29
526-001_v01
Features
ZELMER cooker hood is used to extract cooking fumes.
It requires to install a duct extracting air to the outside. The
length of the duct (most commonly a tube Ø 120 mm) should
not exceed 4-5 m.
After installing the active-coal filter which is available in the
sales network, the cooker may operate as an odor absorber.
In this case it is not required to install the duct extracting the
air to the outside, however it is recommended to install an
air exhaust fin.
The cooker hood is a class II electrical appliance.
It is equipped with an independent lighting and an extract fan
with three speed settings.
The cooker hood is designed for a permanent installation on
a vertical wall above the gas or electric cooker.
Parts
(Fig. A)
The cooker hood is composed of the following elements:
1
The hood body equipped with the lighting and fan unit.
2
A fabric filter
3
A ring enabling to fix to the ventilation grill
4
Lacquered net protecting the fabric filter.
Assembly
In order to assemble the cooker hood:
1
Install the cooker hood at an appropriate height (at least
650 mm from the electric cooking plate and at least 700 mm
from a gas cooker).
2
Plug in the appliance.
Installing the cooker hood (Fig. B)
1
Mark a vertical line on the wall indicating the center of
the kitchen plate.
2
Dismantle the net protecting the fabric filter.
3
Put the cooker hood housing against the wall with
the marked center on the vertical middle line, keeping the
minimal distance of 650 mm from the surface of the kitchen.
Make sure the housing is leveled.
4
Mark the position of the assembly holes on the wall.
5
Drill the holes marked on the wall using a drill with the
diameter corresponding to the enclosed rawlplugs, insert the
rawlplugs in the holes and fix the cooker hood housing to the
wall.
6
Install the net protecting the fabric filter.
Plug in and operation control
After plugging the appliance in (according to the previously
described requirements), check if the cooker hood lighting
works and if its motor operates correctly.
After installing the cooker hood, the socket should be easily
accessible in order to unplug the appliance.
Setting the operation mode
Setting the extraction operation mode
During the extraction mode, air is extracted to the outside
with a special duct. Remove the coal filters with this setting.
The cooker hood is connected to an opening that extracts
the air to the outside with a stiff or flexible duct with the
diameter of 120 mm and appropriate duct clamps which are
to be purchased in installation materials supply stores. The
installation should be performed by a qualified fitter.
Setting the odor absorber operation mode
While using this mode, filtered air comes back to the room
through openings on both sides of the upper chimney. While
using this mode, the coal filter should be installed, it is also
recommended to install an air exhaust fin
(Fig. C)
.
The speed of the fan
The lowest and medium speed settings are used in normal
conditions and low cooking fume intensity. The highest
speed setting should be used only in case of an intense level
of cooking fumes e.g. during frying or grilling.
Operation
Control panel (Fig. D)
The cooker hood can be controlled using an integrated
switch.
0 – motor off,
1 – first operation speed,
2 – second operation speed,
3 – third operation speed,
– light on/off.
This adjustment allows to set the optimal fan speed for the
user’s needs with a minimal noise level.
Cleaning and maintenance
(Fig. E)
Maintenance
Regular cleaning and maintenance will guarantee a good
and failure-free operation of the cooker hood and will prolong
its useful life. Make sure the aluminum filters and the active-
coal filters are replaced according to the manufacturer’s
recommendations.
Anti-grease aluminum filters
Cleaning
Anti-grease filters should be replaced every three months.
The applied fabric filters cannot be cleaned.
Replacement
To dismantle the filters:
removing the lower cover by releasing the catch,
●
taking out the fabric anti-grease filter.
●
Содержание 26.50
Страница 2: ...2 526 001_v01 A B C D E 1 2 4 4...
Страница 18: ...18 526 001_v01 Zelmer Zelmer 650 700 2 RU 0 004 4 8 8...
Страница 20: ...20 526 001_v01 120 C O 0 1 2 3 E K A 3 O 40 W...
Страница 21: ...21 526 001_v01 K PE...
Страница 23: ...23 526 001_v01 LVD 2006 95 EC EMC 2004 108 EC CE ZELMER 120 4 5 A 1 2 3 4 1 650 700 2 B 1 2 3 650 4 5 6 120 C...
Страница 24: ...24 526 001_v01 D 0 1 2 3 E 3 40 W...
Страница 27: ...27 526 001_v01 E i i 3 40 W 26663 19848 5 40 1 15150...
Страница 31: ...526 001_v01...
Страница 32: ...526 001_v01...