EN - 6
2.3 P menus for the user
Menu P1
¨
Status of programmes
status
sub-
menu
description
Activated
P11
Is menu 21 currently active?
Yes (1) / No (0)
P12
Is menu 22 currently active?
Yes (1) / No (0)
P13
Is menu 23 currently active?
Yes (1) / No (0)
P14
Is menu 24 currently active?
Yes (1) / No (0)
P15
Is menu 25 currently active?
Yes (1) / No (0)
P16
Is menu 26 currently active?
Yes (1) / No (0)
Menu P2
¨
Setting time delays
Time delay values
sub-menu
description
Minimum Maximum General
reset
P21
(Optional)
Note:
only applies to systems
fitted with a corded switch
and a second switch in the
bathroom.
Delay timer for the bathroom switch (to
switch to high position).
• 'x' minutes after operating the bathroom
switch, the ComfoAir switches to the
high
setting
.
- Low voltage input
0 Min.
15 Min.
0 Min.
P22
(Optional)
Note:
only applies to systems
fitted with a corded switch
and a second switch in the
bathroom.
Overrun timer for the bathroom switch (to
switch to normal position).
• 'x' minutes after operating the bathroom
switch, the ComfoAir switches back to
the
normal
setting
.
- Low voltage input
0 Min.
120 Min.
30 Min.
P23
(Optional)
Note:
only applies to systems
fitted with a hardwired
3-position switch.
Overrun timer for ventilation position 3 (us-
ing a wired 3-position switch).
• If ventilation setting 3 (high) is switched
on briefly (< 3 sec), the ComfoAir will
switch to the
high
setting
for 'x' minutes
and then automatically returns to the
normal
setting
.
If any 3-position switch is operated during
this lagging time the ComfoAir will instant-
ly revert to the ventilation position as set
at that time.
0 Min.
120 Min.
0 Min.
P24
Filter warning
• 'x' weeks after cleaning the filters the
"
filter
dirty
" alert will reappear.
10 weeks 26 weeks
16
weeks