Product Description   

 

 

 

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1:  WLX_BTZ1 Description 

 

Product Introduction   

 

 

 

 

 

 

    

 

WLX_BTZ1  Water  Leakage  Detector  functions  as  a  remote  transmitting  device.  A  gateway  with 
internet  access  must  within  the  range  that  the  sensor  reading  can  successful  transmit over to the 
gateway.  The  radio  range  between  transmitter  and  gateway  varies  significantly  based  on  the  site 
environment and surrounding objects (metal walls, furniture etc.). The compatible 

model of Zeggo’s

 

gateway for WLX_BTZ1 is: 

 

Zeggo Gateway, GWA_12Z1

 

 

Startup Operation 

 

 

 

 

 

 

 

    

 

Water Leakage Detector equipped with full battery at the time of delivery. It is always a good practice 
to check that the device is ALIVE prior to the installation by turn ON/ OFF the device. By pressing and 
holding the button for an interval, blinking and colour of status LED will indicate current ON/OFF status.  

Table 1: Turn On/Off Operation 

Button Press and Hold Period 

Status LED Behaviour 

ON/OFF Status 

> 3 second 

Flashing of Green LED 

Turn ON 

> 5 second 

Light up Red LED 

Turn OFF/ Go into Sleep 

 

A signal will send out to the gateway immediately after turned on accompany with blinking of LED 
indicating  the  operation  status. 

Green  LED  indicated  the  data  reading  is  successfully  sent  and 

received by gateway

. On the other hand, flash of 

Red LED shows a transmission failure or sensor 

fault

.  

Configuration Button (ON/OFF) 

Status LED (Green, Red Bicolour) 

M8 Connector (For External Probe) 

Flange 

Содержание WLX_BTZ1

Страница 1: ...ZEGGO WLX_BTZ1 REV 1 03 19 1 Future Integrated Data Evaluation Wireless Water Leakage Detector Model WLX_BTZ1 USER MANUAL...

Страница 2: ...V 1 03 19 2 DOCUMENT HISTORY Release No Date Revision Description 1 14 12 17 First Release Water Leakage Detector WLX_BTZ1 V1 0 2 16 04 19 System manual updated 3 14 10 19 Sensor Sensing Interval Info...

Страница 3: ...Zeggo s Gateway Easy Configuration and Installation 2 Years of Battery Life Internal storage to store during network failure Programmable sampling interval 1min 5min 10min 15min 30min Specification Ba...

Страница 4: ...very It is always a good practice to check that the device is ALIVE prior to the installation by turn ON OFF the device By pressing and holding the button for an interval blinking and colour of status...

Страница 5: ...gger repeatedly every turning on device from off state Mounting Avoid placing the device close to a metal object that may affect the transmission range Depends on installation location devices can be...

Страница 6: ...0 secs timeout is implemented if no input is received Each press and release of button will increase a step in the sensor sensing interval setting as below Table 2 Sensor Sensing Interval Setting Gree...

Страница 7: ...power to search the gateway and restore connection Both the battery level and signal level of the device can be view from Zeggo s portal It is recommended to replace the battery if battery level is le...

Страница 8: ...DING BUT NOT LIMITED TO DAMAGES FOR LOSS OF GOODWILL LOSS OF REVENUE OR PROFIT FAILURE OF OTHER EQUIPMENT TO WHICH PRODUCT IS CONNECTED WITH RESULTING FROM THE SUE OF PRODUCT RELATING TO WARRANTY SERV...

Страница 9: ...ZEGGO WLX_BTZ1 REV 1 03 19 9 Email support innoflex com sg www zeggo com sg Subject to change without notice Copyright 2017 Printed in Singapore...

Отзывы: