background image

   1 - EN

 Preface

 Carefully read this manual before use.

This manual provides all the information required 
for safe and optimal operation of the ComfoAir 350. 
It is also intended as a reference  for servicing, so 
that this can be carried out in a responsible manner. 
The device is subject to continuous development 
and improvement. As a result, the ComfoAir 350  
may slightly differ from the descriptions.

NOTE

This manual has been compiled with  

the utmost care. However, no rights can be 

derived from it. In addition, we at all times 

reserve the right to change the contents of 

this manual, without prior notice.

1  Introduction

The device's name is ComfoAir 350 . In the follow-
ing it will be referred to as ComfoAir.
The ComfoAir is a balanced ventilation system with 
heat recovery in order to create healthy, balanced 
and energy-efficient ventilation in houses. The 
ComfoAir has a CE marking on the identification 
plate. The identification plate can be found on top 
of the ComfoAir.

1.1   Warranty and liability

1.1.1 General

The sales and warranty conditions for companies in 
the metal, plastic and technology industries, which 
apply to the ComfoAir, have been deposited with 
the Clerk of the District Courts of the Hague on 19th 
October 1998, under number 119/1998.

1.1.2   Guarantee  conditions

The ComfoAir is covered by a manufacturer’s war-
ranty for a period of 24 months after fitting up to 
a maximum of 30 months after the date of manu-
facture. Warranty claims may only be submitted for 
material faults and/or construction faults arising 
during the warranty period. In the case of a war-
ranty claim, the ComfoAir must not be dismantled 
without written permission from the manufacturer. 
Spare parts are only covered by guarantee, if they 
were supplied by the manufacturer and have been 
installed by an approved installer.

The warranty becomes invalid if:

•   The guarantee period has elapsed;

• 

The device is used without filters;

• 

Parts are used that have not been supplied by 
the manufacturer;

• 

Non-authorised changes or modifications have 
been made to the unit.

1.1.3   Liability

The ComfoAir has been designed and manufac-
tured for use in “balanced ventilation systems”. Any 
other use is deemed unintended use and can lead 
to damage to the ComfoAir or personal injury, for 
which the manufacturer cannot be held liable.
The manufacturer is not liable for any damage origi-
nating from:
•  Non-compliance with the safety, operating and 

maintenance instructions in this manual;

• 

The use of components not supplied or recom-
mended by the manufacturer.

 

Responsibility for the use of such components 
lies entirely with the installer;

• 

Normal wear and tear.

Содержание ComfoAir 350

Страница 1: ...I EN ComfoAir 350 User manual...

Страница 2: ...has been compiled with the utmost care The publisher cannot be held liable for any damage caused as a result of missing or incorrect information in this manual In case of dis putes the Dutch version...

Страница 3: ...fire programme 3 2 1 6 Wireless RF control optional 3 2 1 7 Preheater element optional 3 2 1 8 Enthalpy optional 3 2 2 Available operating devices 4 2 2 1 Display 4 2 2 2 3 position switch 4 2 2 3 Ba...

Страница 4: ...EN IV...

Страница 5: ...n 19th October 1998 under number 119 1998 1 1 2 Guarantee conditions The ComfoAir is covered by a manufacturer s war ranty for a period of 24 months after fitting up to a maximum of 30 months after th...

Страница 6: ...the ComfoAir throughout its life Instructions with regard to cleaning or replacing the filters of the intake and exhaust valves must be carefully observed The specifications stated in this document ma...

Страница 7: ...der outside air in at night the indoor temperature of the dwelling can be kept low during hot days The bypass works auto matically simply set the required comfort tempera ture 2 1 4 Frost protection T...

Страница 8: ...Activation delay 3 s P22 Select 22 4 OK 30 Current setting 5 10 x or press and hold 20 Select 20 6 OK P22 Sets the value to 20 7 MENU P2 8 MENU 1 Fan setting Only in the P2 menus settings can be made...

Страница 9: ...on level This switch is mostly fitted in the bathroom to extract any excess moisture after showering as soon as possible The bathroom switches vary widely in model and are therefore not illustrated he...

Страница 10: ...15 Min 0 Min P22 Optional Note Only applies to systems fitted with a corded switch and a second switch in the bathroom Overrun timer for the bathroom switch to switch to normal position x minutes afte...

Страница 11: ...ted with an RF switch Overrun timer for ventilation setting 3 us ing After pressing continuously 2 sec the ComfoAir will switch to the high setting for x minutes and then au tomatically returns to the...

Страница 12: ...tilation system could have become dirty with building dust 2 4 2 Cleaning the valves in your dwelling The ventilation system may be fitted with the fol lowing valves Exhaust valve STB Exhaust valve ST...

Страница 13: ...once more 2 5 3 What to do in the event of a malfunction In the event of a malfunction contact the installer Note down the malfunction code that appears on the digital operating device Make a note of...

Страница 14: ...Company register Zwolle 05022293 EEC declaration of conformity Machine description Heat recovery units ComfoAir 350 series Complies with the following directives Machinery Directive 2006 42 EEC Low V...

Страница 15: ...11 EN...

Страница 16: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Zwole Nederland Tel 038 429 69 11 Fax 038 422 56 94 Internet www jestorkair nl E mail info jestorkair nl Zehnder Group Nederland B V 849050655 0711...

Отзывы: