1.4 Accessory 

 
This unit is ready for plug-in,complete with pressure connection,check-valve and all  necessary seals. 
 

2. Safety 

 
These instructions for use contain general information, which should be noted when setting up, using and serving 
the equipment. 
 

2.1  Marking of information in the instruction for use 
 

 

danger symbol in accordance with DIN 4844 - W9, 
 

 
for warnings regarding electrical current the following symbol is used 
 

  
   danger symbol in accordance with DIN 4844 - W8  

 

 

 

 
 

Instructions  which  must  be  complied  with  if  damage  to  the  equipment  and malfunctioning is to be avoided are 
indicated by the presence of the words 

Attention!

 or 

Important! - 

 

2.2   Dangerous arising due to non-compliance with safety advice 
 

Ignoring  of  security  instructions  can  lead  to  danger  of  personnel  and  to  the  environment  as  well  as  causing 
possible  damage  to  the  equipment.  Non-compliance  with  security  instructions  can  lead  to  the  loss  of  right  to 
claim damages. 
Non-compliance with security instructions can lead for example to: 
- Breakdown in important functions of the equipment 
- Breakdown in prescript methods for maintenance and upkeep 
- Danger of injury from electrical, mechanical or chemical sources 
- Environmental damage resulting from leaks of environmentally dangerous substances 

 
 
2.3  Safety concious work 
 

These  safety  instructions,  as  well  as  all  national safety requirements and extra internal company precautions or 
such laid down by the owner of the euipment must be observed. 
 
 

2.4  Safety information for the owner / operator 
 

Any parts of the machine which could de a possible source of hot or cold burns should be covered. 

 

Covering for moving parts (e.g. couplings) should not be removed while the machine is in use. 

 

Leak out of dangerous substances (e.g. explosives, poisons, hot liquids) have to be handled in such a way 

 

that no danger to persons or the environment may occur. Legal requirements must be observed. 

Danger resulting from electrical current must be prevented (For more information consult the  

 

specifications of the VDE or your local electricity board). 

 
 

2.5  Safety information for maintenance, inspection and fitting 
 

The owner must ensure that all maintenance, inspection and fitting work is carried out by qualified and authorised 
personel who are familiar with the operating instructions for equipment. In general all maintenance work must be 
carried out while the equipment is not in operation. The instructions for turning off the equipment contained in 
these operating instructions must be observed. 
Pumps and units which carry hazardous materials must be decontaminated. 

 

 

 

Содержание MICROBOY

Страница 1: ...Wastewater lifting unit MICROBOY Operating instructions...

Страница 2: ...ith safety advice 5 2 3 Safety conscious working 5 2 4 Safety information for owner operator 5 2 5 Safety information for maintenance inspection and fitting 5 2 6 Non manufacturer modification and spa...

Страница 3: ...R Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld declare that the wastewater lifting unit Microboy conforms to the following specifications EMV 92 31 EWG und 93 68 EWG EG low voltage specifi...

Страница 4: ...ng machines Manufacturer Zehnder Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Instruction last modified January 2009 1 2 Technical data Power P1 0 65 kW Voltage U 230 V 50 Hz Nominal curre...

Страница 5: ...vironmental damage resulting from leaks of environmentally dangerous substances 2 3 Safety concious work These safety instructions as well as all national safety requirements and extra internal compan...

Страница 6: ...In case of a mal function the water level inside the tank will not decrease Another 30 seconds later the alarm buzzer will be activated For manual tests the pump can be started by pressing the switch...

Страница 7: ...about 6 12 seconds which depends on the lifting head During this time the tank will be emptied but the pump will work for another 15 seconds additionally to clean the cutting device This time can be c...

Страница 8: ...rm service control system damaged inform service motor defective inform service 2 motor turns but no pumping outlet hose clogged or buckled clean or repair testrun air vent of pump housing clogged rem...

Страница 9: ...1 320 1 Pressure hose MICROBOY 117604 1 330 2 Hose clip 20 32 117033 1 340 2 O ring 34 52x3 53 117034 1 350 4 Rubber foot 117035 1 360 2 Countersunk 3 5x9 5 117605 1 370 1 Non return valve valve 11705...

Страница 10: ...ssembly Switch device 3 0 1 Switching deviceMICROBOY E2 complete 117410 1 3 10 1 Switching box bonnet 117606 3 20 1 Switching box bottom section 117607 3 25 1 Circuit board MICROBOY E2 600 250 3 30 1...

Страница 11: ...Appendix 1 Installation example Appendix 2 pump unit...

Страница 12: ...Appendix 3 and 4 overview complete lifting unit...

Страница 13: ...overdrive time 5 s delay time 5 s overdrive time 15 s delay time 5 s overdrive time 10 s delay time 0 s overdrive time 5 s delay time 5 s overdrive time 20 s delay time 5 s overdrive time 10 s delay t...

Страница 14: ......

Отзывы: