![Zehnder Pumpen MICROBOY Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/zehnder-pumpen/microboy/microboy_operating-instructions-manual_3326891008.webp)
8
7. Disturbance,cause and elimination
-Disconnect from mains before working!
Disturbance
Cause
Elimination
1. Motor doesn`t turn
- no voltage
- connect plug
- check wall socket and fuse
- cutting edge is blocked
- remove cover,turn shaft clockwise
with screwdriver
-inform service at recurrence
- motor overloaded
- thermical overload stops motor,reset
-inform service at recurrence
- level-switch damaged
- use push botton to empty tank
and inform service
- control system damaged
- inform service
- motor defective
- inform service
2. motor turns,but no pumping
- outlet hose clogged or buckled
- clean or repair,testrun
- air vent of pump housing clogged
- remove hose and clean hose and
nipple
- check-valve installed in wrong
direction
- turn and test run
- ventilation of tank insufficient
- replace carbon filter
3. motor starts and stops
- ventilation clogged
- cleaning
- check-valve leak
- cleaning/exchange
- toilet flush defected
- check/repair
4. motor turns very noisy
- solid inside
- inform service.
5. alarm buzzer is activated
- max. level of liquid (reasons see
above)
- use push botton /inform service
Содержание MICROBOY
Страница 1: ...Wastewater lifting unit MICROBOY Operating instructions...
Страница 11: ...Appendix 1 Installation example Appendix 2 pump unit...
Страница 12: ...Appendix 3 and 4 overview complete lifting unit...
Страница 14: ......