background image

20

HD1600V2 User Guide, Version 1.4, 10/30/13

Using The HD1600V2

EDID

EDID is simple in concept. Each monitor or receiver contains a small data block that indicates what the 
monitor’s or receiver’s capabilities are. When a source connects to a monitor, the monitor’s EDID is 
read, and using this information, the source adjusts its output to match the capabilities of the monitor. 
If a monitor can display 1080p and the source can output 1080p, then 1080p will be used. The same is 
true for audio formats. The EDID will contain multiple resolutions that the monitor can display, and if 
it can decode multiple audio formats, these formats will also be included in the EDID. The source will 
compare the capabilities of the monitor, and it’s own capabilities, and choose the best video and audio 
solution to send over the HDMI link.

This works well when a single source is connected to a single monitor. A matrix switch complicates 
this a bit. What happens when two monitors are connected to the same source? Which EDID is used to 
indicate what the monitors are capable of displaying? What if the monitors have different capabilities?

Traditionally this has been handle in a number of different ways. Some switches will use predefined 
EDIDs that forces certain modes, like 1080p, 1080i or 720p and Dolby5.1 or PCM stereo audio, and 
then assume all monitors can handle this.

Other solutions involve reading a single monitor's EDID and sending it all sources. Or a pass through 
mode, where and single EDID is sent to a single source (in some switches this will prevent the viewing 
of this source by any other zones).

There have been solutions that depend upon the order of switching, where the 1st zone to switch to a 
source determines the EDID that is used. This is ideal if only one zone is switched to a source at a time. 
A shared source can have a different EDIDs, depending upon switching order. This can lead to confu-
sion 

“Why does Dolby5.1 only work sometimes?”,

 and requires the user to disconnect all zones from a 

source and reconnect them in a different order, depending upon what EDID features they want. This 
can be disruptive to all viewers of a source, as well as hard to explain to the end user why this is neces-
sary. Or alternatively it requires custom driver programming at each install.

Our solution is to allow any combination of EDIDs to be combined and sent to any source. This allows 
the flexibility of setting a source EDID to the capabilities of any single monitor / receiver, or any com-
bination of monitors / receivers. Each source can be sent a different combination of zone EDIDs. The 
EDIDs sent to the source, are not switching order dependent, and since the EDIDs are based on zone 
EDIDs, they are always valid.

By default, all the EDIDs of all zones (monitors and receivers) are read, and the lowest common fea-
tures of all the zones are combined into a single EDID, that is sent to all the sources. For instance, if all 
the zones can receive Dolby5.1 audio, then the EDID will indicate that Dolby5.1 can be sent. If how-
ever even a single TV can only decode PCM stereo, the combined EDID will indicate to the all the 
sources that only PCM stereo can be sent to any zone.

You can now use the 

ESet

 screen to combine the EDIDs of similar devices and send the combined 

EDID to a source that will be associated with the devices. For instance all receivers can be combined 
and sent to a Blu-ray or Cable box that will be used mostly for those receivers. This allows you to 
enable Dolby5.1, or Dolby TrueHD, or any other features the receivers are capable of decoding.

Here are some common examples:

Scenario 1

You have a dedicated Blu-ray player to be used by a single hometheater receiver. You would use the 

ESet

 screen to set the EDID of the Blu-ray’s source to include only the zone of the hometheater 

receiver. In this case, the EDID of the hometheater will be sent directly to the Blu-ray player and all 
audio modes of the hometheater receiver will be available to the Blu-ray player. This will not prevent 
any other zones from switching to the Blu-ray player, but there can be issues if another zone does not 
support the same audio formats that the hometheater does. Leave all the other EDIDs to their default 
values, and all other sources will be viewable by all zones.

Содержание HD1600-V2

Страница 1: ...HDMI Matrix Switches HD1600 V2 User Guide...

Страница 2: ......

Страница 3: ...ss plugged into a UL rated battery backup and or surge protection device 13 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such...

Страница 4: ...I description Added definitions for the EDLO and KSIZI commands Spelling corrections Version 1 2 09 11 2013 Added EDID description Added the ESet menu option Added the ESET serial command Fixed the KS...

Страница 5: ...The Error Response 26 The Query Response 26 Using Bitmapped Parameters 27 Reading Writing Bitmapped Parameters 27 Reference for Basic Control Commands 28 Definitions 28 Zone 28 Input 28 Channel 28 Ba...

Страница 6: ...6 HD1600 Serial Protocol Version 1 4 10 30 13 EDLO EDID Lock 44 ESET Assign zones to an input source 44 KSIZI Set the number of HDCP keys of a source 45...

Страница 7: ...ork is needed we request that you hold on to the original packaging materials Please take this time to verify the contents of the HD1600V2 box The following should be included HD1600V2 HDMI Matrix Swi...

Страница 8: ...depending upon the screen selected For instance when one of the source zone switching display is being used these buttons will allow switching between the sources BACK and NEXT Screen dependent button...

Страница 9: ...also sent over the Cat5 6 cable and the HDBaseT receiver does not need a separate power supply Local Out These are local HDMI outputs They are not mirrored outputs plugging in an HDMI monitor to one...

Страница 10: ...to it These are 100Mbs full duplex channels There are no internal connections between the outputs to send the Ethernet down all 8 zones you will need some type of 8 port Ethernet switch SPDIF Inputs...

Страница 11: ...off Through out the manual the above sequence would be shortened to Setup Off Pressing the SELECT knob performs two functions The first is to select a menu option as shown by the OFF example given abo...

Страница 12: ...x output To change the HDMI mappings Use the SELECT knob to select the Map HDMI Input Output option HdmiSw To change the HDMI mappings with audio video breakaway While in the HdmiSw screen press the B...

Страница 13: ...ven zone to the new source and the mode will change back to the selection mode Zone A represents the ALL zone Setting zone A to a source will set all the zones to the given source Setting a source to...

Страница 14: ...llowing you to change the static IP address the IP mask and the IP gateway parameters To change any of the parameters select the parameter you want to change address mask or gate way and press the SEL...

Страница 15: ...te the source to each monitor Since there are more monitors than keys this must be done using smaller groups of keys If the source is capable of issuing 3 keys then the switch will authenticate 3 moni...

Страница 16: ...menu press the MENU button Use the SELECT knob to select the Assign EDID zones option Setup ESet Use the ZONE buttons to switch between sources Use the SELECT knob to scroll to a zone and the press th...

Страница 17: ...ID settings should be locked Once locked all EDID settings will be ignored and displays will not flicker when an A V receiver is powered cycled Note When the EDID settings are locked any EDID changes...

Страница 18: ...rrently read into cache All HDCP keys currently read into cache The HDCP count settings The EDID lock setting To save the EDID HDCP settings If the LCD display is not at showing the main menu press th...

Страница 19: ...allows the source DVD player Cable Box etc to determine the number of simultaneous monitors allowed to view it s content Some cable box manufacturers only supplied a single HDCP key while some Blu ray...

Страница 20: ...different order depending upon what EDID features they want This can be disruptive to all viewers of a source as well as hard to explain to the end user why this is neces sary Or alternatively it req...

Страница 21: ...to view and listen to anything played on the Blu ray player Other zones may or may not be able to depending upon their capabilities Scenario 3 You have two 3D displays and one Blu ray player dedicate...

Страница 22: ...ge verify that a picture can be seen on all zones There can be a lot of video blanking and flickering at this point and if you have sources that have manual HDCP key count settings this could take a w...

Страница 23: ...aneously each port s commands will be buffered until the ending is read at which time the commands will be executed in the order received All responses will be sent to both Serial ports and TCP IP con...

Страница 24: ...th USB to RS 232 conversion cables these are all typically straight through cables Be sure to install any drivers that come with the USB to RS 232 cable you are using The RS 232 port is a female type...

Страница 25: ...ommand P 0 Response from the A V switch for new setting NOTE Only the characters between and are valid any characters sent before the or after the will be ignored NOTE By default the HD1600V2 adds a c...

Страница 26: ...ensitive and in the HD1600V2 all commands are upper case Error 2 One of the parameters given was too large or too small the command will be ignored Error 3 Something was wrong with the command s synta...

Страница 27: ...t the bits ASY and IRS to be set to 1 and the rest of the bits set to zero the parameter s value would be calculated as 1 1024 making the parameter value 1025 The command to set those two bits to ones...

Страница 28: ...outputs known as zones A single zone consists of the combination of a HDMI video channel and an HDMI audio channel For most commands zones are indicated by using a prefix character Input An input or s...

Страница 29: ...P 2 and P 3 commands By issuing a P 3 command lock power on the HD1600V2 will be turned on and locked Only a subsequent P 2 command will turn off the HD1600V2 The P 0 and P 1 commands will be ignored...

Страница 30: ...sponse string is sent per zone Or in the case of channel breakaways only one response string per channel is returned The response string is sent as a fixed length string using leading zeroes You can r...

Страница 31: ...together the above numbers you can switch any combination of channels without affecting the unselected channels For instance HSZ 1 3 4 would map only the HDMI video from input 4 to zone 3 To map both...

Страница 32: ...can have the HD1600V2 always send the channel with the response string This keeps you from having to parse two different types of strings Using the XS command to set the CHN bit will cause the HD1600...

Страница 33: ...Muted ch Channel bitmap Range 1 3 MZ Examples The MZ command in its simplest form MZ 1 3 1 mutes all channels of the zones 1 and 3 You can also mute unmute multiple zones using a single command For in...

Страница 34: ...isconnect a zone from any source When audio is muted the sound is turned off When video is muted video is turned off leaving a black screen Or possibly blue screen depending upon how your receiver act...

Страница 35: ...is would mute the HDMI video and HDMI audio channels on zones 2 and 3 HMZ Query Examples There are two forms of the query response string depending upon whether any channel breakaway options are in af...

Страница 36: ...1600V2 always send the channel with the response string This keeps you from having to parse two different types of strings HMZ Query Examples Using the XS command to set the CHN bit will cause the HD1...

Страница 37: ...The format of the command is XS settings1 settings2 Set the control bits to settings1 and settings2 XS settings1 settings2 Set bits indicated in settings1 and settings2 to 1 XS settings1 settings2 Res...

Страница 38: ...is only sent when requested ACK Enable Disable Acknowledgements Each time a command is sent to the HD1600V2 the HD1600V2 responds with either an error mes sage if there was a problem with the command...

Страница 39: ...This command uses a bitmapped parameter to indicate which values are to be saved A bit set to 1 indicates the associated setting should be saved a bit set to 0 indicates the setting should not be save...

Страница 40: ...page 27 for more information on using bitmapped parame ters Allows changing the behavior of the front panel LEDs and adjusting their intensities LI mode dim bright off Set mode and intensities LI Que...

Страница 41: ...c mode the IP address IP mask and gateway address given by the IPA IPM and IPG commands will be used You can easily switch between the two modes without losing the static address setting In other word...

Страница 42: ...y change the TCP IP mask It sets up the static mask that will be used the next time the IPSET 0 command is issued The command format is IPM xxx xxx xxx xxx Set new TCP IP mask IPM Read the current TCP...

Страница 43: ...x xxx IP address in standard form Ex 192 168 001 200 IPMX Retrieve the current IP mask in use This command is read only and will return the IP mask being used by the HD1600V2 If DHCP is being used thi...

Страница 44: ...tion of the HD1600V2 on page 22 Once your system is validated you should lock the EDID and then save the new HDMI settings in EEPROM so that they won t be lost when power is cycled See SS Save Default...

Страница 45: ...e monitor can negotiate an HDCP connection with the source When a second monitor is switch to the source it will be unable to connect In most cases this will also break the video connection to the wor...

Страница 46: ...ailable in source 0 Key limits are not checked 1 23 Limit the num ber of HDCP keys to n This setting is lost when power is cycled on the HD1600V2 To save this settings through a power cycle backup the...

Отзывы: