10
DISASSEMBLY OF THE VACCUM CLEANER, TYPE VC1002.0EK
Before starting to work, carefully review the content of this Service Manual and Operation Manual
of the product.
This device is to be serviced only by properly qualified service personnel. Before you
begin remove the power plug from the outlet.
Disassembly shall be made on a table covered with a clean felt or other soft material, so as not to scratch
the parts.
- remove the plate for outlet air
13
with the outlet filter
12
- release the hinges and pull out front cover assembly
27
(see pictures number 1 and 2)
Picture no. 1
Picture no. 2
- remove the on/off button
1
by lifting it up with a flat-blade screwdriver
- remove the four screws
101
, lift the back cover up and disconnect the wires from the switch
28
and potentiom-
eter
6
, remove the two screws
100
securing the cover do potentiometer
7
, remove it
- remove the cord rewind button
4
by lifting it up with a flat-blade screwdriver
- release the latches and remove the lock for dust bag
19
- remove the suction mouth
17
with a two flat-blade screwdriver, remove the seal for suction mouth
16
(see pic-
ture number 2)
Picture no. 2
- lift up the motor
25
, disconnect the lead wire connectors
- remove the two screws
102
securing the control PCB
22
disconnect the lead wire connectors
- lift up the cord rewind assy
23
, disconnect the lead wire connectors
- lift up the inlet filter
20
- remove the back wheel
11
with a flat-blade screwdriver
- remove the small wheel
14
with a flat-blade screwdriver