39
4 Advanced settings for
the IR Prog room thermostat
Turn the dial to
NO HEAT
and press the
rightmost button for 5 seconds until the
screen displays H600 x:xx (remote control
model number).
Press
OK
. The screen will display CF01.
4.1 Adjusting the room temperature
measurement (CF01)
If the room temperature measured by the
thermostat deviates from actual room
temperature, the thermostat measurement
can be adjusted by up to +/- 4°C by pressing
the
+
and
-
buttons.
Press
+
or
-
to select the desired value then
press
OK
to confirm and move to the next
menu.
4.2 Selecting the temperature
displayed in Auto mode (CF02)
Using this function you can choose to
display either the room temperature
measured by your thermostat or the
setpoint temperature. Press
+
or
-
to select
the desired value then press
OK
to confirm
and move to the next menu.
0
: room temperature always
displayed
1
: setpoint temperature always
displayed
5 sec
E N
3.4.3 manual mode
Pressing the button will cause the
appliance to heat continuously for an
adjustable period of between 30 minutes
and 4 hours (boost).
When in automatic mode (
AUTO
), press the
button.
The manual mode duration will blink. Press
+
or
-
to increase or decrease the desired
duration in 30 minute increments. Press
OK
to confirm.
The time remaining will scroll across the
display. Press the
C
button to exit manual
mode at any time.
3.5 No Heat mode
To put the radiator into No Heat mode
(in summer, for example), turn the dial
to . The thermostat will display the
measured room temperature.
Manual mode active
Room temperature
38
E N