- 4 -
Important!
To avoid wrong processing, don't make unreasonable curve course.
Every time you make any changes to ignition curve, it is automatically saved to number #0.
Later you can save it to any other number #1 or #2.
Curve Example with six curve points:
5.1.
SET IGNITION MAP (if TPS enabled)
Three ignition curves must be programmed for different TPS positions.
PDCI
does not only
switch between ignition curves, but also interpolate 3D map for all TPS positions above 33%.
Enter
Set Ign.
menu and move to
Set
Ignition Map
with pressing + or - and then press enter.
...you entered submenu for selecting ignition curve.
Submenu organisation:
Nr. of Points
- number of ignition curve points (from 4 to 12)
Curve 0-33%
- ignition curve from 0 to 33% TPS
Curve 66%
- ignition curve for 66% TPS
Curve 100%
- ignition curve for 100% TPS
Exit
- exit submenu