ZvBox
®
170
Configuration
Manual
Page
9
www.zeevee.com
Rev
1.0
Syntax
SET
CABLE
PLAN
{
standard
|HRC
|
IRC}
You
can
set
the
cable
plan
(Standard,
HRC
or
IRC)
to
be
used.
For
best
results
during
the
scan,
connect
ZvBox®
to
the
cable
plant
using
the
same
coax
cabling
connection
that
you
would
use
to
connect
an
HDTV.
Cable
Scan
ZvBox®
products
contain
a
very
powerful
feature
to
aid
the
installer–
a
built
‐
in
cable
spectrum
analyzer.
When
asked,
ZvBox®
will
stop
transmitting,
analyze
every
RF
channel
on
the
cable
and
report
the
result.
The
report
shows
if
a
channel
is
open
or
occupied,
and
if
occupied,
if
the
channel
is
Analog
or
Digital.
Syntax
START
CABLE
‐
SCAN
RF
frequencies
on
the
coax
cabling
are
scanned
from
lowest
number
to
highest.
The
scan
cannot
be
interrupted
once
started.
Example:
(some
results
omitted
to
save
space)
START
CABLE
‐
SCAN
Determining
cable
plan
RF
2:
Open
RF
3:
Digital
RF
4:
Analog
…
RF
135:
Open
SCAN
COMPLETED
‐
Hit
NEXT
Show
Last
Cable
Scan
Results
ZvBox®
remembers
the
results
of
the
last
cable
scan
performed.
This
command
shows
the
results.
The
first
line
shows
the
cable
‐
plan
type
that
was
determined
(standard,
HRC,
or
IRC).
Syntax
SHOW
SCAN
RESULTS
Example:
SHOW
SCAN
RESULTS
Hit
+
‐
to
scroll
Cable
‐
plan
STD
Open
2
3
4
5
6
7
Open
8
9
10
11
…
Digital
12
13
14
15
…
Analog
16
17
18
19