Страница 1: ...pumps Booster units Pompe de jardin Usine hydraulique de maison Baureihe Series S rie WX HWX Betriebsanleitung Operating Instructions Manuel d utilisation GB D WX 3200 HWX 3200 WX 3800 HWX 3800 HWX E...

Страница 2: ...EG Niederspannungsrichtlinie 93 68 EWG Anhang I im Sinne der EMV Richtlinie 92 31 EWG und 93 68 EWG im Sinne der Maschinenrichtlinie 2006 42 EG Hiermit erkl ren wir die ZEHNDER Pumpen GmbH Zw nitzer S...

Страница 3: ...00 HWX 3800 HWX E 3800 WX 5200 HWX 5200 HWX E 5200 Stand der Betriebsanleitung August 2008 1 2 Anfragen und Bestellungen Anfragen und Bestellungen richten Sie bitte an Ihren Fach bzw Einzelhandel 1 3...

Страница 4: ...t dieses zu schulen und zu unterweisen Dies kann falls erforderlich im Auftrag des Betreibers der Pumpen durch den Hersteller Lieferant erfolgen Weiterhin ist durch den Betreiber sicherzustellen dass...

Страница 5: ...u kabels mit 230 V 50 Hz Wechselstrom Die Pumpe muss an eine Steckdose mit Erdung angeschlossen werden Pumpe nicht am Kabel ziehen oder tragen Die Pumpe darf mit einem besch digten Kabel nicht in Betr...

Страница 6: ...maler F rderh he der Pumpe laut Typenschild minus Ansaugh he Der Ausschaltdruck sollte mindestens 5 m 0 5 bar unter dem maximal erreichbaren Druck der Pumpe liegen Nach dem Ver ndern des Einschaltdruc...

Страница 7: ...abdichten Schnellkupplungen z B Geka mit Nachstellring zum Anpressen verwenden Saugh he zu gro max 8 5 m Saugh he verringern Saugschlauch zieht sich zusammen Spiralsaugschlauch verwenden aktivierter...

Страница 8: ...cksendungen an den Hersteller bitte nur frei und in der Originalverpackung an Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Zur Verk rzung der Reparaturzeit benennen Sie uns bitte...

Страница 9: ...aration of Conformity In accordance with EEC low voltage specifications 93 68 EWG app I In accordance with EMV Specifications 92 31 EWG und 93 68 EWG In accordance with 2006 42 EG We the following ZEH...

Страница 10: ...horised retail trader 1 3 Technical data Typ WX 3200 HWX 3200 WX 3800 HWX 3800 HWX E 3800 WX 5200 HWX 5200 HWX E 5200 Power P1 600 Watt 1000 Watt 1600 Watt Power P2 350 Watt 700 Watt 1300 Watt Voltage...

Страница 11: ...to non compliance with safety advice Ignoring of safety instructions can lead to danger of personnel and to the environment as well as causing possible damage to the equipment Non compliance with saf...

Страница 12: ...al protection this circuit breaker must trip out when earth fault current exceeds 30mA The pump must not drop in water and also not submersible Any operation of the pump next to a swimming pool or gar...

Страница 13: ...e diaphragm vessel The air pressure must be approx 0 2 to 0 3 bar less than starting pressure of the unit Procedure Disconnect the power supply Open the tap that the system will be vented Remove the b...

Страница 14: ...n short intervals Diaphragm in vessel damaged Leakiness at the air valve Renew the diaphragm expendable part To less pre pressure in diaphragm vessel Produce the necessary air pressure see ch 4 Pressu...

Страница 15: ...nformit Dans le sens de la directive de basse tension EG 93 68 EWG annexe I Dans le sens la directive EMV 92 31 EWG et 93 68 EWG Dans le sens la directive 2006 42 EG Nous d clarons nous ZEHNDER Pompes...

Страница 16: ...X 3200 HWX 3200 WX 3800 HWX 3800 HWX E 3800 WX 5200 HWX 5200 HWX E 5200 Etat du manuel d utilisation Ao t 2008 1 2 Demandes et commandes Veuillez adresser vos demandes et commandes votre commer ant de...

Страница 17: ...teur une formation s il ne poss de pas ces connaissances n cessaires Une telle formation peut avoir lieu au besoin sur ordre de l op rateur des pompes par le fabricant fournisseur L op rateur doit enc...

Страница 18: ...e long avec 030 v 50 Hz de c urant alternati La pompe doi4 tre attach e une prise avec une mise terre Si l alimentation en courant ne devait pas s effectuer oblig toirement par u Interrupteur de prote...

Страница 19: ...p t Parce que la modification d un point de distribution peut influencer l autre point de distribution il faut contr ler dans tous les cas la pression de d clenchement On Off ATTENTION La pression de...

Страница 20: ...nt exclues Les d rangements qui ne peuvent pas tre facilement r par s ne devraient tre limin s que par le service clients de Zender ou par des entreprises sp cialis es autoris es Les dommages qui sont...

Страница 21: ...viron 2 bar voir point 4 Valve de pied perm able et ou pas existante Nettoyez resp installez la valve de pied Interrupteur pression en panne Renouvelez l interrupteur pression 4 La pompe ne d clenche...

Страница 22: ...dichtung kompl Mechanical seal Garniture tanche anneau glissant compl 16a 1 Geh usedichtung O ring 160x3 Joint de carter 17 7 8 Zylinderschraube M6x20 Screw M6x20 Vis de cylindre M6x20 20 1 3 Stopfen...

Страница 23: ...23 Ersatzteilzeichnung Spare parts drawing Dessin des pi ces de rechange...