6
CAUTION
1. The high-pressure outlets (HP Ports) are dis-
tinctly larger than the low-pressure outlets. Only
devices with fittings, hoses and components
designed for the full tank pressure that the regu-
lator will be mounted on, such as Submersible
Pressure Gauges, are to be installed in these
ports.
2. During installation, the O-ring hose fittings
will seal with hand-tight pressure, but may come
loose during use if not tightened carefully with
a small wrench. Proper torque for the hose fit-
tings is 40-45 in lbs. (4.5 - 5 joules) Excessive
tightening will not help the seal and may damage
the parts (see DEMA Guidelines No. 101, Low
Pressure Hose Installation Caution Statement;
ANSI American National Standard for Underwater
Safety, paragraph 9.3.1).