background image

 

ZEGGO THA_C1Z1 

REV. 1 03/19 

 

 

The  battery  life  is  purely  indicative  as  it  mainly  depends  on  transmission  interval  setting,  installation 
environment condition and quality of wireless connection. If the device fails to communicate with the 
gateway, it will consume more power to search the gateway and restore connection.  

Both the battery level and signal level of the device can be view from Zeggo’s portal.  It is recommended 

to  replace  the  battery  if 

battery  level  is  less  than  20%

.  The  suggested  signal  percentage  for 

a  stable 

connection is >40%

 to take care the moving object or addition of object in between signal path.     

 

Information Regarding Product Disposal 

 

 

    

 

This  product  contains  Lithium  Thionyl  Chloride  Battery.  There  are  a  fire,  explosion,  and  severe  burn 
hazard. Do not burn or expose the battery to high temperatures. Do not recharge, crush, disassemble, or 
expose the contents to water. Properly dispose of used batteries according in accordance with applicable 
regulations in country. A disposal service could offer upon request.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание THA C1Z1

Страница 1: ...ZEGGO THA_C1Z1 REV 1 03 19 1 Future Integrated Data Evaluation Wireless Humidity and Temperature Transmitter Model THA_C1Z1 USER MANUAL...

Страница 2: ...ZEGGO THA_C1Z1 REV 1 03 19 2 DOCUMENT HISTORY Release No Date Revision Description 1 28 03 19 First Release Humidity Transmitter THA_C1Z1 V1 0 2 16 04 19 System manual updated...

Страница 3: ...15 4 Radio Transmission to Zeggo s Gateway Easy Configuration and Installation 2 Years of Battery Life Internal storage to store during network failure Programmable sampling interval 1min 5min 10min...

Страница 4: ...elivery It is always a good practice to check that the device is ALIVE prior to the installation by turn ON OFF the device By pressing and holding the button for an interval blinking and colour of sta...

Страница 5: ...OFF configuration button for 4 times Interval must less than 2 secs iii Press and hold the button for the 5th attempt The status LED will blink GREEN and RED alternately upon successful enter configur...

Страница 6: ...ate Green Red Slow Clear Internal Memory Reset Time 30 secs Alternate Green Red Fast Reset Battery Counter Percentage Software Calibration Device will enter configuration mode from special sequence bu...

Страница 7: ...d ON Internal Memory Backup In the event when signal failed to send to a gateway the temperature data stores in the internal memory These backup data will send again to gateway after network recovery...

Страница 8: ...ommended to replace the battery if battery level is less than 20 The suggested signal percentage for a stable connection is 40 to take care the moving object or addition of object in between signal pa...

Страница 9: ...OF REVENUE OR PROFIT FAILURE OF OTHER EQUIPMENT TO WHICH PRODUCT IS CONNECTED WITH RESULTING FROM THE SUE OF PRODUCT RELATING TO WARRANTY SERVICE OR ARISING OUT OF ANY BEACH OF THIS LIMITED WARRANTY E...

Отзывы: