- Use for cooking, showering and if 

 

 

   extra ventilation is required. 

The ComfoControl will display " 

 " as stand-

ard during manual ventilation, and not " 

 ".  

If you wish to reactivate the automatic ventilation setting, 
then: 
•  Press  "AUTO"  to  return  to  the  automatic  ventilation 

setting. 

2.2.4   Switching extractor hood on/off 

The procedure is as follows:  
1. 

Press

 " 

 " to activate the extractor hood. 

2. 

Press

 " " or " " to set the ventilation volume for the 

extractor hood. 

3. 

Press

 " 

 " to confi rm the settings and return to the 

main screen. 

  The  extractor  hood  symbol  ("

")  then  appears 

on the ComfoControl display. 

4.  

Press

  " 

  "  again  to  deactivate  the  extractor 

hood. 

Note!

If the extractor hood is fi tted with a time-delay switch (see 
§ 2.2.8 for more information about time delay), then it will 
not switch off immediately, but will continue to run for the 
programmed time period. 

  The extractor hood symbol (“

”) disappears from 

the ComfoControl display once the programmed 
time delay has run its course. 

Note! 

If the extractor hood is fi tted with a time-delay switch (see 
§  2.2.8  for  more  information  about  time  delay),  then  the 
time  delay  symbol  (“

”)  will  appear  on  the  ComfoCon-

trol display in place of the ventilation volume buttons. The 
extractor hood will be switched off after the programmed 
number of minutes.  

There 

is 

no 

ventilation 

volume 

setting 

(“ 

  “)  displayed  on  the  ComfoControl  is  when  the 

extractor  hood  is  activated.  Instead,  the  extractor  hood 
ventilation setting is displayed in the extractor hood sym-
bol. These are: 

•  “

” for extractor hood ventilation setting 1. 

•  “

” for extractor hood ventilation setting 2. 

•  “

” for extractor hood ventilation setting 3. 

If the extractor hood is running, the programmed 
ventilation  setting  is  displayed  in  the  extractor 
hood symbol (e.g. “

”). 

2.2.5   Switching the supply and exhaust fan on/off 

The procedure is as follows:  
1. 

Press

 “ 

 « to switch off the supply fan. 

2. 

Press

 “ 

 « to switch off the exhaust fan.

  Once the supply and exhaust fans have been de-

activated, “

” is displayed on the ComfoControl 

to indicate they are switched off. 

3. 

Press

 “

” by the supply fan symbol to reactivate the 

supply fan. 

4. 

Press

  “

”  by  the  exhaust  fan  symbol  to  reactivate 

the exhaust fan. 

  Once  the  supply  and  exhaust  fans  have  been 

activated,  both  “ ”  and  “ ”  are  displayed  on 
the  ComfoControl  to  indicate  they  have  been 
switched on again. 

English

Содержание ComfoControl Luxe

Страница 1: ...ComfoControl Luxe Handleiding Manual Manuel Anleitung comfosystems...

Страница 2: ...ramme settings 5 2 2 7 Temperature programme settings 6 2 2 8 Time delay settings 7 2 2 9 Temperature correction settings 7 2 2 10 Screen settings 8 2 2 11 Language settings 8 2 3 System data 9 2 3 1...

Страница 3: ...ed by the manu facturer unauthorised alterations and or modifications have been made to the unit 1 2 3 Liability The ComfoControl has been designed and produced for use in ventilation and cooling syst...

Страница 4: ...automatically Your settings have now been saved 2 1 ComfoControl The ComfoControl regulates your ventilation and or cooling system The ComfoControl is mounted to the living room wall and communicates...

Страница 5: ...the sum mer the active cooling can be activated while this is not desirable under normal winter conditions All the same if you wish to use active cooling in the winter then set the temperature to COOL...

Страница 6: ...nformation about time delay then the time delay symbol will appear on the ComfoCon trol display in place of the ventilation volume buttons The extractor hood will be switched off after the programmed...

Страница 7: ...et as follows 1 Press 2 Press 3 Setting the ventilation programme Select day Mo Tu We Th Fr Sa or Su Select hour 00 00 to 23 00 using or If required press the hour for example and then select the minu...

Страница 8: ...e temperature settings can be changed set as follows 1 Press 2 Press 3 Setting the temperature programme Select day Mo Tu We Th Fr Sa or Su Select hour 00 00 to 23 00 using or If required press the ho...

Страница 9: ...Time delay settings Use the ComfoControl to Programme a time delay for certain ventilation set tings The procedure is as follows 1 Press 2 Press 3 Press 4 Press or to choose between Time delay for th...

Страница 10: ...njunction with a heating system thermostat we recommended synchronizing the temperature for both units on the display Use the ComfoControl to Programme a temperature correction relative to the re cord...

Страница 11: ...of a malfunction the ComfoControl will dis play the corresponding code The ComfoControl display will show an A or an E fol lowed by a number What to do in the event of a malfunction In the event of a...

Страница 12: ...g the materials in an environmentally friendly manner 3 For the Fitter This chapter describes how to fit the ComfoControl 3 1 Installation conditions In order to determine whether the ComfoControl can...

Страница 13: ...Jumpers Right Relay 2 Open Comm Power Relay Relay Temp Sens Therm RS 485 12V DC 1 2 A B The temperature sensor specification is NTC 10 K optional The external temperature sensor is optional The indoor...

Страница 14: ...nnected the OK will not appear on the screen and the re lated P menus will not be available 7 Using or select the required P menu e g P5 OPTIONS 8 Press OK to confirm the P menu selected 9 Using or se...

Страница 15: ...e main menu The procedure is as follows 15 Press to return to the INSTALLATION MENU 16 Press again to return to the main screen After five minutes the ComfoControl will return automatically to the mai...

Отзывы: