EN- 7
4.1 Configuration unit
Position
Part
A
External casing of coated sheetsteel
B
Interior of high-quality, expanded polypropylene EPP and ABS
C
5 connections for the air ducts
D
2 filters for air purification
E
2 energy-efficient DC motors with high-efficient fan
F
HE (High efficient) heat exchanger or enthalpy exchanger (standard in unit version “Enthalpie” and “ERV”)
G
Display to read data, and for programming procedures (not present in the unit version “Luxe”)
H
Electronics box with the Control PCB of the unit for all the standard connections
I
Identification plate detailing information on the unit (not visible)
J
Condensation drain to drain the condensation of the warm return air
K
Sticker detailing the air connections (not visible)
L
2 Service connectors for the ComfoSense or PC
The service connectors cannot be used at the same time
M
4 Filter caps
N
Pre heater (standard in unit version “V” and “PH”)