![zeeltronic PDCI-24V Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/zeeltronic/pdci-24v/pdci-24v_user-manual_3275676005.webp)
- 5 -
Important!
To avoid wrong processing, don't make unreasonable curve course.
Every time you make any changes to ignition curve, it is automatically saved to number #0.
Later you can save it to any other number #1 or #2.
Ignition Map Example:
5.2.
Change NUMBER OF IGNITION CURVE POINTS
Move to
Nr. of Points
with pressing + or - and then press enter .
Now you can select number of ignition points, with pressing + or - and then press enter .
5.3.
Change PARAMETERS OF IGNITION CURVE POINT
Move to point you want to change, with pressing + or - and then press enter .
Now you can change rev point with pressing + or - (in 100 rpm steps) and then press enter .
Now you can change advance angle with pressing + or - (in 0.1deg steps) and then press
enter .
6.
ADVANCE
With this setting is possible to advance, or retard whole ignition map on both ignition coil
outputs. When setting is positive, then ignition map is advanced and when setting is negative,
than ignition map is retarded. Ignition map is unchanged, with setting
0.0deg
.
Enter menu and move to
Advance
, with pressing + or - and then press enter .
Now you can set advance with pressing + or - (in 0.1deg steps) and then press enter .