background image

 

Dual-Laser Omnidirectional Scanner

 

U

SER

M

ANUAL

 

6.)

 

Use a power +5V DC external power supply to the power jack on the interface cable if the 
external power is required. 

7.)

 

Switch on your computer system. 

8.)

 

Adjust the scanner’s parameters by scanning the appropriate labels in programming guide, 
if necessary. 

 

Keyboard connection of

 PC or HOST system

 

Figure 7 

 
 

3.  USB interface 
 

Connect USB cable to a host. The scanner automatically detects a USB host and defaults to the 
HID keyboard interface type. 
 
1.)

 

Make sure that the power of your computer system is switched off. 

2.)

 

Plug the interface cable modular into the scanner port until a firm 

“Click” sound is heard. 

3.)

 

Connect the other end of the interface cable into the USB port on the host. 

4.)

 

Use a power +5V DC external power supply to the power jack on the interface cable, if the 
external power is required. 

5.)

 

Switch on your computer system. 

6.)

 

Adjust the scanner’s parameters by scanning the appropriate labels in programming guide, 
if necessary. 

 

USB connection of

 PC system

 

Figure 8 

 
 

Содержание Z-6070 Series

Страница 1: ...SYMBOL 100 PIRY ins zebex OPTICON cino T S C Honeywell SHENZHEN XIN HUA HAN SCIENCE AND TECHNOLOGY CO LTD 3007 11 0755 83981612 0755 83981617 0755 83558013 7106 www scanshop cn 400 609 8831 HR1030 RC...

Страница 2: ...i...

Страница 3: ......

Страница 4: ...erence Operation of this equipment in a residential area can cause interference to radio or television reception This can be determined by turning the equipment off and on The user is encouraged to tr...

Страница 5: ...ranscribed or translated into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written consent and auth...

Страница 6: ...Template Installation if required 6 Connecting the Scanner 7 Replacing the Interface Cable 10 How to Scan 11 Single Line Mode 13 Sleep mode 14 LED and Beeper Indications 15 Changing Beeper Volume Usi...

Страница 7: ......

Страница 8: ...are decode technology to provide real time decode capability to effectively shorten customer transaction time Its broad scan field could effectively facilitate scanning barcodes on products in all kin...

Страница 9: ...Hands free scanner B Adjustable stand optional Communication and power link Cable according to order Keyboard wedge cable for PC AT PS2 DB 9 female connector RS232 cable DTE pin out DB 9 female conne...

Страница 10: ...er tone selection When the scanner is sitting in the adjustable stand press down this button for 5 seconds and it will automatically change the beeper volume LED A red LED indicates the scanner is rea...

Страница 11: ...interface cable to the host refer to your host manual to locate the correct port 3 Plug the power supply into the power jack on the interface cable 4 Plug the other end of the power supply into an AC...

Страница 12: ...he buzzer gives 3 string long beep sound When the self test is completed the LED status will return red 5 Present the test barcode below to the scanner If the scanner is functioning properly it will i...

Страница 13: ...ter top The base template can be mounted on a flat counter top by the following steps 1 Put the template at where you want to fix the stand 2 Screw down to mount the template onto the counter M4 or sc...

Страница 14: ...o the power jack on the interface cable if the RS 232C port of computer system does not supply power 5 Switch on your computer system 6 Adjust the scanner s parameters if necessary by scanning the app...

Страница 15: ...r automatically detects a USB host and defaults to the HID keyboard interface type 1 Make sure that the power of your computer system is switched off 2 Plug the interface cable modular into the scanne...

Страница 16: ...l power supply to the power jack on the interface cable if the external power is required 5 Switch on your computer system 6 Adjust the scanner s parameters by scanning the appropriate labels in progr...

Страница 17: ...be field replaceable Replacement cable can be obtained from an authorized distributor To replace the cable the following steps should be followed 1 Make sure that the power of your computer system is...

Страница 18: ...10 Figure 10 Scanning Operation The scanner supports two scanning patterns Multi line scanning Single line scanning Multi Line Mode In this mode the front scan window is in multi line scan pattern an...

Страница 19: ...Dual Laser Omnidirectional Scanner 12 USER S MANUAL Figure 12 scanner in the stand Figure 13 With stand Figure 14 Without stand Figure 15 Presentation scanning Figure 16 Sweep scanning...

Страница 20: ...s clerks can switch it to single line scan option simply by pressing one button 1 Pick up the scanner 2 Press and then release the side button left or right and a line pattern would appear It allows y...

Страница 21: ...o wake up the unit simply present an object to the scanner window or press the button at the sides The scanner takes 2 steps to enter the sleep mode Firstly laser switches off after 10 minutes secondl...

Страница 22: ...gramming mode Flash Red light The scanner enters the sleep mode Steady Red Green light This indicates the scanner has a motor or laser failure For motor failure also with a periodic beeper is heard Re...

Страница 23: ...he changed the volume setting use the programming guide to set the changes Maintaining the Scanner This laser scanner rarely needs any maintenance Only an occasional cleaning of the scanner window is...

Страница 24: ...d averaged over 10 seconds Do not attempt to remove the protective housing of the scanner as unscanned laser light with a peak output up to 0 8mW would be accessible inside Laser Light Viewer The scan...

Страница 25: ...Dual Laser Omnidirectional Scanner 18 USER S MANUAL APPENDIX TECHNICAL SPECIFICATION...

Страница 26: ...nition for the scanner port and the connector to be used for the port are as following Pin out Configuration Function PIN Keyboard Wedge RS 232C Wand emulation 1 DC 5V input 2 Keyboard Clock N C N C 3...

Страница 27: ...rs LED Two color LED green red Beeper Operation Programmable tone and beep time System Interfaces Keyboard RS 232C USB1 1 Wand Physical Height 181 5mm Depth 115 0mm Width 100 0mm Weight 245g stand exc...

Страница 28: ...Dual Laser Omnidirectional Scanner 21 USER S MANUAL Dimensions...

Страница 29: ...wake up the scanner or use the wake protocol The LED remains red and green Possible failure of the scanning safeguard circuit Disconnect the scanner from its power source immediately and contact your...

Отзывы: