26
PG-006_v01
Make sure that the power cable does not touch
the hot burners when using the hob.
The earthing wire must be connected to the
terminal marked with the symbol
. The
electrical installation supplying the hob should
be protected with a properly selected safety
device and, in addition, it should be equipped
with a suitable switch enabling the current to
be cut off in an emergency situation.
WIRING DIAGRAM
yellow-green
brown
blue
Make sure that the mains voltage corresponds to the
●
voltage on the rating label located on the appliance
casing.
The earthing wire (green and yellow in colour) must be at
●
least 20 mm longer than the phase and neutral wire.
The hob is designed to be connected to a 230 V 50 Hz AC
●
electricity supply and should be connected to a mains socket
equipped with a properly connected earthing contact.
If the electrical installation is damaged, connecting the
●
hob to the socket without an earthing contact will create
the risk of electric shock.
The installer is obliged to
fi
ll in the warranty
card, which is the basis for warranty claims.
Changing the nozzles for diff erent
type of gas
(Fig. B)
Nozzles can be changed only by a certi
fi
ed
installation technician.
The gas hob is equipped with nozzles adapted for use with
2E (G20) gas.
Type of gas, its pressure, thermal power and designation for
particular burners are shown in the tables below:
Gas hob ZPG6214XZ, ZPG6134SZ, ZPG6145XZ,
ZPG6155SZ
BURNER
GAS
PRESSURE
NOZZLE
DESIGNATION
THERMAL
POWER
SMALL
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,72
0,5
1000 W
1000 W
MEDIUM
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,98
0,65
2000 W
1700 W
LARGE
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1,23
0,8
3000 W
2500 W
WOK
2E (G20)
3B/P (G30)
20 mbar
37 mbar
4
×
0,72; 1
×
0,81
5
×
0,5
4500 W
4500 W
Gas hob ZPG6165XZ, ZPG6175SZ, ZPG6185XZ,
ZPG6194XZ, ZPG6204SZ
BURNER
GAS
PRESSURE
NOZZLE
DESIGNATION
THERMAL
POWER
SMALL
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,72
0,5
1000 W
1000 W
MEDIUM
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0,97
0,65
1750 W
1750 W
LARGE
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1,15
0,85
3000 W
3000 W
WOK
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1,35
0,98
3800 W
3800 W
1
Remove the burner cap and crown.
2
Unscrew the nozzle using a special spanner.
3
Replace the nozzle with that for a new type of gas
according to the table.
After changing the nozzles, adjust the burners (see
“FLAME ADJUSTMENT”).
After changing the nozzles af
fi
x an appropriate
label showing the new type of gas at the hob
connecting pipe.
Technical Parameters
The technical parameters are indicated on the rating label.
The hob is equipped with a threaded connecting pipe
G1/2’’ used for connecting to the gas mains. In the case of
connecting the hob to liquid gas (propane-butane) tanks the
fi
tting for
∅
8 x 1 mm hose must
fi
rst be screwed onto the
connecting pipe.
The gas hob is a class 1 appliance equipped with a power
cord with an earthing wire. It must be connected to the mains
socket equipped with an earthed pin.
The appliance satis
fi
es the requirements of relevant
standards.
The appliance complies with the following directives:
Appliances burning gaseous fuels (GAD) – 90/396/EEC,
–
93/68/EEC.
Low Voltage Directive (LVD) – 2006/95/EC.
–
Electromagnetic Compatibility (EMC) – 2004/108/EC.
–
The product is marked with the CE symbol on the rating
label.
Содержание ZPG6134SZ
Страница 2: ...D B C 2 PG 006_v01 5 5 4 1 3 3 2 2 6 2 A PL 8 7 9 10 11 ...
Страница 9: ...D B C 9 PG 006_v01 5 5 4 1 3 3 2 2 6 2 A CZ 8 7 9 10 11 proudění vzduchu těsnění ...
Страница 16: ...D B C 16 PG 006_v01 5 5 4 1 3 3 2 2 6 2 A SK 8 7 9 10 11 prúdenie vzduchu tesnenie ...
Страница 23: ...D B C 23 PG 006_v01 5 5 4 1 3 3 2 2 6 2 A EN 8 7 9 10 11 airflow seal ...
Страница 30: ...PG 006_v01 ...
Страница 31: ...PG 006_v01 ...
Страница 32: ...PG 006_v01 ...