background image

 

6.12

 

G

ENERATOR

 ................................................................................................................... 12

 

6.13

 

V

IDEO OUTPUT

 ............................................................................................................... 12

 

6.14

 

C

ONNECT TO 

PC ............................................................................................................. 12

 

6.15

 

C

URSOR

 ........................................................................................................................ 13

 

7

 

MENU INTRODUCTION .......................................................... 13

 

7.1

 

C

HANNEL

 ........................................................................................................................... 13

 

7.2

 

M

EASUREMENT

 ................................................................................................................... 13

 

7.3

 

T

RIGGER

 ............................................................................................................................ 14

 

7.4

 

D

ISPLAY

 ............................................................................................................................. 14

 

7.5

 

A

UX

 .................................................................................................................................. 14

 

7.6

 

S

ETTINGS

 ........................................................................................................................... 15

 

 

 

1  Safety Precautions 

Learn about the following safety precautions to avoid injury and prevent damage 

to this product or any products connected to it. To avoid possible danger, be sure to 
use this product as specified.

   

 

Only authorized personnel should perform maintenance procedures.

 

 

Avoid  fire  and  personal  injury

Use  the  probe  correctly  and  ensure  that  the 

measured voltage does not exceed the maximum withstand voltage.

 

 

Connect  the  probe  correctly.

Before  measuring  voltage  greater  than  40V,  please 

switch the probe to the 10X position first.

 

 

Charge  the  battery  correctly.

The  ideal  charging  voltage  is  5V,  and  the  highest 

cannot be higher than 6V.

 

 

Do not operate in a humid environment.

 

 

Keep the surface of the product clean and dry.

 

 

 

Содержание DSO1511G

Страница 1: ...ZEEWEII DSO1511G User s Manual Designed by zeeweii DSO1511G HANDHELD OSCILLOSCOPE...

Страница 2: ...enerator When it is closed no display Time base which means the time of a grid in the horizontal direction Click the ns and s buttons to adjust Coupling DC AC Probe attenuation x1 x10 x100 Vertical se...

Страница 3: ...r buttons Power OK short press Press and hold Power and short press Ok to switch the trigger edge rising or falling Power OK long press Press and hold Power and long press Ok to switch the trigger mod...

Страница 4: ...VITY 7 3 2 VERTICAL POSITION 8 4 HORIZONTAL SYSTEM 8 4 1 TIME BASE 8 4 2 HORIZONTALLY MOVING WAVEFORM 8 5 TRIGGER SYSTEM 9 5 1 TRIGGER LEVEL 9 5 2 TRIGGER POSITION 9 6 OPERATION GUIDE 10 6 1 POWER 10...

Страница 5: ...danger be sure to use this product as specified Only authorized personnel should perform maintenance procedures Avoid fire and personal injury Use the probe correctly and ensure that the measured vol...

Страница 6: ...thout overshoot 3 Adjust the horizontal and vertical scales of the oscilloscope so that the waveform is displayed stably at a suitable position on the screen 4 Use a screwdriver to rotate the adjustab...

Страница 7: ...gh voltage signal otherwise the high voltage may break down the internal circuit of the oscilloscope 2 4 3 High bandwidth Because the 1X probe has a large input capacitance the bandwidth of the probe...

Страница 8: ...observing how many grids a waveform period occupies For example the current time base is 500us and one cycle of the signal occupies 2 grids so the signal period is 1ms 1KHz The oscilloscope time base...

Страница 9: ...In edge trigger mode a trigger condition occurs only when the waveform crosses the trigger level To adjust the trigger level 1 Change Trigger Level to Manual in the menu 2 Method 1 Press and hold the...

Страница 10: ...rging current is about 700ma The LED at the bottom of the charging process is bright red and the led turns green when fully charged 6 3 Vertical Time base scale Press the mV and V buttons to adjust th...

Страница 11: ...s sampling is not completed until there is a waveform trigger Operation method Click the xKey button and select Single 6 9 Reference waveform The reference waveform is that the waveform of the previou...

Страница 12: ...square wave signal may show small horizontal jitter 6 13 Video output The 3 5mm headphone jack at the bottom can output AV analog video signal which can be connected to a TV or projector Open Menu Set...

Страница 13: ...ltage of the dotted line below dY Y1 Y2 is the voltage difference between the two dotted lines 7 Menu introduction Click the Menu button to open close the menu 7 1 Channel The channel menu includes tw...

Страница 14: ...rigger mode is Normal you should use the manual option Under this option the trigger level can be manually adjusted by the user 7 4 Display In this menu you can set persistence roll mode and brightnes...

Страница 15: ...after no button operation 2 You can choose whether to turn on the sound 3 Language selection Chinese or English 4 In this menu long press the ns button to enter the usb connection state long press s...

Страница 16: ...16...

Отзывы: