![Zehnder Rittling ComfoAir 350 Скачать руководство пользователя страница 15](http://html2.mh-extra.com/html/zehnder-rittling/comfoair-350/comfoair-350_instruction-manual_3296872015.webp)
11
System functions
3.2 Technical
speci
fi
cations
ComfoAir 350 nL (normal air volumes)
Position
Ventilation
capacity
Value
A
BSENT
S
ETTING
40 m3/h at 4 Pa
10
W
L
OW
S
ETTING
120 m3/h at 30 Pa
21
W
M
EDIUM
S
ETTING
180 m3/h at 65 Pa
44
W
H
IGH
S
ETTING
260 m3/h at 140 Pa
105
W
M
AXIMUM
350 m3/h at 240 Pa
243
W
Position
Ventilation
capacity
Value
A
BSENT
S
ETTING
40 m3/h at 4 Pa
0.08
A
L
OW
S
ETTING
120 m3/h at 30 Pa
0.17
A
M
EDIUM
S
ETTING
180 m3/h at 65 Pa
0.35
A
H
IGH
S
ETTING
260 m3/h at 140 Pa
0.81
A
M
AXIMUM
350 m3/h at 240 Pa
1.77
A
Electricity
Power supply
230/50 V/Hz
Cos.phi
0,50 - 0,60
Supply fan noise level (at 0 m)
Position
Ventilation
capacity
Value
A
BSENT
S
ETTING
40 m3/h at 4 Pa
36
db(A)
L
OW
S
ETTING
120 m3/h at 30 Pa
50
db(A)
M
EDIUM
S
ETTING
180 m3/h at 65 Pa
59
db(A)
H
IGH
S
ETTING
260 m3/h at 140 Pa
68
db(A)
M
AXIMUM
350 m3/h at 240 Pa
75
db(A)
Exhaust fan noise level (at 0 m)
Position
Ventilation
capacity
Value
A
BSENT
S
ETTING
40 m3/h at 4 Pa
39
db(A)
L
OW
S
ETTING
120 m3/h at 30 Pa
43
db(A)
M
EDIUM
S
ETTING
180 m3/h at 65 Pa
48
db(A)
H
IGH
S
ETTING
260 m3/h at 140 Pa
55
db(A)
M
AXIMUM
350 m3/h at 240 Pa
61
db(A)