background image

Start of Configuration

UPC/EAN/JAN PARAMETERS SETTING (Cont’d)

2 Characters

2 or 5 Characters

FORCE UPC-E TO UPC-A FORMAT

Yes

No

FORCE UPC-A TO EAN-13 FORMAT

Yes

No

TRANSMIT UPC-A LEADING CHARACTER

Yes

No

28

TRANSMIT UPC-A CHECK DIGIT

Yes

No

TRANSMIT UPC-E LEADING CHARACTER

Yes

No

TRANSMIT UPC-E CHECK DIGIT

Yes

No

TRANSMIT EAN-13 CHECK DIGIT

Yes

No

End of Configuration

29

Содержание Alpha-50 series

Страница 1: ...ZBX99030301 P N MUL 53221 04 DO NOT STARE INTO BEAM LASER LIGHT CAUTION 670nm LASER DIODE 1 0mW MAX OUTPUT IEC 825 1 1993 CLASS I US 21 CFR 1040 CLASS IIa LASER PRODUCT...

Страница 2: ...y Taipei Taiwan R O C Tel 886 2 2218 2018 Fax 886 2 2218 8670 Web site www zebex com tw E mail mail zebex com tw ZEBEX INDUSTRIES INC Auto ID Division 1F 531 Chung Cheng Road Hsin Tien City Taipei Tai...

Страница 3: ...Machines Corp IBM PS 2 is a product of International Business Machines Corp NEC is a registered trade mark of NEC Corporation All other registered trade marks are registered companys property ZEBEX i...

Страница 4: ...per Tone Selection 10 Bar Code ID Selection 11 RS 232C Serial Communication Parameters Setting Handshaking Protocol 13 ACK NAK Response Time Setting 14 Baud Rate 15 Data Bit 15 Stop Bit 15 Parity Sett...

Страница 5: ...to the scanner If a keyboard emulation type scanner is used with a IBM PC XT AT PS 2 or any fully compatible computers power will be drawn from the keyboard port No external power adapter is required...

Страница 6: ...UPC E bar code identifier code E UPC A bar code identifier code A EAN 13 bar code identifier code F EAN 8 bar code identifier code FF Codabar bar code identifier code N Code 128 bar code identifier c...

Страница 7: ...it Disable Chinese Post Length 10 16 digits Code Check digit Transmit Format All Addendum Disable UPC E UPC A Disabled UPC EAN JAN UPC A leading digit Transmit UPC A check digit Transmit UPC E leading...

Страница 8: ...sed and double reading for the same bar code is permitted The scanner will turn off when the trigger switch is released 6 Without any scanning the unit will enter a standby mode To reactivate the unit...

Страница 9: ...cutive messages This delay will be added before each data transmission Start of Configuration label and then select the appropriate delay time to activate this feature None 100mSec 500 mSec 1 Second 8...

Страница 10: ...e buzzer after successful reading Medium Low High Disable For Alpha 70 only Medium and disable setting available 10 SOUND DURATION long 120ms Medium 50ms Short 20ms Very short 5ms BAR CODE IDENTIFIER...

Страница 11: ...nfiguration label 2 Scan Bar code identifier setting code label 3 Scan the new code mark from ASCII table max two digits For example if AB want for code mark then scan A and B 4 Scan Set label 5 Scan...

Страница 12: ...ration HANDSHAKING PROTOCOL Cont d ACK NAK Xon Xoff ACK NAK RESPONSE TIME SETTING 300 mSec 2 Sec 500 mSec 3 Sec 1 Sec 5 Sec 14 BUAD RATE 19200 9600 4800 2400 1200 600 DATA BIT 7 8 STOP BIT 1 2 End of...

Страница 13: ...ESSAGE TERMINATOR FOR RS 232C TYPE ONLY None CR LF CR LF H Tab 16 STX ETX EOT KEYBOARD EMULATION PARAMETERS SETTING KEYBOARD TYPE SELECTION IBM AT PS 2 30 80 IBM 5550 IBM 5295 Terminal IBM XT IBM 3477...

Страница 14: ...9801 IBM 3196 Terminal APPLE MAC II MOS SYS PS2 30 56 IBM 3477 Terminal without break code NEC 5200 Note The configuration of the items with asterisk is optional 18 KEYBOARD LANGUAGE SELECTION USA UK...

Страница 15: ...erface for these IBM terminal read the correct key transmission code ON OFF 20 FUNTION KEY ACTIVE ON OFF FOR IBM AT USE Function keys can be concatenated with input data as header and or trailer See p...

Страница 16: ...2 of 5 Disable Chinese post code Enable Chinese post code Disable Code 128 Enable Code 128 Disable MSI Enable MSI Disable 22 Code 93 Enable Code 93 Disable IATA Enable IATA Disable EAN 128 Enable EAN...

Страница 17: ...GIT Calculate and Transmit Calculate but not Transmit NO CONCATENATION Enable Disable 24 INTERLEAVED 2 OF 5 PARAMENTERS SETTING Examples Felting length 4 to 8 digits LENTGTH Ssan 1 Start of configurat...

Страница 18: ...f configuration Min 0 4 set max 0 8 set End of configuration CHECK DIGIT NO Calculate and Transmit Calculate but not Transmit UPC EAN JAN PARAMETERS SETTING FORMAT All 26 EAN 8 or EAN 13 UPC A and EAN...

Страница 19: ...cters FORCE UPC E TO UPC A FORMAT Yes No FORCE UPC A TO EAN 13 FORMAT Yes No TRANSMIT UPC A LEADING CHARACTER Yes No 28 TRANSMIT UPC A CHECK DIGIT Yes No TRANSMIT UPC E LEADING CHARACTER Yes No TRANSM...

Страница 20: ...ON No A B C D DC1 DC4 a t b n c d e CONCATENATION Enable Disable 30 CODE 128 PARAMETERS SETTING FNC 2 CONCATENATION Enable Disable CHECK DIGIT No Calculate and Transmit Calculate but not Transmit UCC...

Страница 21: ...x 0 8 set End of configuration Double Check digit Calculate but not Transmitted No 32 MSI PLESSY PARAMETERS SETTING Cont d Calculate but only first one Transmitted Calculated and both Transmitted Sing...

Страница 22: ...G CODE 39 LENGTH SETTING MAX MIN CODE 93 LENGTH SETTING MAX MIN 34 CODE 128 LENGTH SETTING MAX MIN Set CODABAR LENGTH SETTING MAX MIN ISBN ISSN CONVERSION The function convents the UPC EAN codes appea...

Страница 23: ...G EMULATION SPEED SELECTION Low Medium Normal High Higher EMULATION DATA OUTPUT SELECTION The decoded data output logic level can be set to befit the external decoder Black High Black Low 36 WNAD EMUL...

Страница 24: ...N X 18 H 3D EM Y 19 I 3E SUB Z 1A J 3F ESC A 1B V 40 FS B 1C A A 41 GS C 1D B B 42 RS D 1E C C 43 US E 1F D D 44 SP SP 20 E E 45 A 21 F F 46 B 22 G G 47 C 23 H H 48 D 24 I I 49 38 APPENDIX A CODE 39 F...

Страница 25: ...W 17 Backspace H 08 F8 X 18 TAB I 09 F9 Y 19 Enter num J 0A F10 Z 1A Right K 0B F11 A 1B PgUp L 0C F12 B 1C Enter M 0D ESC C 1D PgDn N 0E Ctl L D 1E shift O 0F Alt L E 1F 5 num P 10 CURSOR PAD WORK AT...

Страница 26: ...uration LF Enter num DLE 5 num VT Right DC1 F1 FF PgUp DC2 F2 CR Enter DC3 F3 SO PgDn DC4 F4 SI shift L NAK F5 42 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE SYN F6 GS ESC ETB F7 RS Ctl L CAN F8 US A...

Страница 27: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration 0 1 44 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE 2 3 4 5 6 7 8 9 A End of Configuration 45...

Страница 28: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration B I C J D K E L F M G N H O 46 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE P W Q X R Y S Z T U V End of Configuration 47...

Страница 29: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration e _ f g a h b i c j d k 48 APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE l s m t n u o v p w q x r y End of Configuration 49...

Страница 30: ...APPENDIX B CODE 39 FULL ASCII BAR CODE TABLE Start of Configuration z DEL End of Configuration 50...

Отзывы: