zeeltronic PDCI-20V Скачать руководство пользователя страница 14

 

 

- 14 -

32. MONITORING 

 
Connect 

programmer

 to 

PDCI 

and wait few seconds for activation of 

programmer. 

Fist 

information displayed on the 

programmer

 is software version. 

 
With 

programmer

 you can watch revs, calculated advance ignition angle, TPS 

position...depends on setting in the menu. 
 

 
Information!

 

You can connect or disconnect 

PDCI 

unit from 

programmer

 any time you want, without any 

harm. It is not important, if motor running or not and if power supply is connected or not.    
 

Important!

 

Do not use too much force when connecting or disconnecting 

programmer

 unit! 

 

33. ERROR 

REPORTS 

 

PVerr 1 

– position sensor error or servo motor disconnected  

PVerr 2 – 

servo motor error (short connection) 

 

Содержание PDCI-20V

Страница 1: ...ting spark energy already at 7Volts power supply two isolated input pickup two independent ignition coil outputs individual advance retard of each output store and load function for two ignition maps...

Страница 2: ...programmer and then press enter With pressing or you can move through menu and with pressing enter you can choose You can exit menu with choosing Exit 2 MENU ORGANISATION Set Ign set ignition paramete...

Страница 3: ...g deactivating external switch for selecting PV curve Exit 3 LOAD IGN MAP Enter Set Ign menu and move to Load Ign Map with pressing or and then press enter Now you can select number of saved ignition...

Страница 4: ...s must be programmed for different TPS positions PDCI does not only switch between ignition curves but also interpolate 3D map for all TPS positions above 33 Enter Set Ign menu and move to Set Ignitio...

Страница 5: ...NT Move to point you want to change with pressing or and then press enter Now you can change rev point with pressing or in 100 rpm steps and then press enter Now you can change advance angle with pres...

Страница 6: ...p is unchanged with setting 0 0deg Enter menu and move to Advance with pressing or and then press enter Now you can set advance with pressing or in 0 1deg steps and then press enter 9 GEAR SHIFT LIGHT...

Страница 7: ...tic angle with pressing or in 0 1deg steps and then press enter More information s about static angle you can find in section 31 13 COMPENSATION It is compensation of signal delay from pickup to spark...

Страница 8: ...90 TPS Power jet is switched on when revs are between 8000 10000rpm and throttle position is between 70 90 otherwise power jet is switched off 14 1 POWER JET 1 ON RPM Enter Set Ign menu and move to P...

Страница 9: ...Jet 2 or Duty Solenoid Duty solenoid is used for adjusting A F ratio on some carburettors Enter Solenoid Output menu and move to Output type with pressing or and then press enter Now you can change s...

Страница 10: ...sing enter or exit calibration with pressing Displayed number should be between 0 and 500 18 Set TPS open 100 if TPS enabled For correct operation TPS open position must be calibrated Enter Set Ign me...

Страница 11: ...enu and move to Load PV Curve with pressing or and then press enter Now you can select number of PV curve with pressing or and then press enter 23 SAVE PV CURVE Enter Set PV menu and move to Save PV C...

Страница 12: ...If deviation is too low then servo motor won t be stabile it will always search for calculated position in small movements Default setting is 5 and should meet in most cases 26 CLOSE POSITION Max clo...

Страница 13: ...essing or and then press enter Now you can enable or disable power up test with pressing or and then press enter 30 PV CURVE SW Enabling or disabling PV curve switch for changing PV curves while ridin...

Страница 14: ...S position depends on setting in the menu Information You can connect or disconnect PDCI unit from programmer any time you want without any harm It is not important if motor running or not and if powe...

Отзывы: