bag until tab
locks in the guide.
D
4
Put the SAFBAG holder
(21)
in the container and cover
with the filtration unit in accordance with paragraphs
C2
and
C3
.
If the SAFBAG dust bag is not properly attached
to the holder, the safety lock will prevent
covering the container with the filtration unit.
VACUUM CLEANING WITH THE USE OF THE
WATER FILTER MODULE
1
Press and hold the container lid opening button
(2)
and
lift the container lid.
2
Insert the partition in the container. Make sure the
partition is inserted correctly in the container guide slots and
the safety lock is engaged.
3
Fill the container with 1,3–1,5 liter of water. The water
level should be in the range marked on the wall of the
container.
Do not operate the appliance with an empty
container while vacuum cleaning with the use
of the water filter module.
4
Cover the container with the filtration unit.
If the partition is not inserted properly, the
safety lock will prevent covering the container
with the filtration unit.
●
Prepare the vacuum cleaner for operation according
to section B.
●
The vacuum cleaner starts at the same power level it had
been working before it was turned off. Set the desired
power value (this function is only available in vacuum
cleaners type 919.0) by pressing the power adjustment
b/-
(9)
.
Do not operate the appliance for too long
without replacing the water in the container.
WET VACUUMING AND WET CLEANING
Before using the wet cleaning function thoroughly vacuum
the surface to be cleaned.
Before operating the vacuum cleaner make sure the container
is empty and the water filter module and the filters are clean.
1
Press and hold the container lid opening button
(2)
and
lift the container lid.
2
Remove the container together with the water filter
module (filtration unit and partition) from the vacuum cleaner.
3
Remove the cleaning liquid container
(24)
by pulling it by
the handle and lifting it upwards.
4
Open the filler cap and fill the cleaning liquid container
(24)
with cleaning agent (a mixture of cleaning fluid G 500
O Tens
(30)
and cold water). Use the amounts stated on the
fluid bottle label:
–
“G 500 O Tens” manufactured by BUZIL, Germany.
●
Close the filler hole of cleaning liquid container with the cap.
E
F
Содержание ZVC752 SERIES
Страница 32: ...36 ZVC752 004_v01 Zelmer Zelmer 8 230 V 16 A RU...
Страница 37: ...41 ZVC752 004_v01 11 I 1 O 2 II 1 2 G H II 32 12 919 0 8 1 2 5 8...
Страница 38: ...42 ZVC752 004_v01 EPA o 30 6 1 2 EPA 3 4 K PE I...
Страница 39: ...43 ZVC752 004_v01 Zelmer Zelmer 8 230 V 16 A BG...
Страница 44: ...48 ZVC752 004_v01 5 8 11 1 2 G 8 32 12 919 0 8 1 2...
Страница 45: ...49 ZVC752 004_v01 1 2 EPA EPA 30 6 1 2 EPA 3 4 EPA H I...
Страница 46: ...50 ZVC752 004_v01 Zelmer Zelmer 8 230 V 16 A UA...
Страница 51: ...55 ZVC752 004_v01 i 12 919 0 8 1 2 5 8 11 i a 1 2 click 1 i 2 EPA EPA 30 6 1 2 EPA 3 4 EPA G H I...
Страница 52: ...56 ZVC752 004_v01 26663 19848 5 40 1 15150 c...