Using your appliance
49
10/2017
EN
48
40016514
NOTE:
You can always use your blower while P3 is running.
Press
P1
or
P2
to activate programmes P1 and/or P2.
Press
BOOST
to run a manual boost.
At the end of the manual boost or programmes P1 and/or P2, programme P3
continues to operate normally.
4.5.2 Setting programme P3
For each hour of each day you can decide to set your radiator to ECO or
COMFORT mode.
A long press on
P2
and
BOOST
opens the settings
for the weekly programme P3.
The days of the week are displayed on the left of the
screen, and the hours of the day displayed at the bottom. The
left-hand and bottom cursors point to the day and the time while
setting the programme.
The screen displays the starting date D1 for 3 seconds.
The screen displays the start time 00:00. The symbol, PROG,
and the first hour of the day flashes.
Pressing the
+
button sets the chosen hour to
COM-
FOrT
mode and goes to the next hour.
Pressing the
-
button sets the chosen hour to
ECO
mode
and goes to the next hour.
Scrolling through the hours of a day continues as long as
you have not changed the day.
After setting the final hour, you will automatically go to
the next day (the screen displays the number of the day for
3 seconds).
A brief press on the
P2
button moves the programme on
to the next day, it is set at 00:00.
A brief press on the
P1
button moves the programme
back to the previous day and is set at 00:00.
The screen displays the number of the day for 3 seconds.
Pressing and holding the
P2
button moves the programme on to the next day,
copying the current day’s programme, with the cursor set at 00:00.
Pressing and holding the
P1
button moves the
programme back to the previous day, copying the current day’s
programme, with the cursor set at 00:00.
The screen displays the number of the day for 3 seconds.
A
B
A short press on button
P2
lets you quit the programming once day 7 is reached.
4.6 Pilot wire mode
Your towel drier can be controlled remotely from a pilot wire programming unit
(not supplied with your device).
The modes transmitted by the control unit are STOP HEATING, FROST-FREE,
ECO, COMFORT, COMFORT -1°C and COMFORT -2°C.
Use your remote control to set the desired temperature
(
see section 4.3
).
Press
P2
and
+
to activate the pilot wire mode.
Icon A
is displayed on the remote control screen.
Press
P2
and
+
again to disable the pilot wire mode.
Icon A
disappears from the screen.
The default display selected in the advanced parameters
(time or temperature) remains active while the control unit
controls your device.
Then refer to the manual of your programming control unit for further information
on the use of your radiator with it.
The programming control unit only runs the electric towel-radiator and not
the blower.
NOTE:
A manual boost can always be run during pilot wire mode operation.
Conversely, it is impossible to run a P1, P2 or P3 programme.
NOTE:
Any change to the operating mode required by the programming unit closes
the effects of a window open detection (
see chapter 4.7
).
Control unit
order
Mode
Comfort
Steady green Steady green
Steady green
Eco
Steady green
Off
Flashing green
(slow)
Frost
protection
Steady green
Off
Flashing green
(fast)
Stop
Steady green
Off
Off
C