Configuration 

 

 

 

 

 

 

 

 

    

 

Binding & Sensor sensing Interval Setting 

Device will enter configuration mode from special sequence button press and hold.  

i) Make sure the device is in OFF state and wait for about 4 second.   

ii) Press the ON/OFF/configuration button for 4 times. (Interval must less than 2 secs) 

iii) Press and hold the button for the 5

th

 attempt. 

The status LED will blink GREEN and RED alternately upon successful enter configuration mode. If the 
status LED blink GREEN LED only, it fails to enter configuration but goes into normal ON mode. Kindly 
follow the steps again for another attempt. 

Once successfully enter the configuration mode, device 

will receive binding command.  It will automatically search for the nearest gateway and binding to 
it after exit and turn on the device

. Communication will begin upon a successful binding.  

During configuration mode, 10 secs timeout is implemented if no input is received.  Each press and 
release of button will increase a step in the sensor sensing interval setting as below: 

 

Table 2: Sensor Sensing Interval Setting 

Green Status LED Number of Blinking Times 

Sending Interval Setting 

5s 

10s 

15s 

30s 

60s 

Once the correct setting has been set, leave it for about 10 seconds to exit the configuration mode. 
The  device  will  back  into  OFF  state.  It  will  bind  to  nearest  gateway  and  follows  the  transmission 
interval setting after turned ON (after startup cycle finished).   

*Remark: WLX_BTZ1 model detects the change of state from its sensor input.  The change of state 
detected is sent out at every 15 minutes interval.  

 

Internal Memory Backup   

 

 

 

 

 

    

 

In the event when signal failed to send to a gateway, sensor data stores in the internal memory. These 
backup data will send again to gateway after network recovery. The maximum backup period depends 
on sending interval setting.  

Table 5: Maximum Backup Period 

Transmission Interval 

Maximum Backup Period*  

1 min 

7 days 

5 mins 

37 days 

10 mins 

75 days 

15 mins 

113 days 

Содержание WLX_BTZ1

Страница 1: ...ZEGGO WLX_BTZ1 REV 1 03 19 1 Future Integrated Data Evaluation Wireless Water Leakage Detector Model WLX_BTZ1 USER MANUAL...

Страница 2: ...V 1 03 19 2 DOCUMENT HISTORY Release No Date Revision Description 1 14 12 17 First Release Water Leakage Detector WLX_BTZ1 V1 0 2 16 04 19 System manual updated 3 14 10 19 Sensor Sensing Interval Info...

Страница 3: ...Zeggo s Gateway Easy Configuration and Installation 2 Years of Battery Life Internal storage to store during network failure Programmable sampling interval 1min 5min 10min 15min 30min Specification Ba...

Страница 4: ...very It is always a good practice to check that the device is ALIVE prior to the installation by turn ON OFF the device By pressing and holding the button for an interval blinking and colour of status...

Страница 5: ...gger repeatedly every turning on device from off state Mounting Avoid placing the device close to a metal object that may affect the transmission range Depends on installation location devices can be...

Страница 6: ...0 secs timeout is implemented if no input is received Each press and release of button will increase a step in the sensor sensing interval setting as below Table 2 Sensor Sensing Interval Setting Gree...

Страница 7: ...power to search the gateway and restore connection Both the battery level and signal level of the device can be view from Zeggo s portal It is recommended to replace the battery if battery level is le...

Страница 8: ...DING BUT NOT LIMITED TO DAMAGES FOR LOSS OF GOODWILL LOSS OF REVENUE OR PROFIT FAILURE OF OTHER EQUIPMENT TO WHICH PRODUCT IS CONNECTED WITH RESULTING FROM THE SUE OF PRODUCT RELATING TO WARRANTY SERV...

Страница 9: ...ZEGGO WLX_BTZ1 REV 1 03 19 9 Email support innoflex com sg www zeggo com sg Subject to change without notice Copyright 2017 Printed in Singapore...

Отзывы: