Configuration
Binding & Sensor sensing Interval Setting
Device will enter configuration mode from special sequence button press and hold.
i) Make sure the device is in OFF state and wait for about 4 second.
ii) Press the ON/OFF/configuration button for 4 times. (Interval must less than 2 secs)
iii) Press and hold the button for the 5
th
attempt.
The status LED will blink GREEN and RED alternately upon successful enter configuration mode. If the
status LED blink GREEN LED only, it fails to enter configuration but goes into normal ON mode. Kindly
follow the steps again for another attempt.
Once successfully enter the configuration mode, device
will receive binding command. It will automatically search for the nearest gateway and binding to
it after exit and turn on the device
. Communication will begin upon a successful binding.
During configuration mode, 10 secs timeout is implemented if no input is received. Each press and
release of button will increase a step in the sensor sensing interval setting as below:
Table 2: Sensor Sensing Interval Setting
Green Status LED Number of Blinking Times
Sending Interval Setting
1
5s
2
10s
3
15s
4
30s
5
60s
Once the correct setting has been set, leave it for about 10 seconds to exit the configuration mode.
The device will back into OFF state. It will bind to nearest gateway and follows the transmission
interval setting after turned ON (after startup cycle finished).
*Remark: WLX_BTZ1 model detects the change of state from its sensor input. The change of state
detected is sent out at every 15 minutes interval.
Internal Memory Backup
In the event when signal failed to send to a gateway, sensor data stores in the internal memory. These
backup data will send again to gateway after network recovery. The maximum backup period depends
on sending interval setting.
Table 5: Maximum Backup Period
Transmission Interval
Maximum Backup Period*
1 min
7 days
5 mins
37 days
10 mins
75 days
15 mins
113 days