7. Disturbance,cause and elimination  

 

-Disconnect from mains before working! 
 

 

 

 

 

Disturbance 

Cause 

Elimination 

 

 

 

 

 

 

1. Motor doesn`t turn 

- no voltage 

- connect plug 
- check wall socket and fuse 

 

 

 

 

- cutting edge is blocked 

- remove cover,turn shaft clockwise 
with screwdriver 
-inform service at recurrence 

 

 

 

 

- motor overloaded 

- thermical overload stops motor,reset  
-inform service at recurrence 

 

 

 

 

- level-switch damaged 

- use push botton to empty tank 
and inform service 

 

- control system damaged 

- inform service 

 

 

 

 

- motor defective 

- inform service 

 

 

 

2. motor turns,but no pumping 

- outlet hose clogged or buckled 

- clean or repair,testrun 

 

 

 

 

- air vent of pump housing clogged 

- remove hose and clean hose and 
nipple 

 

 

 

 

- check-valve installed in wrong 
direction 

- turn and test run 

 

 

 

 

- ventilation of tank insufficient 

- replace carbon filter 

 

 

 

 

 

 

3. motor starts and stops  

- ventilation clogged 

- cleaning 

 

 

 

 

- check-valve leak 

- cleaning/exchange 

 

 

 

 

 

 

 

- toilet flush defected 

- check/repair 

 

 

 

 

 

 

4. motor turns very noisy 

- solid inside 

- inform service. 

 

 

 

 

 

 

5. alarm buzzer is activated 

- max. level of liquid (reasons see 
above) 

- use push botton /inform service 

 

 

 

 

 

 

Содержание MICROBOY

Страница 1: ...Wastewater lifting unit MICROBOY Operating instructions...

Страница 2: ...ith safety advice 5 2 3 Safety conscious working 5 2 4 Safety information for owner operator 5 2 5 Safety information for maintenance inspection and fitting 5 2 6 Non manufacturer modification and spa...

Страница 3: ...R Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld declare that the wastewater lifting unit Microboy conforms to the following specifications EMV 92 31 EWG und 93 68 EWG EG low voltage specifi...

Страница 4: ...ng machines Manufacturer Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Instruction last modified January 2009 1 2 Technical data Power P1 0 65 kW Voltage U 230 V 50 Hz Nominal curre...

Страница 5: ...vironmental damage resulting from leaks of environmentally dangerous substances 2 3 Safety concious work These safety instructions as well as all national safety requirements and extra internal compan...

Страница 6: ...In case of a mal function the water level inside the tank will not decrease Another 30 seconds later the alarm buzzer will be activated For manual tests the pump can be started by pressing the switch...

Страница 7: ...about 6 12 seconds which depends on the lifting head During this time the tank will be emptied but the pump will work for another 15 seconds additionally to clean the cutting device This time can be c...

Страница 8: ...rm service control system damaged inform service motor defective inform service 2 motor turns but no pumping outlet hose clogged or buckled clean or repair testrun air vent of pump housing clogged rem...

Страница 9: ...1 320 1 Pressure hose MICROBOY 117604 1 330 2 Hose clip 20 32 117033 1 340 2 O ring 34 52x3 53 117034 1 350 4 Rubber foot 117035 1 360 2 Countersunk 3 5x9 5 117605 1 370 1 Non return valve valve 11705...

Страница 10: ...ssembly Switch device 3 0 1 Switching deviceMICROBOY E2 complete 117410 1 3 10 1 Switching box bonnet 117606 3 20 1 Switching box bottom section 117607 3 25 1 Circuit board MICROBOY E2 600 250 3 30 1...

Страница 11: ...Appendix 1 Installation example Appendix 2 pump unit...

Страница 12: ...Appendix 3 and 4 overview complete lifting unit...

Страница 13: ...overdrive time 5 s delay time 5 s overdrive time 15 s delay time 5 s overdrive time 10 s delay time 0 s overdrive time 5 s delay time 5 s overdrive time 20 s delay time 5 s overdrive time 10 s delay t...

Страница 14: ......

Отзывы: