1. General 

 
 

1.1 Application 

 
This operating instruction is valid for the jet pump and booster kit series WX and HWX. 
Non-compliance with the operating instructions - in particular with the safety instructions - as well as non-manufacturer modification or use 
of non-original spare parts will result in loss of guarantee coverage. The manufacturer accepts no liability for damage or injury resulting from 
incorrect use of the equipment. 
This product may also pass as any other electrical equipment in cause of lacking electrical supply. If you may get any damages thereby, 
please calculate in accordance to the use an emergency power generator, a second pump and/ or a network independent alarm system. As the 
manufacturer we will be after the buying at your disposal for near information. In cause of defects or damages please contact your retail 
trader. 
 
Manufacturer

ZEHNDER Pumpen GmbH 

 

 

Zwönitzer Straße 19 

 

 

08344 Grünhain-Beierfeld 

 
Product variations 

WX 3200 

HWX 3200 

HWX-E 3200 

HWX-P 3200 

 

 

WX 3800 

HWX 3800 

HWX-E 3800 

HWX-P 3800 

 

 

WX 5200 

HWX 5200 

HWX-E 5200 

HWX-P 5200 

 
Instruction last modified

March

 2012 

 
 

1.2 Queries and Ordering 

 
For queries and orders please contact your authorised retail trader. 
 
 

1.3 Technical data: 

 

Typ: 

WX 3200 

HWX 3200 

HWX-E 3200 
HWX-P 3200

 

WX 3800 

HWX 3800 

HWX-E 3800 
HWX-P 3800

 

WX 5200 

HWX 5200 

HWX-E 5200 
HWX-P 5200 

Power P

1

 

600 Watt 

1000 Watt 

1600 Watt 

Power P

2

 

350 Watt 

700 Watt 

1300 Watt 

Voltage 

230 V 
50 Hz 

230 V 
50 Hz 

230 V 
50 Hz 

Nominal current 

2.9 A 

4.4 A 

7.0 A 

Nominal speed 

2800 rpm 

2800 rpm 

2800 rpm 

max. capacity 

2900 l/h 

4000 l/h 

5000 l/h 

max. head 

41 m 

46 m 

60 m 

Outlet size 

G 1“ FT 

G 1“ FT 

G 1“ FT 

Inlet size 

G 1“ FT 

G 1“ FT 

G 1“ FT 

Sucking to max. 

8.5 m 

8.5 m 

8.5 m 

Cable length 

1.5 m 

1.5 m 

1.5 m 

Weight 

8.9 / 15.5 kg 

9.0 / 17.0 kg 

12.5 / 20.0 kg 

 
The pumps at series WX and HWX are applicable to a liquid temperature of max. 40° C. 
 
Materials: 
 
Pump housing: 

Stainless steel 

Impeller:     

Polyphenilenoxyd (PPO-GF) 

Ejector: 

   

Polyphenilenoxyd (PPO-GF) 

Motor shaft:   

Stainless steel 

Screws: 

   

Stainless steel 

Seals: 

   

NBR 

Mechanical seal:  Carbon/ceramic/NBR/ stainless steel 
Diaphragm vessel:  powder coated steel (HWX) resp. stainless steel (HWX- E) 
 
 

1.4 Areas of application 

 
The pumps will be used to deliver clean water out of wells, creeks and tanks for irrigation, domestic water supply, etc. The pumps are 
designed for pumping thin, clean, non-explosive liquids, not containing solid particles or fibres. The temperature of the pump liquid must not 
exceed 40°C. 
Sand and other abrasive parts may damage the seals or other parts of the pump (use a pre-filter). 

GB

Содержание WX Series

Страница 1: ...mpe de jardin Usine hydraulique de maison Baureihe Series S rie WX HWX Betriebsanleitung Operating Instructions Manuel d utilisation GB D WX 3200 HWX 3200 HWX E 3200 HWX P 3200 WX 3800 HWX 3800 HWX E...

Страница 2: ...Niederspannungsrichtlinie 93 68 EWG Anhang I im Sinne der EMV Richtlinie 92 31 EWG und 93 68 EWG im Sinne der Maschinenrichtlinie 2006 42 EG Hiermit erkl ren wir die ZEHNDER Pumpen GmbH Zw nitzer Str...

Страница 3: ...0 HWX P 3800 WX 5200 HWX 5200 HWX E 5200 HWX P 5200 Stand der Betriebsanleitung M rz 2012 1 2 Anfragen und Bestellungen Anfragen und Bestellungen richten Sie bitte an Ihren Fach bzw Einzelhandel 1 3 T...

Страница 4: ...itung durch das Personal voll verstanden wird Dieses Ger t ist nicht daf r bestimmt durch Personen einschlie lich Kinder mit eingeschr nkten physischen sensorischen oder geistigen F higkeiten oder man...

Страница 5: ...u kabels mit 230 V 50 Hz Wechselstrom Die Pumpe muss an eine Steckdose mit Erdung angeschlossen werden Pumpe nicht am Kabel ziehen oder tragen Die Pumpe darf mit einem besch digten Kabel nicht in Betr...

Страница 6: ...druck sollte mindestens 5 m 0 5 bar unter dem maximal erreichbaren Druck der Pumpe liegen Nach dem Ver ndern des Einschaltdruckes mu der Luftdruck im Membrandruckbeh lter entsprechend angeglichen werd...

Страница 7: ...abdichten Schnellkupplungen z B Geka mit Nachstellring zum Anpressen verwenden Saugh he zu gro max 8 5 m Saugh he verringern Saugschlauch zieht sich zusammen Spiralsaugschlauch verwenden aktivierter...

Страница 8: ...cksendungen an den Hersteller bitte nur frei und in der Originalverpackung an Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Zur Verk rzung der Reparaturzeit benennen Sie uns bitte...

Страница 9: ...ration of Conformity In accordance with EEC low voltage specifications 93 68 EWG app I In accordance with EMV Specifications 92 31 EWG und 93 68 EWG In accordance with 2006 42 EG We the following ZEHN...

Страница 10: ...orised retail trader 1 3 Technical data Typ WX 3200 HWX 3200 HWX E 3200 HWX P 3200 WX 3800 HWX 3800 HWX E 3800 HWX P 3800 WX 5200 HWX 5200 HWX E 5200 HWX P 5200 Power P1 600 Watt 1000 Watt 1600 Watt P...

Страница 11: ...onsible for their safety or received by it instructions how to use the device Children should be supervised to ensure that they do not play with the device 2 3 Dangers arising due to non compliance wi...

Страница 12: ...l protection this circuit breaker must trip out when earth fault current exceeds 30mA The pump must not drop in water and also not submersible Any operation of the pump next to a swimming pool or gard...

Страница 13: ...3 bar less than starting pressure of the unit Procedure Disconnect the power supply Open the tap that the system will be vented Remove the black cover at the rear of the tank and check the air pressur...

Страница 14: ...short intervals Diaphragm in vessel damaged Leakiness at the air valve Renew the diaphragm expendable part To less pre pressure in diaphragm vessel Produce the necessary air pressure see ch 4 Pressur...

Страница 15: ...nformit Dans le sens de la directive de basse tension EG 93 68 EWG annexe I Dans le sens la directive EMV 92 31 EWG et 93 68 EWG Dans le sens la directive 2006 42 EG Nous d clarons nous ZEHNDER Pompes...

Страница 16: ...08344 Gr nhain Beierfeld Tailles de construction WX 3200 HWX 3200 HWX E 3200 HWX P 3200 WX 3800 HWX 3800 HWX E 3800 HWX P 3800 WX 5200 HWX 5200 HWX E 5200 HWX P 5200 Etat du manuel d utilisation Mars...

Страница 17: ...Qualification de personnel et Formation Le personnel charg d utilisation d entretien d inspection et de montage doit avoir la qualification correspondante pour ces travaux Le ressort la comp tence et...

Страница 18: ...mites indiqu es dans la fiche signal 4ique ne peuvent en aucun cas t0e d pass es Un appareil travaillant automatiquement comme p ex une usine hydraulique de aison ne peut alement pas tr actionn de ma...

Страница 19: ...ou contre le sens des aiguilles d une montre peut augmenter ou diminuer la pression de d clenchement Revissez les couvertures d interrupteur pression branchez les fiches secteurs et contr lez les nouv...

Страница 20: ...nt exclues Les d rangements qui ne peuvent pas tre facilement r par s ne devraient tre limin s que par le service clients de Zehnder ou par des entreprises sp cialis es autoris es Les dommages qui son...

Страница 21: ...viron 2 bar voir point 4 Valve de pied perm able et ou pas existante Nettoyez resp installez la valve de pied Interrupteur pression en panne Renouvelez l interrupteur pression 4 La pompe ne d clenche...

Страница 22: ...dichtung kompl Mechanical seal Garniture tanche anneau glissant compl 16a 1 Geh usedichtung O ring 160x3 Joint de carter 17 7 8 Zylinderschraube M6x20 Screw M6x20 Vis de cylindre M6x20 20 1 3 Stopfen...

Страница 23: ...23 Ersatzteilzeichnung Spare parts drawing Dessin des pi ces de rechange...

Страница 24: ...24 ______________________________________________________________________________________________________ 2012 ZEHNDER Pumpen GmbH...

Отзывы: